background image

USER MANUAL

COLUMN

MODEL: 3192/3193/3194 (ADAPTER) 
MODEL: 3196/3197/3198 (BATTERY)

Summary of Contents for 3192

Page 1: ...USER MANUAL COLUMN MODEL 3192 3193 3194 ADAPTER MODEL 3196 3197 3198 BATTERY ...

Page 2: ...uct falls within the scope of the WEEE directive on recycling and recovery of waste electrical and electronic equipment This product should not be disposed of with general household waste This product must be reused if possible Contact your local authority for further details This product may also be returned to the manufacturer retailer for proper treatment recovery and recycling Dimensions and t...

Page 3: ... centre before tightening the nut Do not use any tools 3 Pull tube and wire through the rubber gasket nylon bushing and clamping nut 1 Use the special key supplied to open the door 2 Pull wire plastic tube and faucet coupling through the hole in the top plate Rubber gasket Nylon bushing Clamping nut WARNING Turn off the power to the unit before servicing or cleaning Never make alterations to the p...

Page 4: ...at the bottom of COLUMN 9 2A Push cable further upward and through the rack BATTERY MODEL 3196 3198 ADAPTER MODEL 3192 3194 ADAPTER MODEL 3192 3194 BATTERY MODEL 3196 3198 INSTALLATION 5 Attach the transparent plastic hose to the pump nozzle piece 6 Pay attention to power plug orientation pin 7 Connect the plugs on the wires between faucet and control box 8 Insert drip tray in the support rails le...

Page 5: ... box 12 Place the 5 litre bottle on the rack Insert the tube through the hole in the lid and into the bottle 11 Take off 5 litre bottle screw lid We recommend you drill a Ø7 hole for the hose Or remove the lid completely Ø7 mm REPLACEMENT OF BATTERIES AND PUMP 14 Open the battery pack with a screwdriver PH2 15 Replace 4 D batteries in the battery pack 16 Replacement of pump unit Remove tube from p...

Page 6: ...e or total block total blockage in ture Ensure the unit is placed on a firm and stable base IMPORTANT PRODUCT APPLICATION Place hands approx 2 10 cm under the sensor to activate the dispenser The dispenser will release 1 1 2 ml disinfectant gel Move hands away after disinfectant release Stops automatically when hands are moved away LIGHT INDICATOR ADAPTER Standby Red light Active Green light Obstr...

Page 7: ...TION No disinfectant is delivered Low supply Refill the disinfectant bottle Sensor window is dirty Clean the sensor window Obstruction in front of the sensor window Remove the obstruction Damaged sensor Contact DAN DRYER for advice Tube disconnected from pump If the end of the tube is damaged please remove the damaged part The undamaged tube is to be mounted on the nozzle exit of the pump Sensor c...

Page 8: ... LED print and sensor 5 Rubber gasket top 6 Rubber gasket bottom 7 Nylon bushing 8 Clamping nut 9 Tube nozzle connecting part 10 Nozzle for disinfectant 11 Tube 700mm 12 Control box DC 13 Pump for disinfectant 14 AC DC adapter 15 External battery box 16 Lock complete 17 Housing 18 Front cover 19 Mounting base 20 Top plate 21 Drip tray 22 Collar band PARTS LIST 14 15 ...

Page 9: ...DAN DRYER A S Alsikevej 8 DK 8920 Randers NV Tel 45 8641 5711 Email info dandryer dk dandryer com ...