![Danfoss ADAP-KOOL AKD 102 Operating Instructions Manual Download Page 97](http://html1.mh-extra.com/html/danfoss/adap-kool-akd-102/adap-kool-akd-102_operating-instructions-manual_3421853097.webp)
7.2.13 16-** Data Readouts
Par
. N
o
. #
P
a
rame
ter
des
cri
pti
o
n
D
e
faul
t val
u
e
4
-set-up
C
hange
dur
ing
op
er
ation
Conve
r-
si
o
n
in
d
e
x
Typ
e
16-0*
Ge
neral
Status
16-00
Control
Word
0 N
/A
A
ll
s
e
t-
u
p
s
F
A
L
S
E
0
V
2
16-01
Refe
re
nce
[Unit]
0.000
R
e
fere
nceF
eed
ba
ckU
n
it
All
se
t-
u
p
s
FA
L
S
E
-3
In
t3
2
16-02
Refe
re
nce
[%]
0.0
%
A
ll
set
-ups
F
ALSE
-1
In
t16
16-03
Sta
tu
s
Wor
d
0 N
/A
All
se
t-
u
p
s
FA
L
S
E
0
V2
16-05
Ma
in
Act
u
al
V
a
lu
e
[%]
0.00
%
A
ll
set
-ups
F
ALSE
-2
N
2
16-09
Cu
st
o
m
Readou
t
0.00
CustomRe
adout
U
nit
All
se
t-
u
p
s
FA
L
S
E
-2
In
t3
2
16-1*
Motor
Stat
us
16-10
Po
wer
[kW]
0.00
kW
All
se
t-
u
p
s
FA
L
S
E
1
In
t3
2
16-11
Po
we
r [hp]
0.00
h
p
Al
l set
-ups
F
ALSE
-2
In
t32
16-12
Mo
to
r Vo
lt
age
0.0
V
All
se
t-
u
p
s
FA
L
S
E
-1
Ui
nt16
16-13
Freque
ncy
0.0
Hz
Al
l set
-ups
F
ALSE
-1
Uint16
16-14
Mo
to
r Curre
nt
0.00
A
All
se
t-
u
p
s
FA
L
S
E
-2
In
t3
2
16-15
Freque
ncy
[%]
0.00
%
A
ll
set
-ups
F
ALSE
-2
N
2
16-16
To
rq
u
e
[
N
m
]
0.
0
N
m
All
se
t-
u
p
s
FA
L
S
E
-1
In
t1
6
16-17
Spe
e
d
[RPM]
0 R
P
M
A
ll
s
e
t-
u
p
s
F
A
L
S
E
6
7
In
t3
2
16-18
Mo
to
r Thermal
0 %
All
se
t-
u
p
s
FA
L
S
E
0
Ui
nt
8
16-22
T
o
rque
[%]
0 %
A
ll
s
e
t-
u
p
s
F
A
L
S
E
0
In
t1
6
16-3*
Drive
S
tatus
16-30
DC
Lin
k
V
o
lt
age
0 V
A
ll
s
e
t-
u
p
s
F
A
L
S
E
0
U
in
t1
6
16-32
Br
a
k
e
E
n
er
g
y
/
s
0.000
k
W
All
se
t-
u
p
s
FA
L
S
E
0
Ui
nt32
16-33
B
rake
Energy
/2
min
0.000
k
W
Al
l set
-ups
F
ALSE
0
U
int32
16-34
Heatsi
n
k
Temp.
0 °
C
All
se
t-
u
p
s
FA
L
S
E
100
Ui
nt
8
16-35
Inverte
r Therma
l
0
%
A
ll
se
t-
u
p
s
F
A
L
S
E
0
U
in
t8
16-36
Inv.
Nom.
Curr
ent
E
xp
re
ssi
onLi
mit
All
se
t-
u
p
s
FA
L
S
E
-2
Ui
nt32
16-37
Inv.
Ma
x.
Curr
e
n
t
E
xp
re
ssi
onLi
mit
A
ll
se
t-u
p
s
F
A
L
S
E
-2
U
int32
16-38
SL
Cont
rol
le
r
S
ta
te
0 N
/A
All
se
t-
u
p
s
FA
L
S
E
0
Ui
nt
8
16-39
Control
Card
Te
mp.
0
°C
Al
l set
-ups
F
ALSE
100
Uint
8
16-40
L
o
ggi
ng
B
u
ffer
Full
[0
] N
o
All
se
t-
u
p
s
TRUE
-
Ui
nt
8
16-5*
Re
f.
&
Fe
edb.
16-50
E
xte
rnal
Refe
re
nce
0.0
N
/A
All
se
t-
u
p
s
FA
L
S
E
-1
In
t1
6
16-52
Fee
d
back
[U
nit]
0.000
Proce
ssC
trlU
nit
A
ll
set
-up
s
F
ALSE
-3
In
t32
16-53
Digi
Pot
Refe
re
nce
0.00
N/A
All
se
t-
u
p
s
FA
L
S
E
-2
In
t1
6
16-54
Fee
d
back
1
[U
nit
]
0.000
Proce
ssCtrl
U
ni
t
A
ll
se
t-u
p
s
F
A
L
S
E
-3
In
t32
16-55
Fee
d
back
2
[U
nit
]
0.000
Proce
ssC
trlU
nit
All
se
t-
u
p
s
FA
L
S
E
-3
In
t3
2
16-56
Fee
d
back
3
[U
nit
]
0.000
Proce
ssCtrl
U
ni
t
A
ll
se
t-u
p
s
F
A
L
S
E
-3
In
t32
How to Programme the Frequ...
ADAP-KOOL
®
Drive Operating Instructions
MG.11.L4.02 - ADAP-KOOL
®
Drive
97
7
7