554
Troubleshooting
F0136 - Cabin heating system fault
Error Description
Possible Causes
Possible Solutions
The heater pump has reported a
low speed condition.
1) LV distribution system fault.
2) Blown 12V fuse F15.
3) Loss of continuity due to
defective LV connector or
harness.
4) Wrong fluid used in heating
circuit.
5) Air lock in heating circuit.
6) Heater pump internal failure.
1) Troubleshoot specific error.
2) Replace 12V fuse F15.
3) Replace LV connector or
harness per Service Manual.
4) Flush and refill heating circuit
with correct fluid.
5) Resolve air lock in heating
circuit.
6) Replace heater pump.
Connector C74
Connector C651.B
Circuit73
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...