297
Troubleshooting
F0097, F0098 (Fault Reason 11)
Error Description
Possible Causes
Possible Solutions
Traction inverter has limited
regenerative braking (F0097) or
traction (F0098) due to overcurrent
in the high voltage batteries.
1) Adverse driving conditions.
2) Traction inverter software or
calibration error.
1) Park vehicle outdoors out of
the sun and allow it to cool
down for 2 hours.
2) Update traction inverter
software and calibration.
Propulsion System faults may also be
investigated and resolved using the ODIN
tool and the TM4 SUMO Powertrain
Troubleshooting Guide.