background image

  

1  

July 31, 2019 

 

 

F5S-IQ INSTALLATION MANUAL

 

 

 

 

Model F5S-IQ1 

 

 

  

  F5S-IQ2 

 

 

IMPORTANT: 

Carefully read ALL instructions and warnings before attempting to install and            

operate this equipment. 

 

Summary of Contents for F5RS-IQ Series

Page 1: ...1 July 31 2019 F5S IQ INSTALLATION MANUAL Model F5S IQ1 F5S IQ2 IMPORTANT Carefully read ALL instructions and warnings before attempting to install and operate this equipment ...

Page 2: ...FIGURATION Page 7 7 F5S IQ TOUCHPAD PROGRAMMING Page 8 8 F5S IQ VOLTAGE CALIBRATION Page 8 9 F5S IQ TEMPERATURE CALIBRATION Page 9 10 F5S IQ TOUCHPAD BACKLIGHT QUICK SETTING Page 9 11 IMAGES Page 10 REAR VIEW CONNECTORS LAYOUT Page 10 FRONT VIEW CONNECTORS LAYOUT Page 11 TOP VIEW FUSES AND LED INDICATORS Page 11 12 TOUCHPAD SETUP FILE UPLOAD ERROR CODES Page 11 13 WARRANTY PRODUCT RETURN POLICY Pa...

Page 3: ...n hardware should be used to anchor and protect wires Splices should be minimized and made in a fashion so as to protect them from corrosion to minimize the possibility of loss of conductivity over time INSTALLATION OF ALL EQUIPMENT AND WIRING SHALL NOT OBSRUCT IMPEDE OR INTER FERE WITH THE DEPLOYMENT OF VEHICLE AIR BAGS OTHERWISE IT COULD POSSIBLY RE DUCE THE EFFECTIVENESS THE AIR BAG SYSTEM CAUS...

Page 4: ...ortion 10 or less Audio Output Power 32 watts Siren Output Power 100 Watts NOTE TOTAL current draw not to exceed 60A including siren Current Outputs PLUG 1 Pin 4 OUTPUT 1 20 Amp Max fused 20A PLUG 2 Pin 2 OUTPUT 1 10 Amp Max fused 15A Pin 3 OUTPUT 2 10 Amp Max fused Pin 4 OUTPUT 3 10 Amp Max fused Pin 5 OUTPUT 4 10 Amp Max fused Pin 6 OUTPUT 5 10 Amp Max fused Pin 7 OUTPUT 6 10 Amp Max fused Pin 8...

Page 5: ...1 PIN 4 cannot be used PIN 3 OUTPUT 2 10A MAX PIN 4 OUTPUT 3 10A MAX PIN 5 OUTPUT 4 10A MAX PIN 6 OUTPUT 5 10A MAX PIN 7 OUTPUT 6 10A MAX PIN 8 OUTPUT 7 10A MAX PIN 9 OUTPUT 8 10A MAX CONNECTOR 3 PIN 1 OUTPUT 9 2A MAX PIN 2 OUTPUT 10 2A MAX PIN 3 OUTPUT 11 2A MAX PIN 4 OUTPUT 12 2A MAX PIN 5 OUTPUT 13 2A MAX PIN 6 OUTPUT 14 2A MAX PIN 7 OUTPUT 15 2A MAX PIN 8 OUTPUT 16 2A MAX PIN 9 OUTPUT 17 2A MA...

Page 6: ...ME ADJUSTMENT MICROPHONE JACK 5 LABELING INSTRUCTIONS 1 Remove the Slide Switch red knob 2 Using a Phillips screwdriver remove the 4 self tapping screws securing the back cover of the touchpad 3 Using a small flat screwdriver carefully separate the front cover from the back cover 4 Select the appropriate push button label from the enclosed label packet 5 Orient the label in the same direction as t...

Page 7: ...GER tone A fourth press it will activate again the WAIL tone This cycle continues until the user deactivates the Hands Free mode Pressing the horn ring twice in a quick succession when STBY is selected it will turn OFF the siren tone and sets the system into Hands Free ready mode Pressing the horn ring twice in a quick succession when any of the siren tones is selected it will turn OFF the siren T...

Page 8: ...ss SW9 to decrease SW10 to increase Press SW8 to save and move to next function Step 4 Enter DISPBRIGHT setup To adjust press SW9 to decrease SW10 to increase Press SW8 to save and exit programming 8 F5S IQ VOLTAGE CALIBRATION The F5S IQ system provides a continuous battery voltage reading on the touchpad s display After a setup update the display will show Voltage 0V even though the voltage input...

Page 9: ...PSENSOR 1 Adjust the temperature on the display to match the temperature measured in Step 1 Use SW9 to increase and SW10 to decrease value Step 4 Press SW8 to save If a second temperature sensor is present repeat Step 3 to calibrate TempSensor 2 If not the system will exit temperature calibration process Step 5 Press SW8 to save If the third temperature sensor is present repeat Step 3 to calibrate...

Page 10: ...10 July 31 2019 11 IMAGES IQ CONTROL BOX REAR VIEW Figure 1 Input Output Layout ...

Page 11: ...id TP 4 UNEXPECTED_RECORD TPP file unexpected record exist file content is wrong Error 4 5 LIGHTBAR_COMM TouchPad has no communication with LightBar L Comm Err 6 RELAY_COMM TouchPad has no communication with Relay Board R Box Err 7 FILE_ERR TPP file read write error Error 7 8 USB_ERR Detect USB thumb drive error Init Failed Remove Drive 9 MEMORY_ERR Read USB thumb error Memory Fault 10 FILE_NOT_FO...

Page 12: ... installation Lamps flash tubes batteries or other items considered consumables are not covered under warranty This warranty is in lieu of all other express warranties D R Electronics makes no warranties expressed or implied other than the express warranties contained herein WARRANTY PRODUCT RETURN POLICY In order to provide you with faster service product returns for repair or replacement must ha...

Reviews: