background image

DamoaTech Soil 

Monitoring Sensor

Written and Designed by Damoatech

Install manual V.1

Summary of Contents for DT-SMS01B

Page 1: ...DamoaTech Soil Monitoring Sensor Written and Designed by Damoatech Install manual V 1 ...

Page 2: ...ter Reboot Sensor Erase Network 1 1 1 1 FarmCLO_ Device_ID Sensor Settings Page STA mode 192 168 20 1 HTTP POST Network settings Page AP mode Static IP 20 0 1 20 Sensor Settings Page IP Address Output Dynamic IP 192 168 20 X Installation overview ...

Page 3: ... server Sensor has no network information at all Full name FarmCLO_ MAC Address Sensor s unique ID MAC Address Configure WiFi Scan the AP connected by Sensor to connect the selection Configure WiFi No Scan Connect by typing SSID PW directly without Scan Erase Initialize network settings used when you want to reset network settings 3 Automatically open webpages 1 WiFi access 2 Connect to 10 0 1 10 ...

Page 4: ...Initial settings Page 2 3 Save button press Sensor reboot 1 Select the SSID you want to connect 2 Password input ...

Page 5: ...Initial settings Page 3 AP FarmCLO_8caab5812120 Search for ap to connect directly No passwd Connect to 20 0 1 20 from a web browser Check the individual IPs of the sensor ...

Page 6: ...efault value is the Damoatech server add ress Measuring cycle Sensor measurement cycles settin g 15 to 180 minutes Temperature Offset 10 10 When the temperature does not fit set offset Active time settings after all settings are finished Set to 0 to minimize battery consumption Reset to reset time by setting the sensor to at least 10 seconds for resetting After submitting from all settings wait 12...

Page 7: ... 0 1 20 Ip address is set to the same because all sensors are Server SSID Name connected SSID Sensor Name Sensor name FarmCLO_ Sensor ID Sensor ID MAC without Server Address Enter the server address and Port you want to connect to and th en click Submit UUID It is specified automatically Don t enter Erase Network Delete network information change to default to all network infor mation Example ...

Page 8: ...ult value is the Damoatech server address Measuring cycle Sensor measurement cycles 15 to 180 minutes Temperature Offset 10 10 When the temperature does not fit set offset Sensor Calibration Sensor Initialization Must be removed from the soil do not touch pine and executed Active time settings after all settings are finished When using the battery Set to 0 to minimize consumption Always on power K...

Page 9: ...you must register your product The product buyer can inform us of the product warranty or the number affixed to the top Email address info damoatech com Please provide the buyer s name address email address and contact information User IDs and passwords will be notified at we will inform you ...

Page 10: ...be no problem connecting 1 1 without internet 3 Please try again to delete your current network information 4 If you try the above and you are not connected please send it to our headquarters 1 Switch at 11 o clock Power Reset button 2 Switch at 9 o clock button for Factory Reset 3 Press and hold the 9 o clock button and push and release the 11 o clock button 4 Release the 9 hour button when the b...

Page 11: ...Product Photos ...

Page 12: ...W Size 80 L x 120 H x 80 W Weight 120g Battery cable excluded Network interface WIFI 802 11b g n Frequency of use 2 4Ghz WIFI encryption WEP WPA WPA2 Moisture VWC 0 100 Soil temperature 40 70 EC 0 5000dS m Material Nylon66 GF30 SUS304 Warranty Period 1year Operating temperature range 20 70 KC Authentication Number R R dMt DT SMS01B ...

Page 13: ...d is time analysis 3 ADR method is amplitude analysis 4 The method used by DamoaTech uses a method of measuring dielectric permittivity like FDR 4 The moisture value of the soil sensor represents the relative value not the absolute moisture value of the soil 5 The Rural Promotion Agency and the Agricultural Fractalization Foundation FACT are also conducting tests by measuring only the amount of ch...

Page 14: ...ctual cost will be settled 2 Even within the warranty period the following cases will be paid and settled for actual expenses in accordance with the company s service regulations 3 If a foreign object is injected into the product and fails A If the product is damaged or functionally damaged by dropping or impacting the product B Failure occurs due to applied voltage outside the voltage range C You...

Page 15: ...omplies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation b Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment...

Reviews: