![Danaher Motion 601...620 Product Manual Download Page 19](http://html1.mh-extra.com/html/danaher-motion/601-620/601-620_product-manual_3367905019.webp)
6.2.1
Recommended torque
Connector
Recommended torque
X3, X4
0.5 to 0.6 Nm (4.43 to 5.31 in lb)
X0A, X0B, X7, X8, X9
0.5 to 0.6 Nm (4.43 to 5.31 in lb)
Ground bolt
3.5 Nm (31 in lb)
6.2.2
Fusing
Internal Fusing
Circuit
internal fuse
Auxiliary supply 24V
3.15 AT (FRx-3)
Regen resistor
electronic
External fusing
Fusible cutouts or similar
(Fuse UL time delay)
SERVOSTAR
601/ 603
SERVOSTAR
606/ 610
SERVOSTAR
614/ 620
AC supply
F
N1/2/3
6 AT (FRx-6)
10 AT (FRx-10)
20 AT (FRx-25)
24V supply
F
H1/2/3
max. 12 AF (max. FRx-12)
Regen resistor
F
B1/2
6 AT (FRS-6)
10 AT (FRS-10)
10 AT (FR10-10)
(
x = S or S-R for 480V applications
x = N or N-R for 230V applications
)
6.2.3
Ambient conditions, ventilation, mounting position
Storage, hints
ð
Transport, hints
ð
Supply voltage tolerances
Input power
Aux. power supply
min 3x 230V
-10%
AC / max 3x 480V
+10%
, 50 Hz
min 3x 208V
-10%
AC / max 3x 480V
+10%
, 60 Hz
24 VDC (-0% +15%), check voltage drop
Ambient temperature in operation
0 to +45°C (32 to 113°F) at rated data
+45 to +55°C (113 to 131°F) with power derating
2.5% / K
Humidity in operation
rel. humidity 85%, no condensation
Site altitude
up to 1000m a.m.s.l. without restriction
1000 — 2500m a.m.s.l. with power derating
1.5%/100m
Pollution level
Pollution level 2 to EN60204/EN50178
Vibrations
Class 3111 according to IEC 721-3-3
Noise emission
max. 45 dB(A)
Enclosure protection
IP 20
Mounting position
generally vertical.
ð
Ventilation
forced convection by built-in fan
Make sure that there is sufficient forced ventilation within the switchgear cabinet.
SERVOSTAR
®
601...620 Product Manual
19
Danaher Motion
07/2007
Technical description