background image

 

                         

OWNER’S USE AND CARE GUIDE
GUIDE D’UTILISATION ET D'ENTRETIEN

02'(/‡02'Ê/(

DANBY PRODUCTS LIMITED, ONTARIO, CANADA N1H 6Z9

DANBY PRODUCTS INC., FINDLAY, OHIO, USA 45840

AIR CONDITIONER
CLIMATISEUR

DAC080ECB2GDB / DAC080EUB2GDB 
DAC100ECB2GDB / DAC100EUB2GDB
DAC120ECB2GDB / DAC120EUB2GDB

2014.12.05

Summary of Contents for DAC080ECB2GDB

Page 1: ...ISATION ET D ENTRETIEN 02 02 DANBY PRODUCTS LIMITED ONTARIO CANADA N1H 6Z9 DANBY PRODUCTS INC FINDLAY OHIO USA 45840 AIR CONDITIONER CLIMATISEUR DAC080ECB2GDB DAC080EUB2GDB DAC100ECB2GDB DAC100EUB2GDB...

Page 2: ...ns que votre produit Danby r pond tous vos besoins Votre satisfaction est notre priorit Veuillez nous contacter au num ro gratuit de service apr s vente si vous avez des questions quelconques propos d...

Page 3: ...nder any circumstances be cut or removed Never use the cord the plug or the appliance when they show any sign of damage Do not use your appliance with an extension cord unless it has been checked and...

Page 4: ...antes Caract ristiques Consignes d installation Consignes d utilisation Soins et entretien D pannage Garantie CONTENTS Model Mod le CAUTION Read and follow all safety rules and operating instructions...

Page 5: ...must provide the original receipt NOTE THIS UNIT IS NOT DESIGNED FOR THROUGH THE WALL INSTALLATION Model No Serial No Date Purchased NEED HELP Before you call for service here are a few things you can...

Page 6: ...into a matching wall outlet If you are not sure whether your wall outlet is properly grounded please consult a qualified electrician 5 The wall outlet must match the 3 prong plug on the service cord s...

Page 7: ...art your air conditioner before the outdoor air becomes hot to avoid an initial period of discomfort while the unit is cooling the room Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCT...

Page 8: ...nstalling or servicing NOTE Your Room Air Conditioner is designed for easy installation in a single or double hung window This unit is NOTdesigned for vertical slider type windows and or through the w...

Page 9: ...ects within the room should be prevented from blocking the air flow 5 Be certain that the proper electrical outlet is within reach of the installation Use only a single outlet circuit rated at 15 amps...

Page 10: ...haped mounting bracket on top positioned in front of the upper window sash The bottom of the cabinet should be positioned on the recessed portion of the window frame Pull the window down until it rest...

Page 11: ...ately 3 4 in 19 mm to 1 in 2 5 cm for approximately 1 in 2 5 cm to 1 3 8 in 3 5 cm for INSTALLATION INSTRUCTIONS KEY PAD FEATURES MODE Auto Auto 68 Temp Timer Control Check Filter Mode Selector Energy...

Page 12: ...ned for 6 hours before returning to the originally selected temperature This ends the Sleep mode and the unit will continue to operate as originally programmed The Sleep mode program can be cancelled...

Page 13: ...ler Do not expose the remote controller to direct sunlight or heat If the infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not function properly Use cu...

Page 14: ...ess this button to activate the energy saving mode Press it again to stop the function This function is available in COOL DRY and AUTO modes only Auto cool and Auto fan modes MODE BUTTON Each time you...

Page 15: ...selected manu ally Model Mod le R15B COOLING FAN OPERATION Ensure the unit is plugged in and power is available 1 Press the ON OFF button to start the air conditioner 2 Press the MODE button to selec...

Page 16: ...TIMER OPERATION Pressing the TIMER button can set the Auto start and Auto stop time of the unit NOTE To set Auto start time the unit must be in the OFF position To set Auto stop time the unit must be...

Page 17: ...ed wait for about 10 seconds until the setting temperature reappears in the display window of the air conditioner This indicates that the program has been set NOTE To cancel the TIMER setting push the...

Page 18: ...ce pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residen tial installation This equipment generates uses and can rad...

Page 19: ...2 Wash the filter in lukewarm water below 40 C 104 F To get best results wash with soapy water or a neutral clean ing agent 3 Rinse the filter with clean water and dry thoroughly before re installing...

Page 20: ...5 minutes before at tempting to restart Noisy unit Loose parts Tighten loose parts Inadequate support Provide additional support to unit Odors Formation of mold mildew or algae on wet surfaces Clean u...

Page 21: ...authorized Danby Service Depot as service must only be performed by a technician qualified and certified for warranty service by Danby Transpor tation charges to and from the service location are not...

Page 22: ...ents g n raux Pour b n ficier d une op ration de maintenance ou de d pannage le re u original sera exig REMARQUE CET APPAREIL N A PAS T CON U POUR UNE INSTALLATION TRAVERS UNE PAROI MURALE Num ro de m...

Page 23: ...i vous n tes pas certain que votre prise de courant murale est mise la terre ad quatement veuillez consulter un lectricien qualifi 5 La prise murale doit correspondre la fiche 3 broches sur le cordon...

Page 24: ...r la p n tration et le r chauffement de la pi ce par les rayons directs du soleil mais ne pas permettre la restriction de la circulation d air autour de l unit par les draperies ou les rideaux 4 Activ...

Page 25: ...ation ou le service Comme le compresseur se trouve du c t des commandes de l unit c t gauche ce c t est plus lourd et plus difficile manipuler Un soutien inappropri du c t des commandes de l appareil...

Page 26: ...rideaux ou d autres objets l int rieur de la pi ce puissent bloquer le flux d air 5 Assurez vous que la prise lectrique appropri e se trouve la port e de l installation N utilisez qu un circuit prise...

Page 27: ...L en haut positionn e l avant du cadre sup rieur de la fen tre Le bas du caisson doit tre positionn dans le bas du cadre de la fen tre Tirez la fen tre vers le bas jusqu ce qu elle repose juste derri...

Page 28: ...H environ 1 1 3 8 po 2 5 cm 3 5 cm pour CONSIGNES D UTILISATION FONCTIONNEMENT MODE Auto Auto 68 R glage de la temp rature et minuterie V rifiez le filtre S lecteur de modes conom iseur d nergie Affi...

Page 29: ...ra maintenue pendant 6 heures avant le retour la temp rature initialement s lectionn e Cela met fin au mode Sommeil et l appareil continuera de fonction ner conform ment sa programmation initiale Le p...

Page 30: ...ommande la chaleur ou la lumi re directe du soleil Si le r cepteur du signal infrarouge qui se trouve sur l unit int rieure est expos la lumi re directe du soleil il est possible que le climatiseur ne...

Page 31: ...seur d nergie Appuyez le encore une fois pour d sactiver la fonction Cette fonction est disponible lorsque l appareil est en modes Frais Sec et Auto Auto Frais et Auto Ventilateur modes seulement BOUT...

Page 32: ...NTILATEUR Assurez vous que l appareil est branch et sous tension 1 Appuyez sur le bouton MARCHE ARR T pour mettre le climatiseur en marche 2 Appuyez sur le bouton MODE pour choisir le mode Refroidisse...

Page 33: ...e bouton MINUTERIE pour r gler l heure de mise en marche automatique et d arr t automatique de l appareil REMARQUE Pour r gler l heure de mise en marche automatique l appareil doit tre sur la position...

Page 34: ...raisse sur l afficheur du climatiseur Cela indique que le programme est r gl REMARQUE Pour annuler le r glage du minuteur appuyez sur le bouton ou jusqu ce que 0 heure apparaisse sur l afficheur ACL d...

Page 35: ...s num riques de classe B en vertu de l alin a 15 du r glement de la FCC Ces limites sont destin es assurer une protection raisonnable contre les interf rences nuisibles dans un environnement r sidenti...

Page 36: ...le filtre dans de l eau ti de de moins de 40 C 104 F Pour obtenir de meilleurs r sultants lavez avec une eau savonneuse ou un agent neutre de nettoyage 3 Rincez le filtre avec de l eau propre et s ch...

Page 37: ...esserr es Support inad quat Fournissez un support suppl mentaire l appa reil Odeurs Formation de moisissure ou d algues sur les surfaces mouill es Nettoyez fond l appareil Mettez une tablette anti alg...

Page 38: ...cien qualifi et certifi pour effectuer un entretien couvert par la garantie de Danby Les frais de transport entre votre domicile et le lieu de l entretien ne sont pas couverts par la pr sente garantie...

Page 39: ...________________ __________________________________________________________________________________________ __________________________________________________________________________________________ _...

Page 40: ...onibles votre centre de service r gional autoris Pour obtenir le service et ou la localit de votre centre de service r gional signalez le NUM RO D APPEL SANS FRAIS Ayez les renseignements suivants la...

Reviews: