The programmable analog output SAN1 and SAN2
X2
42
41
AGND
SAN1
The output is 0 ... 10 V
Maximal load 10 mA
The load must be
≥
4.7 k
Ω
respectively
≤
10 k
Ω
Use one of the 0 V (electronic ground) on the terminal bloc X2 for the
return.
44
43
AGND
SAN2
SAN1
connects to terminals X2/41 and the ground X2/42
SAN2
connects to terminals X2/43 and the ground X2/44
Catch a spinning motor
50 +25VDC
45 CSM+
44 AGND
46 CSM-
When this function is activated, it is possible to catch a spinning motor
and to accelerate it back to the set speed.
The access key
The access to the programming menus can be locked using the
terminal X2/47. The access is only possible when the connection to
ground is closed. The menus to lock, i.e.
B and C or B,C,D,E,F and J
are selected in the beginning of the menu B.
X2
47
48
KEY
AGND
The RESET
In case of failure, the drive can be reset by ap25 VDC to the
terminal X2/49. A RESET is only possible when the intermediate DC
bus voltage is < 40 VDC, if higher, just wait before to redo RESET.
X2
49
50
RST
+25V
Connecting a NTC temperature sensor
X2
71
72
A
NTC +
GND
Instead of a PTC, the motor can be fit with a true temperature sensor. In
this case the connection of the sensor will be made between terminals X/71
and X/72.
S476-gb-0348
User Manual K4000
Page 23 / 48