2.2  Connections
The cabinets are fitted with a pair of NLT4 F/M connectors. All

four pins of both connectors are wired in parallel. The Y8 and Y12

loudspeakers use the pin assignments 1+/1–. Pins 2+/2– are

designated to actively driven subwoofers. Using the male

connector as the input, the female connector allows for direct

connection to a second cabinet.
The cabinets can be supplied with NL4 M or EP5 connectors as an

option.
Pin equivalents of the connector options are listed in the table

below.

NLT4 F/M

NL4 M

1+

1–

2+

2–

n.a.

EP5

1

2

3

4

5

d&b LoadMatch
Starting with the D80 amplifier platform, the LoadMatch function

enables the amplifier to electrically compensate for the properties

of the loudspeaker cable used without the need for an additional

sense wire. For applicable loudspeakers, LoadMatch is therefore

independent of the connector type used.

2.3  Operation

NOTICE!

Only operate d&b loudspeakers with a correctly configured d&b

amplifier, otherwise there is a risk of damaging the loudspeaker

components.
Applicable d&b amplifiers:

D80/D20/D12/D6/10D/30D.

Application

Setup

Cabinets per

channel

Y8

Y8 Arc/Y8 Line

2

Y12

Y12 Arc/Y12 Line

2

The applicable d&b amplifiers provide two setups ("Arc" or "Line")

for the Y8 and Y12 loudspeakers. These are available in Dual

Channel or Mix TOP/SUB mode.

Arc and Line setups
The selection of Arc or Line depends on the curvature of the array.

Both setups may be used within one array.
The Arc setup is intended for line array loudspeakers when used in

curved array sections.
The Line setup is used for long throw array sections with three or

more consecutive splay settings of 0°, 1° or 2°. Compared to the

Arc setup, the mid/high range is reduced to compensate for the

extended nearfield.

passi

ve

crossover

Connector wiring

 

d&b Y8/Y12 Manual 1.2 en

6

Summary of Contents for Y Series

Page 1: ...Y Y8 Y12 Manual 1 2 en ...

Page 2: ...ly check the d b website for the latest version of this document When reselling this product hand over this document to the new owner If you supply d b products please draw the attention of your customers to this document Enclose the relevant documents with the systems If you require additional documents for this purpose you can order them from d b d b audiotechnik GmbH Eugen Adolff Straße 134 D 7...

Page 3: ... 1 Product description 5 2 2 Connections 6 2 3 Operation 6 2 3 1 Controller settings 7 2 4 Dispersion characteristics 8 2 5 Technical specifications 9 3 Manufacturer s declarations 10 3 1 EU conformity of loudspeakers CE symbol 10 3 1 1 WEEE Declaration Disposal 10 Contents d b Y8 Y12 Manual 1 2 en 3 ...

Page 4: ...ries as detailed in our specific Mounting instructions or in our Flying system and Rigging manuals Ensure that all additional hardware fixings and fasteners used for installation or mobile deployment are of an appropriate size and load safety factor Pay attention to the manufacturers instructions and to the relevant safety guidelines Regularly check the loudspeaker housings and accessories for vis...

Page 5: ...xtends from 54 Hz to above 19 kHz The cabinets are constructed from marine plywood and have an impact and weather protected PCP Polyurea Cabinet Protection finish The fronts of the cabinets are protected by a rigid metal grill backed by an acoustically transparent foam Each side panel incorporates a handle while two additional recessed grips are provided at the rear Y Series rigging components and...

Page 6: ...atch is therefore independent of the connector type used 2 3 Operation NOTICE Only operate d b loudspeakers with a correctly configured d b amplifier otherwise there is a risk of damaging the loudspeaker components Applicable d b amplifiers D80 D20 D12 D6 10D 30D Application Setup Cabinets per channel Y8 Y8 Arc Y8 Line 2 Y12 Y12 Arc Y12 Line 2 The applicable d b amplifiers provide two setups Arc o...

Page 7: ... system is used in full range mode without subwoofers Note Make sure that all cabinets within the line array are operated with the same CPL setting HFC function Selecting the HFC High Frequency Compensation function compensates for the loss of high frequency energy due to air absorption when loudspeakers are used to cover far field listening positions The HFC function has two settings HFC1 and HFC...

Page 8: ...r frequency plotted using lines of equal sound pressure isobars at 6 dB and 12 dB The nominal dispersion is maintained above 600 Hz while a useful horizontal dispersion control is achieved down to 500 Hz Isobar diagram Y12 horizontal Isobar diagram Y8 horizontal d b Y8 Y12 Manual 1 2 en 8 ...

Page 9: ... ohms Power handling capacity RMS peak 10 ms 400 1600 W Nominal dispersion angle horizontal Y8 80 Nominal dispersion angle horizontal Y12 120 Splay angle setting 0 14 1 increment Components 2 x 8 driver 1 x 1 4 exit compression driver Passive crossover network Connections 2 x NLT4 F M optional 2 x NL4 M or EP5 Pin assignment NLT4 F M and NL4 M 1 1 EP5 1 2 Weight 20 kg 44 lb Y8 Y12 cabinet dimensio...

Page 10: ...ons of the respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com 3 1 1 WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Please dispose of this product according to...

Page 11: ......

Page 12: ...D2712 EN 01 10 2016 d b audiotechnik GmbH www dbaudio com ...