[0] *
Not linked
[1]
Set-up 1
[2]
Set-up 2
[3]
Set-up 3
[4]
Set-up 4
0-13 Readout: Linked Set-ups
Array [5]
Range:
Function:
0 N/A*
[0 - 255 N/A]
View a list of all the set-ups linked by means of par.0-12
. The parameter has
one index for each parameter set-up. The parameter value displayed for each index represents
which setups are linked to that parameter setup.
Index
LCP value
0
{0}
1
{1,2}
2
{1,2}
3
{3}
4
{4}
Table 3.2: Example: Set-up 1 and Set-up 2 are linked
0-14 Readout: Prog. Set-ups / Channel
Range:
Function:
0 N/A*
[-2147483648 - 2147483647 N/A] View the setting of par.0-11
for each of the four different communication
channels. When the number is displayed in hex, as it is in the LCP, each number represents one
channel.
Numbers 1-4 represent a set-up number; ‘F’ means factory setting; and ‘A’ means active set-up.
The channels are, from right to left: LCP, FC bus, USB, HPFB1.5.
Example: The number AAAAAA21h means that the FC bus selected Set-up 2 in par.0-11
, the LCP selected Set-up 1 and all others used the active set-up.
3.2.4 0-2* LCP Display
Define the variables displayed in the Graphical Local Control Panel.
NB!
Please refer to par.0-37
for information on how to write display
texts
0-20 Display Line 1.1 Small
Option:
Function:
Select a variable for display in line 1, left position. Default setting is application dependent.
[0]
None
No display value selected
[37]
Display Text 1
Enables an individual text string to be written, for display in the LCP or to be read via serial com-
munication.
[38]
Display Text 2
Enables an individual text string to be written, for display in the LCP or to be read via serial com-
munication.
ADAP-KOOL
®
Drive Programming Guide
3 Parameter Description
MG.11.N1.02 - VLT
®
is a registered Danfoss trademark
35