Troubleshooting
HMI displays or logs
Fault code F0100 and
Traction inverter fault reason 3
Disconnect connector C3 from
the traction inverter.
Yes
Is there any connector
integrity issue?
No
Reconnect connector C3 to
the traction inverter.
Turn ignition ON.
Yes
No
Complete.
Defective connector.
Replace the connector as described in the
“Wire Harness Connector Identification,
Location, and Service Chart” in the
Service Manual.
Defective traction inverter.
Replace traction inverter.
WARNING:
Electrical hazard.
Follow Safety Warnings and High
Voltage Shutdown Procedures
defined in the Service Manual
and Diagnostic Guide.
Is the error
message still
appearing on the
HMI?
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...