330
Troubleshooting
F0000 (Fault Reason 0x0afae0, 0x0afaf0)
Error Description
Possible Causes
Possible Solutions
iAPU has reported that the air
dryer cartridge is due for
replacement.
1) Air dryer cartridge in need of
replacement.
2) iAPU internal failure.
1) Replace air dryer cartridge.
2) Contact Dana.
HMI displays or logs
Fault code F0000 and
Air Brake DTC 0x0afaf0/0x0afae0
Turn ignition OFF.
Replace the cartridge as per the
Bendix maintenance manual
instructions.
Is the error
message raised again
shortly after replacing the
cartridge?
Yes
No
Complete
Contact Dana for further
investigation.
Reset the fault using the Bendix
service tool as per the Bendix
service manual. Confirm reset
using Bendix tool before going
forward.
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...