d&b audiotechnik Z5560 Manual Download Page 7

7

7

D20 Touring rack assembly US Manual 1.0

3.2.2. MAINS SUPPLY

The ML 1105 Mains power distributor is supplied with a fixed 

3-phase 30 A L21-30 mains connector socket.
When the rack is connected to the on-site mains power supply, three 

LED indicators display the presence of the on-site mains supply lines 

(phase conductor X, Y, Z).

WARNING! 

Potential risk of electric shock.

The mains power distributor is a type 1 enclosure. A missing earth 

(ground) contact may cause dangerous voltages in the housing and 

controls and may lead to electric shock.

 

Connect the unit to mains power supplies with protective earth 

only.

 

If there is any sign of obvious damage to the power cord and/

or L21-30 mains connector, do not use the unit and replace it 

before further use.

 

Please ensure the mains connector is accessible at any time to 

disconnect the unit in case of malfunction or danger.

 

Do not connect or disconnect the L21-30 mains connector under 

load or live.

Mains supply configuration

Input Voltage ............................................120/208Y VAC 3PH 60Hz
Wiring configuration ....................................................................4P5W
Max Ampacity ............................................................................... 30 A

NOTICE!
To avoid any overload of the on-site mains power supply, we 

recommend you to connect no more than one system rack to the  

respective mains power supply line.

3.2.3. AUXILIARY MAINS OUTPUT 20 A

The installed D20 amplifiers will use three of the six available 

NEMA 5-20 sockets. Three remaining sockets are intended for the 

connection of low current devices such as notebook computers, 

DS10 Audio Network Bridge, or additional Ethernet switches.

Summary of Contents for Z5560

Page 1: ...DD20 Touring rack assembly US Manual 1 0 ...

Page 2: ...ture reference When reselling this product hand over this manual to the new owner If you supply d b products please draw the attention of your customers to this manual Enclose the relevant manuals with the systems If you require additional manuals for this purpose you can order them from d b d b audiotechnik Corporation 30A Rosscraggon Road Asheville NC 28803 1 828 681 5405 F 1 828 681 5545 suppor...

Page 3: ...ed use 3 2 Power 3 2 1 AMP 1 AMP 2 AMP 3 3 2 2 MAINS SUPPLY 3 2 3 AUXILIARY MAINS OUTPUT 20 A 3 3 Signal 3 3 1 4 CH OUTPUTS NL8 4 Z5338 I O Panel 9 4 1 INPUT 4 2 INPUT LINK 4 3 REMOTE 5 Z5333 Rack link 11 6 Z4010 DS10 Audio network bridge 12 6 2 DS10 select example deployments 6 1 Use with d b Touring rack I O panel The DS10 replaces the 1RU drawer of the complete rack assembly 7 Declarations 13 7...

Page 4: ...purpose the touring rack is equipped with a mains power distribution device ML 1105 which also serves as a loudspeaker connector panel Also incorporated is an I O panel Z5338 which serves as a connector interface for both analog and digital audio signals In addition four network connectors are provided for either Ethernet or CAN Bus remote capabilities 1 2 Scope of supply Before starting up please...

Page 5: ...y make sure to provide sufficient space of 0 5 m 1 6 ft at the front and rear of the touring rack to ensure sufficient cooling airflow D20 Touring rack assemblies as well as D20 and D80 Touring racks can be stacked or positioned side by side When combining the Z5560 D20 Touring rack assembly with the Z5310 D12 Touring rack assembly or any other rack assembly that produces an opposing airflow obser...

Page 6: ...es as a loudspeaker connection panel for different connection options It is a type 1 enclosure intended for indoor use only The ML 1105 Mains power distributor must not be used for any other purpose or outside the system rack 3 2 Power 3 2 1 AMP 1 AMP 2 AMP 3 Three single phase mains power outlet 1 2 3 each fitted with a NEMA 5 20 mains socket are provided for the internal mains power supply of th...

Page 7: ... to the power cord and or L21 30 mains connector do not use the unit and replace it before further use Please ensure the mains connector is accessible at any time to disconnect the unit in case of malfunction or danger Do not connect or disconnect the L21 30 mains connector under load or live Mains supply configuration Input Voltage 120 208Y VAC 3PH 60Hz Wiring configuration 4P5W Max Ampacity 30 A...

Page 8: ...active systems to the 4 CH OUTPUTS connectors otherwise there is a risk of damaging the loudspeaker components or the amplifier Each of the 4 CH OUTPUTS connectors represents the 4 CHANNEL OUTPUT of the respective D20 amplifier Each connector carries the output signals of all four channels of the amplifier with the following pin assignment 1 Channel A pos neg 2 Channel B pos neg 3 Channel C pos ne...

Page 9: ...scription of remote control via Ethernet is given in the technical information TI 310 d b code D5310 EN which can be downloaded from the d b website at www dbaudio com 4 1 INPUT The INPUT section represents the input connectors of the first amplifier while the other two amplifiers are linked within the rack The INPUT section allows both analog and digital audio signals to be fed to the amplifier 4...

Page 10: ...INK The built in termination switch allows two settings 1 LINK In system racks at the start of and within a CAN Bus segment set the switch to LINK 2 TERMINATE On the last system rack of a CAN Bus segment set the switch to TERMINATE Note A detailed description of remote control via the d b Remote network CAN Bus is given in the technical information TI 312 d b code D5312 EN which can be downloaded ...

Page 11: ...udio signals as well as for network wiring Ethernet or CAN Bus networks Technical specifications Audio connector 2 x XLR female to 2 x XLR male with color markup Audio signal capability Analog Digital AES EBU AES 3 Network connector etherCON Network cable CAT 5E SFTP Length 2 m 6 5 ft Rack link example 4ch Digital audio and CAN Bus Rack link example 2ch Analog audio and CAN Bus ...

Page 12: ...panel in order to bridge the R1 control for the amplifiers over the Dante network Note Connect only one of the Ethernet ports on the I O panel to the DS10 Otherwise an Ethernet ring is built causing a packet storm leading to the Network no longer being accessible 4 On the rear the power cord 1 powerCON L5 15 is connected to the auxiliary NEMA 5 20 socket of the mains distributor Note When ordered ...

Page 13: ...ies ML 1105 001 is ETL listed Conforms to UL STD 508A UL STD 1640 Certified to CAN CSA STD C22 2 NO 14 7 2 Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Please dispose of this product according to the respective national regulations or contractual agreements If there are any further questions concerning the disp...

Page 14: ...www dbaudio com 09 2016 d b audiotechnik Corporation ...

Reviews: