Danaher Motion Superior Electric
Section 3: Installation Guidelines
SS2000 D3 AND D6
7
3.3.1 Motor Connections
All motor connections are made via the 5-pin connector. Pin assignments for
this connector are:
Motor Connection
Pin Assignment
Leads
Terminals
1
M1 (Phase A) Red
#1
2
M3 (Phase A) White/Red
#3
3
M4 (Phase B) Black
#4
4
M5 (Phase B) White/Blk
#5
5
Shield
Shield
-
Motor phase A is M1 and M3 and motor phase B is M4 and M5. The
motor frame must be grounded.
Cabling from the drive to the motor should be done with a shielded, twisted pair
cable. As a guideline, the wires for each motor phase should be twisted about six
times per foot.
Danaher Motion offers the following motor cable configurations. These cables
have unterminated leads on both ends.
Length
Part Number
10 ft (3 m)
216022-031
25 ft (7.6 m)
216022-032
50 ft (15.2 m) 216022-033
75 ft (22.8 m) 216022-034