Section 4: Specifications
Danaher Motion
14
SS2000 D3 AND D6
4.5 - 6.0 VDC, 16 mA PER SIGNAL
OPTO
PULSE
DRIVE
CONTROL SIGNAL
TTL
7406
OPTO
PULSE
DRIVE
560 ohms
1/4 watt
12 VDC, 16 mA PER SIGNAL
CONTROL SIGNAL
CONTROL LOGIC COMMON
4.5 - 6.0 VDC, 16 mA PER SIGNAL
OPTO
PULSE
DRIVE
CONTROL SIGNAL
CONTROL LOGIC COMMON
Figure 4.2 Suggested Methods For Control Interface
4.8 I
NDICATOR
L
IGHTS
"POWER" LED, Red
Lights when the drive logic power supply is present, indicating the drive is
energized.
"OVERCURRENT" LED, Red
Lights to indicate over-current condition. This condition is a result of motor wiring
errors or a ground fault. Recovery from this condition requires removing AC power,
correcting the problem, then re-energizing AC power.
"OVER TEMP" LED, Red
Lights to indicate the air temperature inside the drive has exceeded a safe level for
reliable operation. Recovery from this condition requires removing and reapplying
the AC power.
4.9 T
EST
A pushbutton Test switch is located on the front panel. To operate the Test function,
disconnect the translator input connector and actuate the switch. If the drive and motor
are wired correctly, the motor rotates clockwise at about 1/2 revolution per second.