106
Troubleshooting
HMI displays or logs
Fault code F0026 and
BMS fault reason 48
Disconnect connectors C718, C719,
C716 and C717 from the S-Box.
Refer to connector investigation
Was a defect found in the
high voltage connectors?
No
Yes
Contact Dana for further
investigation.
Defective harness.
Replace harness.
WARNING:
Electrical hazard.
Follow Safety Warnings and High
Voltage Shutdown Procedures
defined in the Service Manual
and Diagnostic Guide.