Wiring the Drive
05/2008
Danaher Motion
42
S200-VTS Product Manual
6.4
J1 – DC Input Drive Power
The S200 DC input drives should be powered from power supplies with reinforced isolation.
On DC input drives, J1 is a 3 pin pluggable connector.
1
3
(J1 Connector view from
front of drive).
Pin Description
J1-1 +CTRL
J1-2 BUS/CTRL
GND
J1-3 +BUS
CAUTION
To avoid damage to the connector and drive, NEVER plug or unplug J1 with power
applied.
Mating Connector Information
Screw Terminal Connector
12 – 24 AWG Wire Range, Phoenix MSTB2,5/3-STF-5,08-BK
OR
Spring Cage Clamp Connector
12 – 24 AWG Wire Range, Phoenix FKC 2,5/3-SFT-5,08-BK
OR
Crimp Connector
Crimp Shell
14-20 AWG Wire Range, Phoenix MSTBC 2,5/3-STZF-5,08-BK
Crimp Contact
14-16 AWG Wire Range, Phoenix MSTBC-MT 1,5-2,5
Crimp Contact
18-20 AWG Wire Range, Phoenix MSTBC-MT 0,5-1,0
Refer to www.phoenixcon.com.
J1-1
+CTRL
Control power input.
The DC drive a10 to +90 VDC on this
input referenced to J1-2. An isolated regulated or isolated unregulated
power supply can be used. This input can be connected to +Bus input
(J1-3) and powered by the same supply as +Bus. The control power
supply should be rated for 20 watts. While the power drain typically is 2
W to 8 W, a 20 W supply ensures reliable starting of the drive.
J1-2
BUS/CTRL GND
Power return for the control and BUS power supplies.
The
BUS/CTRL GND is connected to I/O RTN internally in the drive.
J1-3
+BUS
Main power input to the drive.
The DC drive a20 to +90 VDC
on this input referenced to J1-2. An isolated regulated or isolated
unregulated power supply can be used. The +Bus power drain with +Bus
voltage at 75 VDC is in the range shown below. It varies according to the
application and motor.
S20330 (3 Amp)
S20630 (6 AMP)
+Bus (Continuous Power)
250 watt
500 watt
+Bus (Peak Power)
750 watt
1,500 watt
NOTE
Refer to the DC Power Supply Requirements section for detailed requirements
selecting a compatible power supply.
PE
Screw
Connection
Protective Earth connection point.
This chassis ground point
must be
connected to Protective Earth ground.
The connection at the Protective
Earth ground end
must be hard wired
(do not use a pluggable
connection).
A ground fault detector (RCD) cannot be depended on for safety.