Danaher
Motion 05/2008 Accessories
S200-CNS Product Manual
23
5.2.2 Position Node Connector Kits
CK-S200-CNDN connector kit includes
command signal connector, J12, and the
encoder connector, J13 for the S200
Position Node auxiliary functions. Solder
cup connectors.
Applicable Drive Models:
All models with DNS or CNS suffix.
CK-S200-CNDN-TB connector kit
includes command signal connector,
J12, and the encoder connector, J13 for
the S200 Position Node auxiliary
functions. For applications desiring screw
terminal (cage clamp) over soldered
connections
Applicable Drive Models:
All models with DNS or CNS suffix.
5.3 R
EGEN
R
ESISTOR
Danaher Motion offers the ERH-26 fully
enclosed, thermally protected regen
resistor rated at 26 ohms, 150 watts. The
resistor has connection leads and an
integrated thermal switch with fast-on
type connectors. The thermal switch can
be wired into the user’s safety circuit.
The ERH-26 is a UL Recognized
component.