104
Troubleshooting
Continued from previous page
Is there any evidence of a
continuity loss?
No
Yes
Defective MSD.
Replace MSD.
Inform DANA before restarting the truck.
Disconnect connectors C718, C719,
C716 and C717 from the S-Box.
Refer to connector investigation
Was a defect found in the
high voltage connectors?
No
Yes
Contact Dana for further
investigation.
Defective harness.
Replace harness.