Menu B – Part 1 : Operation related parameters (continued …)
Display
Description
Motor reversing
0=NO , 1=YES
If you want to lock any reversing of the rotating direction of the
motor you can do it here. Enter:
0
Reversing forbidden
1
Reversing according assignment either from K
EY
P
AD
or
T
ERMINAL
B
LOC
X2
Motor reversing
0=PC560 1=T.Bl.?
Motor reversing means changing the direction of the rotation.
This function can be allocated to the K
EY
P
AD
or to the T
ERMINAL
B
LOC
. Enter:
•
0
for
K
EY
P
AD
•
1
for
T
ERMINAL
B
LOC
.
The reversing function is now allocated
to terminal 31 and 32 of the terminal bloc X2. Closing this
contact will reverse the direction of the rotation.
For safety reason the factory setting is 1 to avoid K
EY
P
AD
reversing by mistake, pushing key E instead of F after 2ndF.
Filter freq. ctrl
(1 a 10) =
Input here a filter value for the analog speed reference input.
This factor need to smooth speed variations due to signal noise.
Value
1
to
10
Freq.ctrl 0=-10/+10V
1= 0 to 10V ?
Define here if your analog speed input reference is unipolar or
bipolar. Enter :
•
0
for bipolar -10V … +10V
•
1
for unipolar 0 … 10 V
Mains voltage
Ur (V) =
Enter here the nominal value in V, of the voltage of your power
supply. This value is used to detect a mains anomaly.
Input value between 200 and 480 V. All mains voltages between
170 VAC and 530 VAC are considered being inside of the
tolerances.
Partition selection
0=PC560 1=T.Bl.?
At this step you decide the way you want to select the active
partition using either the
K
EY
P
AD
or the
T
ERMINAL
B
LOC
X2
•
Enter
0
for K
EY
P
AD
control. At the next step, you will have to
enter the partition No you want to be active.
The
first partition is No “1”.
•
Enter
1
for
T
ERMINAL
B
LOC
X2
. The selection of the active
partition will be made using the terminals 34,35, 36, 37 and 38 of
the T
ERMINAL
B
LOC
X2.
Stop by default ?
0=Coast , 1=Stop.
For all non-destructive failure where the STOP can be
monitored, like
Converter temperature, External Interlocks,
….
We can choice between 2 ways of stopping the motor:
0
Coast to rest
1
Braking down using the deceleration’s ramp
Delay time
(s)=
For all non-destructive failure where the turn off can be delayed,
like
Converter temperature, External Interlocks, Motor
temperature, …
a delay time of 0 to 5 s can be input here.
This function is to allow the CNC to monitor the machine motion
before the converter trips.
Catch spinning mot.
0=NO , 1=YES ?
When this function is activated, it is possible to catch a spinning
motor and to accelerate it back to the set speed. Enter:
•
0
to lock this function
•
1
to activate it
PASSWORD:
To be able to read and / or modify the content of the available 32
partition you have to enter here the correct access password,
which is 616.
Page 30 / 48
User Manual K4000
S476-gb-0348