1.
2.
3.
1.
2.
2.5 Installing the Bottom Cover
Use the following steps to install the bottom cover . See
.
Procedure
Adhere the bottom cover gasket to the upper surface of the bottom cover.
If mounting the frequency converter on a pedestal, install the bottom cover after the pedestal is attached.
Position the bottom cover over the opening in the base plate at the lower end of the cooling channel.
Secure the bottom cover using 6 M5x16 screws (T25) from the kit.
e30bk581.10
Illustration 5: Bottom Cover Installation
2.6 Installing the Cable Entry Plate
The cable entry plate provides cable entry and cable termination points. The plate is installed to maintain the IP21/Type 1 or IP54/
Type 12 protection rating.
To install the cable entry plate, use the following steps. See
.
Procedure
Create cable entry holes in the plate using a sheet metal punch.
Reuse the cable entry plate that was removed during base plate installation.
Position the cable access plate at the bottom of the frequency converter.
AN371942578354en-000101 / 136R0290 | 7
Danfoss A/S © 2023.09
Installation
In-back/Out-back Cooling Kit for FK09c/FB09c and FK10c/FB10c
Installation Guide