AC SuperDrive specifications
26.04.2005
8.11.2 D
IMENSIONS
AC SuperDrive with fins.
shows dimensions for AC SuperDrive model 10 to
25 and drilling pattern for the flat heatsink versions and surface roughness and surface flatness
requirements for the flat heatsink versions. (Dimensions in mm).
AC SuperDrive Model
Flat version
Y1
Y2
Y3
Y4
ACSxx 10
165
120
-
9
ACSxx 15
233.6
150
-
41.8
ACSxx 20
302.2
215
107.5
43.6
ACSxx 25
370.8
250
125
60.4
Finned version
Y1
X1
X2
X3
ACSxx 10
165
25.5
-
114
ACSxx 15
233.6
25.5
-
182.6
ACSxx 20
302.2
25.5
125.6
251.2
ACSxx 25
370.8
25.5
159.9
319.8
8.11.3 S
URFACE REQUIREMENTS
Model
Tolerance
Rougness
ACSxx 10
0.1/270x165 mm
Ra 1.6
ACSxx 15
0.1/270x233 mm
Ra 1.6
ACSxx 20
0.1/270x302 mm
Ra 1.6
ACSxx 25
0.1/270x370 mm
Ra 1.6
Table 29 Rougness and flatness requirements for flat AC SuperDrive.
Item No.
89Y05120A
User's Guide 1.0