background image

Principle

Instructions

AK-PC 651

Identification

080G0312 

1,5 m: 080G0075

3,0 m: 080G0076

MMIGRS2: 080G0294

Termination!

H-R

Termination! 

H-R

RI8RD4ML  2015-04

IP 20

-20 - 60°C

(0 - 140°F)

RH max. 90% non condensing

External display

Summary of Contents for ADAP-KOOL AK-PC 651

Page 1: ...e Instructions AK PC 651 Identification 080G0312 1 5 m 080G0075 3 0 m 080G0076 MMIGRS2 080G0294 Termination H R Termination H R RI8RD4ML 2015 04 IP 20 20 60 C 0 140 F RH max 90 non condensing External...

Page 2: ...3 supply 12 V AI Analogue inputs 4 pcs AI7 AI10 Pressure transmitters Ratiometric 10 90 of supply AKS 32R Signal 1 5 V AKS 32 Factory settings AI7 Po AI8 Pc Temperature sensor See above Supply Voltage...

Page 3: ...tage Digital Inputs 4 pcs DI1 DI4 Terminals DI1H DI1 DI common 230 V signal Connect to DI_H 24 V signal Connect to DI_ The connection may be a shut down or interruption function Select what is to be a...

Page 4: ...0 100 for the unloader The unloader is connected to DO5 or DO6 Copeland Stream 6 The signal can also be used to control one stream compressor with two unloading valve The compressor capacity is distri...

Page 5: ...entradas anal gicas 4 pcs AI7 AI10 Transmissores de press o Ratiometric 10 90 do fornecimento AKS 32R Sinal 1 5 V AKS 32 Configura es de f brica AI7 Po AI8 Pc Sensor de temperatura Como acima Tens o d...

Page 6: ...baixa tens o 4 p s DI1 DI4 Terminais DI1H DI1 DI comum Sinal de 230 V Conectar a DI_H Sinal de 24 V Conectar a DI_ A conex o pode ser um desligamento ou uma fun o de interrup o Selecione o que deve se...

Page 7: ...ompressor de fluxo com uma v lvula de descarregador A capacidade do compressor distribu da por at 50 para um rel in cio e os restantes 50 100 para o descarregador O descar regador est conectado em DO5...