![d&b audiotechnik 5D Startup Manual Download Page 17](http://html.mh-extra.com/html/dandb-audiotechnik/5d/5d_startup-manual_494362017.webp)
Startup
5.2.4 OUTPUTS
WARNING!
Potential risk of electric shock or fire.
Risk of electric shock
The amplifier output pins can carry dangerous voltages.
▪ Only use isolated loudspeaker cables with correctly fitted
connectors.
▪ Never connect an amplifier output pin to any other input or
output connector pin or protective earth (ground).
▪
Bridge mode is not applicable.
Risk of fire
To avoid any heating of the output connector terminal (glowing
contact), the wires need to be properly fitted to the output
connector terminal.
▪ Only use the enclosed Euroblock 5.08 mm connector terminals.
▪ Observe the maximum cross-section of 2.5 mm
2
(AWG 13).
▪ Ensure all contact screws are properly tightened.
Rated
torque settings (max): 0.5 N
×
m.
▪ Screw driver size Phillips PH1 (0.6 x 3.5 mm).
The amplifier is equipped with two Euroblock connector sockets
(female), one for each pair of amplifier output channels (A/B,
C/D).
All pins of both output connectors are hardwired and permanently
driven using the following pin assignment.
OUTPUTS A (B, C, D)
+ = Amp A (B, C, D) pos.
— = Amp A (B, C, D) neg.
Note: A detailed description of the applicable output modes
and how to configure the appropriate output mode is given in
the 5D Reference manual which can be downloaded from the
related product page at
For further information regarding the applicable output modes
for each loudspeaker system, please refer to the relevant
loudspeaker manual.
d&b 5D Start-up manual 1.1 en
- preliminary -
17