168
Troubleshooting
F0005, F0006, F0007 (Charge end reason 3)
Error Description
Possible Causes
Possible Solutions
VCU has reported that BMS ended
charging normally.
1) Charging completed
successfully (no error).
2) ESS fault.
3) Incompatible or defective
EVSE.
1) No action needed; this is the
intended vehicle function.
2) Troubleshoot specific error.
3) Restart charge with compatible
EVSE.
This message is not displayed to the driver but may
still appear in the HMI fault log. If charge controller
Charge end reason 3 appears without any other
errors and the SOC is at 100% then the charging
system is operating correctly, and no troubleshooting
is needed.
If error F0154 or F0155 is raised, the SOC
measurement may not be accurate. In this case, the
technician should troubleshoot error F0154 or
F0155.
Note:
When requested to connect the
vehicle to an EVSE, either a level 2 or level
3 EVSE can be used.
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...