363
Troubleshooting
F0002 (Fault Reason 0x04faff)
Error Description
Possible Causes
Possible Solutions
iAPU has detected an internal
pressure sensor failure.
1) Air leak from port 41 on iAPU.
2) iAPU internal failure.
1) Correctly plug port 41 on
iAPU.
2) Replace iAPU.
HMI displays or logs
Fault code F0002 and
Air Brake DTC 0x04faff
Defective iAPU.
Replace iAPU.
Is iAPU pneumatic port 41
plugged off?
No
No
Install new port plug into port 41
according to Bendix installation
manual.