DAMM TetraFlex V7.6 Manual Download Page 1

 

 

 
 
 

 

 

TetraFlex

®

 V7.6 

 

(w. US remarks) 

Manual version 1.00 

 
 
 
 
 
 
 
  
                 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
The information contained in this document is the property of Damm Cellular Systems A/S. This document is 

subject to copyright and shall not be published or reproduced, in whole or in part, without the written permission 

of Damm Cellular Systems A/S.  

 

© 2010 Damm Cellular Systems A/S. All rights reserved.   

Møllegade 68, DK-6400 Sønderborg, Denmark  

Phone: +45 74 42 35 00, Fax: +45 74 42 30 31,  

E-Mail: [email protected],  

http://www.damm.dk

 

Summary of Contents for TetraFlex V7.6

Page 1: ...A S This document is subject to copyright and shall not be published or reproduced in whole or in part without the written permission of Damm Cellular Systems A S 2010 Damm Cellular Systems A S All r...

Page 2: ...e Station including additional units installation software and how to configure the system for operational use Remark TetraFlex ver 7 6 is not compatible with earlier versions Please follow the update...

Page 3: ...d Index all pages prior to page 1 1 and after page 4 x and insert these in the printed section IMPORTANT Updates changes important information related to the TetraFlex system and software may be downl...

Page 4: ...erated in a commercial environment The equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to...

Page 5: ...f Update guideline for ver 7 x to 7 6 5 TetraFlex 7 6 BS41x redundant setup pdf Redundancy sw setup guideline for BS41x 6 TetraFlex 7 6 SB421 redundant setup pdf Redundancy sw setup guideline for SB42...

Page 6: ...6 1 1 4 5 2 Switches 1 6 1 1 4 5 3 Interconnections board LED s 1 7 1 1 4 5 4 TR1 TR2 connection module 1 7 1 1 4 5 5 PS Connection to TR1 and TR2 1 8 1 1 4 5 6 LAN Connection to TR1 and TR2 1 8 1 1 4...

Page 7: ...deep discharge protect 1 33 PART 2 SW INSTALLATION AND CONFIGURATION 2 34 2 1 Basic system parameters 2 35 2 1 1 System capability 2 35 2 2 Virus protection 2 36 2 2 1 Introduction 2 36 2 2 2 Virus T...

Page 8: ...gle node 2 64 2 6 1 1 2 How does DHCP work with the SB421 BSC 2 64 2 6 1 1 3 Changing the BS421 IP 2 65 2 6 1 1 4 Static IP 2 67 2 6 1 1 5 TR421 Update Install 2 68 2 6 2 Installing Windows CE on BS42...

Page 9: ...ion 2 101 2 11 2 LogServer License 2 101 2 11 3 Logserver Tray Configuration 2 102 2 11 4 Log API 2 105 2 11 5 Log server Installation 2 106 2 11 5 1 Internal Log Server 2 106 2 11 5 2 External Log Wo...

Page 10: ...guration 2 142 2 16 3 4 TetraOM set up 2 142 2 16 3 5 TetraOM Help 2 145 2 16 3 6 TetraOM Editor 2 147 2 16 3 7 TetraOM logging 2 148 2 16 3 7 1 Logging to File 2 148 2 16 3 8 Some useful TetraOM Comm...

Page 11: ...2 Base Station Controller 3 172 3 2 1 BSC exe description 3 172 3 2 2 BSC GUI 3 172 3 3 Network Management 3 178 3 3 1 Network Management 3 178 3 3 2 Toolbar 3 178 3 3 3 NM menu 3 179 3 3 3 1 File 3...

Page 12: ...Configuration 3 237 3 5 3 2 1 Audio 3 237 3 5 3 2 2 Language 3 238 3 5 3 2 3 Calls 3 239 3 5 3 2 4 Map View 3 240 3 5 3 2 5 Mobile Positions Storage 3 242 3 5 3 2 6 SDS 3 243 3 5 3 2 7 External Devic...

Page 13: ...e TetraFlex Network and the Log Server 3 277 3 6 2 2 Log Server Tray 3 279 3 7 Log Client 3 280 3 7 1 Description 3 280 3 7 2 Functionality 3 280 3 7 3 Statistics View 3 281 3 7 3 1 Node 3 282 3 7 3 2...

Page 14: ...ation 3 319 3 8 3 Group Bridge Setup 3 320 3 8 3 1 Terminal Gateway Connection details 3 322 3 8 3 2 Tetra Radio Device connection details 3 323 3 8 3 3 Settings Piciorgros DVI 100 parameters 3 325 3...

Page 15: ...tion factor 4 357 4 5 3 BER versus input signal TCH7 2 4 358 4 5 4 MER versus input signal SCH F 4 358 4 6 Power Supply for BS41x 4 360 4 6 1 Introduction 4 360 4 6 2 Rectifier 4 360 4 6 3 14V and 26V...

Page 16: ...sions Numbers SW Ver Release Date Main Cause of change Author Approved 7 40 2 00 01 11 2009 Initial release Manual completely rearranged BUK JB 7 40 2 01 11 01 2010 Manual update see record BUK JB 7 4...

Page 17: ...ual so it will always be up to date regarding information and readability To do this DAMM needs to get feedback from you So if you as reader find anything which could be done better items which is not...

Page 18: ...ta Base DCK Derived Cipher Key DGNA Dynamic Group Number Assignment Dongle A USB dongle programmed by DAMM to be inserted in the node and or application PC The dongle controls which functions and appl...

Page 19: ...lier called Service and Maintenance Agreement SMA SNMP Simple Network Management Protocol Software package A package containing all functions and applications available on the release date SSI Short S...

Page 20: ...Doc No Rev Date 1 00 2013 01 04 Damm Cellular Systems A S Denmark TetraFlex 7 6 Manual SB421 Installation TetraFlex 7 5 Manual 1 1 PART 1 Hardware Installation...

Page 21: ...ecific customer defined operating temperature range from 40 C to 55 C ambient air temperature is optional upon request The Service Box encapsulation complies with IP65 1 1 2 Placement The recommended...

Page 22: ...D510 1 66 GHz 2 GB 8GB CF 2 2 4 Figure 1 1 SB421 Variants The above specifications are a minimum and may be changed according to availability of processors and storage media Any change in specificatio...

Page 23: ...rmation in section 1 1 4 1 Regarding the type and specification of the CPU board High performance or general performance dependent of the type of SB421 Figure 1 2 BSC421 1 1 4 4 1 SB421 Processor boar...

Page 24: ...NETWORK Red No Ethernet BSS Red No connection to BSS BSC Red No connection to redundant BSC ALARM Red Other BSC alarm present PS LINK Yellow Connected to PS MAINS Green Mains present CHARGE Green Bat...

Page 25: ...1 4 5 1 Connections o LAN TR1 and TR2 J31 o LAN WAN J32 o 48V PS J22 o 48V Internal external battery dependent of plug used J40 o TR1 and TR2 connection module J11 o LAN WAN SEC Alarm connection modu...

Page 26: ...N Figure 1 5 Interconnection Board 1 1 4 5 4 TR1 TR2 connection module The TR1 TR2 connection module is located at the LEFT bottom side of the SB421 interconnection board o 48V DC for TR1 J1 o LAN 1 s...

Page 27: ...Function BS421 Color ETH_IN 8 ETH_OUT 1 White Orange ETH_IN 7 ETH_OUT 2 Orange ETH_OUT 6 ETH_IN 3 White Green ETH_OUT 5 ETH_IN 4 Green SEC_IN 4 SEC_OUT 5 Blue SEC_IN 3 SEC_OUT 6 White Blue SEC_OUT 2...

Page 28: ...or further information 1 1 4 5 9 1LAN Connection Note LAN in out is used for redundant SB421 If redundant SB421 or multi node backbone is not used connect cable to WAN part only If environment permits...

Page 29: ...rovided with an appropriate fuse according to the selected mains supply voltage as to ensure a consumption of 4 5A 110V 2A 230V The cables used for the 100 240V AC and 48V DC to the base stations must...

Page 30: ...ttom of the SB421 REDUNDANT SB 421 3 4 CARRIER SYSTEM SYNCHRONIZATION OPTION 2 The interconnection board NB what is meant on the connector for the BS421 is marked with a label SYNCHRONIZATION OPTION 2...

Page 31: ...ending on the use and environment It is recommended that the battery is checked at least every second year and exchanged if necessary please see chapter Battery test SB421 1 1 6 1 1 SB421 Installing b...

Page 32: ...door cable assembly Figure 1 10 Cable assembly o Move the cable assembly to give access to the 1 nut holding the ground connection and the 4 threaded studs for battery base plate mounting o Carefully...

Page 33: ...s in such way that the threaded studs are fitting the holes of the battery holder NOTE Be careful to ensure the battery cable in placed on the outside of the battery holder o Mount and tighten the 5 w...

Page 34: ...or 1 Gnd Yellow 2 5V Brown 3 Data Red 4 Data Blue Figure 1 13 Temperature sensor Note If an internal battery kit is mounted pull out the battery connector J40 for the internal battery and insert the f...

Page 35: ...from 40 C to 55 C ambient air temperature is optional upon request The Base Station encapsulation complies with IP65 1 2 2 Placement The recommended placement of the Base Station is as close to the an...

Page 36: ...her with the USB connector allows a connection of a standard monitor and mouse keyboard connection If monitor keyboard and mouse are connected the WindowsCE operation system in the BS421 can be access...

Page 37: ...The BS421 will function with only Tx Rx A and without GPS antenna with the following limitations Timing via GPS will not be available BS421 runs on internal oscillator Not recommended and there will...

Page 38: ...ety Extra Low Voltage The provision of power is done via the SB421 TR1 TR2 connection module See the SB421 installation section for information on the connection pin out for SB421 DO NOT UNDER ANY CIR...

Page 39: ...nals NOTE Cable used must be 0 4mm2 to 0 6mm2 24AWG solid cores Function SB421 Function BS421 Color ETH_IN 8 ETH_OUT 1 White Orange ETH_IN 7 ETH_OUT 2 Orange ETH_OUT 6 ETH_IN 3 White Green ETH_OUT 5 E...

Page 40: ...v Date 1 00 2013 01 04 Damm Cellular Systems A S Denmark TetraFlex 7 6 Manual BS421 Installation TetraFlex 7 5 Manual 1 21 1 2 6 1 1 Easy connection scheme See the SB421 installation manual for furthe...

Page 41: ...all the BS in rooms with controlled environmental conditions in order to optimize its reliability and lifetime It is important that the room is free of dust Condensing humidity is not allowed The Base...

Page 42: ...stment 1 3 3 Grounding The BS requires careful grounding For temporary operation the mains earth connection can be used For permanent installations an effective ground shall be established and connect...

Page 43: ...ems The following antenna cables shall be attached If the jumper between ANTA and RXOUT is NOT connected Separate RXA RXB and TX antennas o 3 cables to the TMD412 two RXA and RXB and one for Test o 1...

Page 44: ...r on TETRA Green Tetra Mode on TX Green Transmit power on NMT Green NMT mode not used in TetraFlex LB Red Local Blocking on TX Red Transmitter alarm RFTL Red RFTL output active used for testing RX Red...

Page 45: ...a switch is placed on the back plane of the BS to indicate to the PS411 s whether a 48V or 60V battery is used Note that the present version of PS411 can only operate with 48V DC wherefore this featur...

Page 46: ...us pole not is connected to ground then the connection to the DC mains supply shall include a disconnection device which disconnects both poles simultaneously otherwise there shall be a disconnection...

Page 47: ...it is recommend to leave it open Figure 1 26 Mains connection block Note Each of the installed power supplies are individually connected to the AC mains therefore in order to disconnect the Base Stat...

Page 48: ...1 LAN2 and BSC2 LAN 2 is for local connection ex a Local PC for service and monitoring etc BSC1 WAN1 and BSC2 WAN1 are for connection to corporate network SIP units Remote desktop Switch board PABX Di...

Page 49: ...are protected for inductive transients with 36V zener diodes The alarm connections are provided with LSA type connections accepting solid wires with the dimension 0 4mm2 to 0 6 mm2 1 3 9 Back up batte...

Page 50: ...perature The batteries should also be of the gas tight type when co located with the BS to avoid corrosive gases which may damage the electronics A battery capacity of 48V 50Ah would be a typical choi...

Page 51: ...uld be connected to the plus pole of the battery The Base Station itself and optionally the battery shall be provided with an effective grounding The TS411 temperature sensor shall be located at the b...

Page 52: ...o switch off the load when the battery is close to being discharged in order to protect the battery The Base Station is prepared for 60V battery operation wherefore a switch is placed on the back plan...

Page 53: ...Doc No Rev Date 1 00 2013 01 04 Damm Cellular Systems A S Denmark TetraFlex 7 6 Manual Basic system parameters TetraFlex 7 5 Manual 2 34 PART 2 SW Installation and Configuration...

Page 54: ...software parameters of the system but they can be increased on request The max numbers can be decreased by dongle setting Readout can be done with TetraOM command and the Dongle Reader program The sy...

Page 55: ...the internal LAN area 2 2 2 Virus Threat The major threat for a system is that viruses will infect the system components with WAN access These components will either be a Damm BSC running Windows or...

Page 56: ...but AVG does not accept the product code of Windows Embedded and DAMM has not succeeded to get AVG to implement the needed changes 2 2 3 MS Security Essentials Microsoft has recently released their n...

Page 57: ...equipment 2 3 1 2 Dongle types NOTE TetraFlex V7 20 and forward require a new type of dongle If no encryption key is required in the dongle it is possible to order a number of empty spare dongles and...

Page 58: ...Streams max o Air Interface Encryption o Air Interface Encryption KSG An API Client dongle is programmed with o Dongle Date Limit o Dispatcher Yes No A Log Server dongle is programmed with o Dongle D...

Page 59: ...1 Log workstation Log server PC From TetraFlex ver 7 6 Requires a Dongle with Present or not flag PC Non DAMM delivery Android Client Smart Phone or other device Non DAMM delivery General license opti...

Page 60: ...he serial number of the faulty missing dongle and DAMM will send a mail with a file containing the System and Node license s settings from the original dongle o An invoice will be issued with the valu...

Page 61: ...r investigating dongles In the top of the Dongle reader program there is a number of tabs that show what contents the dongle has The Dongle tab is always present If a tab is set to None there isn t an...

Page 62: ...Flex 7 5 Manual 2 43 Dongle o DAMM serial number the dongle hardware number can be read by S04 I o Brand in this case DAMM TetraFlex OEM version are available o Language o Key Ref Serial number and if...

Page 63: ...ll o Voice Gateway Conn max Maximum telephone connections per node o Packet Data Gateway Packet data allowed or not o Application Conn max Maximum application connections API interfaces o Air Interfac...

Page 64: ...operation when the specified date is reached o Application Date Limit The License Dongle check date is compared with this date for SW update allowance o Call Info Log Call information logging CDR set...

Page 65: ...set discreet listening into an ongoing calls is possible on the API e g when using the dispatcher Ambience listening if flag is set ambient listening is possible on the API e g In the dispatcher o App...

Page 66: ...t can be setup in the Group Bridge o Analog conn Max The max numbers of Analog radio devices that be defined in the Group Bridge 2 3 1 7 Partners access to Software Releases o Any Partner with access...

Page 67: ...n be implemented together with the new Software Releases at an appropriate time 2 3 1 8 Programming of Dongle Application Date Limit This setting is subject to change without notice o The Application...

Page 68: ...2 4 1 CF Storage media The TetraFlex system uses an 8GB Compact Flash CF Card as storage media The CF card is divided in to 3 partitions 8GB CF Card Order no 105126 V7 30 and forth Partition No Name...

Page 69: ...l state which version is initially delivered Be aware that it is a violation of license to upgrade an XPe OS with WES2009 unless a new license is purchased from sales A WES2009 can legally be downgrad...

Page 70: ...d to a 8GByte CF card with the full TetraFlex packet including a preinstalled Log Server The actual TetraFlex configuration should be copied from the old to the new CF card the configuration is stored...

Page 71: ...ted the first time the BSC exe is started o To prepare the BSC service for starting make a copy of bsc exe to bsc_ exe o For installing the BSC service run BSC vbs with the parameter INSTALL The syste...

Page 72: ...Windows installation the following files should be executed If not already there the files could temporary be placed in the following path C Tetra Active pgm BSC o XpQosSetup reg o WinPcap_4_0_1 exe o...

Page 73: ...line for ver 7 x to 7 6 Having an OM shortcut on the desktop change it to point at C Tetra Active pgm OM OM vbs 2 4 4 4 NM Stop the NM program when running 1 If the system is installed with TetraFlex...

Page 74: ...in any of the above mentioned folders e g from older installations please delete them before copying the new Dispatcher installation files When re starting the BSC a Dispatcher distribution point is...

Page 75: ...x log client 2 4 4 7 Log Client The Log Client applications may be installed on an external PC work station with the appropriate dongle Install the Log Client by connecting to the Log Server on SB421...

Page 76: ...the new TR421 dll On the local BSC execute the BS421Download bat file Path C Tetra Active Pgm TR421 Restart all the TR s by help of TetraOM commands 99 RESTART 2 4 4 11 Installing TEA2 encryption File...

Page 77: ...ns are protected by arresting devices The Ethernet connections are limited to SELV The Ethernet WAN connection is connected to an Ethernet switch or directly to the PC Network by means of a straight o...

Page 78: ...NOTE In case of an internal hard disk is present disable this totally before booting from the CF card After initial boot the HD may be enabled again and should appear as D drive with a 2GB CF card ins...

Page 79: ...No Rev Date 1 00 2013 01 04 Damm Cellular Systems A S Denmark TetraFlex 7 6 Manual SB421 Configuration TetraFlex 7 5 Manual 2 60 Figure 2 3 Boot configuration Figure 2 4 Advanced and Advanced CPU Cont...

Page 80: ...guration TetraFlex 7 5 Manual 2 61 Figure 2 5 Advanced Video Intel IGD Control and advanced Integrated Device Control Figure 2 6 Advanced I O Device Configuration and Advanced Clock Control Figure 2 7...

Page 81: ...also a PS alarm may show on the BSC LED s o WAN Network Card DHCP 2 5 1 5 MAC address Set up On delivery from DAMM the MAC is set to the correct value BSC s delivered from 01 01 2008 has the MAC addr...

Page 82: ...Start MacMakeUp Application o In the MacMakeUp application select the 8255xER PCI Adapter o Enter the MAC address Enter value like 000FE3000431 o Press Change o Close the application o Re open MacMak...

Page 83: ...units are an integrated part of the SB421 2 6 1 1 Set up of IP address 2 6 1 1 1 DHCP Typical TetraFlex single node The IP address and the net mask is setup by means of DHCP When the system is delive...

Page 84: ...ess to 172 16 1 11 o If more IP s are shown and only one BS421 is connected determine which IP address is valid by use of a ping command to the IP s Delete the wrong IP MAC entries and change the rema...

Page 85: ...ially off line DHCP server stopped To stop the DHCP server log in to C ProgramFiles DHCPserver and double click on the dhcpsrv exe file Figure 2 11 DHCP Redundant Setup Then select STOP to temporarily...

Page 86: ...rk and dial up connections o Open the AU1MAC1 o Select Specify an IP address and enter the relevant data into the fields o Select OK and exit the program Figure 2 12 Static IP setup o Check SB421IP se...

Page 87: ...used BS421 s echo Copy files to TR421 1 net use Z 172 16 1 11 CF Card tetra USER tetra PERSISTENT NO copy TR421 dll Z Tetra Pgm Tr Y copy TR421 bat Z Tetra Pgm Tr Y net use Z DELETE rem echo Copy file...

Page 88: ...stem on BS421 is Windows CE that is contained in one file NK bin this chapter describes how to install it IMPORTANT Do not copy NK bin WinCE to the BS421 unless instructed to do so or forced to do so...

Page 89: ...elect CF Card o Create a new directory called CF Card TMP on the BS421 o Copy the file NK bin from SB421 C tetra PGM TR to the CF Card TMP on BS421 o Open VNC for TR1 or TR2 from the desktop o Open My...

Page 90: ...Configure admin user When a new NK bin file has been copied to the BS421 the BS421 Admin and User settings are lost To reestablish follow the procedure o Start the Internet Explorer from SB421 Start P...

Page 91: ...rt BS421 BS421 serial number o Press Apply To move on it might be necessary to temporarily make a change to the Device Name and press Apply Immediately change it back to the original name and press Ap...

Page 92: ...Figure 2 16 Configure user and password 2 6 3 Copy to and from Compact Flash Card CF Card on BS421 o Use Explorer to connect to BS421 o Start Search For files or folders Computers o Enter TRx IP addre...

Page 93: ...SC GUI or using OM command BSC GUI Select the BSC tab and click on the TR s configured menu and then add the TR When clicking Ok the setting is saved TetraOM connect to the BSC Perform the following c...

Page 94: ...abel is v1 HW version v2 and forth has the possibility to change the setting via the TetraOM program This change is required to ensure correct BSC handover and synchronization of the carriers The chan...

Page 95: ...21 is provided with one External 1PPS 1 Pulse Per Second output and two external 1PPS inputs The Slaves shall receive external 1PPS inputs connected to Masters In addition to the hardware 1PPS sync me...

Page 96: ...ter Mode 3 Ext Master 2 Master Mode 4 Int GPS RX 5 Ext Master 4 Master Mode 6 Ext Master 0 7 Ext Master 1 8 Ext Master 2 9 Ext Master 4 Resync only 10 Int Free Run Master 4 priority 1 Ext Master 0 Mas...

Page 97: ...TR s Typical 1 carrier BS421 configuration TR11 Master 1 OM command 72 MASTER 1 Typical 2 carrier BS421 configuration with GPS on both carriers TR11 Master 1 TR12 Master 2 TR11 OUT connected to TR12 I...

Page 98: ...frequency adjustment procedure If the BS is operating without GPS sync Free run the reference oscillator has to be checked and adjusted one time a year Measure the BS421 transmitter frequency the tran...

Page 99: ...f the PS411 Power Supplies will flash until they receives configuration from the BSC 2 7 2 Special precautions NOTE Batch commands B are not supported on TR411 and TR412 using the HDLC bus 2 7 3 Set u...

Page 100: ...SC GUI or with OM commands Both are described in this chapter The BSC GUI can be started from the Start menu TetraFlex BSC BSCGUI The Transceivers can be added and deleted from the BSC tab OM command...

Page 101: ...uration can be done from the BSC GUI BS tab Select the desired TX antenna alarm and make the changes OM Command F73 TXANT xx yy z z 0 nn Where xx reflects TX antenna level 1 alarm setting 06 to 16 dB...

Page 102: ...e rack during normal BS operation Before it is inserted or removed be sure that both switches on the front plate are in OFF position The PS411 automatically receives the configuration from the BSC at...

Page 103: ...ound 20dBr 3dBr a lower value may indicate a bad receiver antenna or cable Set local blocking to off again 01 Local blocking off 2 7 10 Save BSC and TR configuration The various settings are from Tetr...

Page 104: ...ating the TetraOM System requires a PC to be connected to the BS a screwdriver and a short test cable The test cable must be a 50 cm long RG214 cable with two N male connectors 2 7 11 3 Adjustment Pro...

Page 105: ...te the feeder loss o Register the RSSI on the TMA input If step 1 and 2 has been done correctly the reading should be 105dBm if the cable losses are 8dB If the cable losses are less than 8dB the input...

Page 106: ...W mode for easier measurement Commands to TR412 01 Local blocking 02 Test mode 15 CW CW modulation 10 Start transmitter Commands to adjust the reference oscillator H31 Display Sync status note the DAC...

Page 107: ...C1 OM command M71 DESCR NODE5 BSC1 The string should contain a description of the node or the geographical position of the BS site If it is a single carrier BS with directional antenna the direction c...

Page 108: ...coordinates of the Node This will be overwritten with the actual GPS position if Position change from GPS allowed is set to Yes OM command H71 POS 54 54 55 54N 009 48 23 69E All settings are saved imm...

Page 109: ...ect the TX BS power normal For the BS41x the setting is Tetra Mode output power at Rack TX Antenna connector An insertion loss of the combiner system of 4 0dB is assumed If the value is lower or highe...

Page 110: ...ngs for BS41x and SB421 TetraFlex 7 5 Manual 2 91 2 8 3 BS Power reduced The Tx output can automatically be set to reduced power value as set in BS power reduced The reduced level is activated when Di...

Page 111: ...a monitor connected direct to a SB421 or a BSC412 You can also use a PC which has an IP connection to the infrastructure The NM is able to listen to the multicast which means when using a PC the PC m...

Page 112: ...atus variables whilst the SNMP agent will service the SNMP requests The SNMP Management Application polls for the node status Traps are not generated by the TetraFlex network This is in accordance wit...

Page 113: ...C Tetra Active Pgm NM 3 Run the SNMP_install vbs file to install the SNMP extension dll and registry settings 4 Start up the Network Management application NM NM should be set to auto start to start...

Page 114: ...in the startup folder to make the Network Management application startup automatically upon boot 7 Check the SNMP Security settings start right click on my computer manage Services and Applications Se...

Page 115: ...n tested to work with WatchUp Gold 14 2 The following figure is a graphical representation of the DAMM GLOBAL MIB module The Damm MIB tree Figure 19 The DAMM GLOBAL MODULE The most important variables...

Page 116: ...bscriber dammRoot 3 1 1 2 1 6 Subscriber alarm 0 OK 1 Warning 2 Alarm 3 Blocked 255 Not configured alarmRadio dammRoot 3 1 1 2 1 7 Radio alarm 0 OK 1 Warning 2 Alarm 3 Blocked 255 Not configured alarm...

Page 117: ...ion For API installation please refer to the Application Gateway installation section 2 10 2 Dispatcher Installation The Dispatcher can only be installed outside the BSC on a separate PC It connects t...

Page 118: ...If using Install dispatcher for user number the user Application SSI number and PIN code that has been setup in the subscriber register must be typed in in this case the Dispatcher is installed in th...

Page 119: ...me profile How to do it Enable network discovery Turn on file and print sharing Turn off password protected sharing Use user accounts and passwords to connect to other computers 2 10 4 Configurations...

Page 120: ...l log server is factory set to be disabled and has to be enabled and started from the TetraFlex menu Logserver install 2 11 2 LogServer License The TetraFlex Log Server requires a USB License dongle t...

Page 121: ...inate logging Max number of concurrent voice logging channels Number of simultaneous voice channels which can be logged at a given time 0 255 2 11 3 Logserver Tray Configuration The TetraFlex Log Serv...

Page 122: ...the multicast group where the control messages flow default 224 239 16 1 and Port default 42400 LogServer multicast control IP receiving This is the multicast IP address of the multicast group and Por...

Page 123: ...setting allows logging of voice of non configured MS subscribers in the LogServer when enabled If a MS has been configured in the LogServer it will use these values regardless of this setting When thi...

Page 124: ...ch can be used for testing the Log API This can be requested from DAMM support Every UDP message contains a common message header The byte order is Little Endian Supported features Status messages SDS...

Page 125: ...menu TetraFlex LogServer LogServer Install This will start the MySQL service Log server application and the log server tray This also will create a new empty database if not already created 2 11 5 2...

Page 126: ...g to identify it Right click and select Rename from menu name it WAN Set the Connection type to Home or Work private networks 2 Disable Automatic updates Go to Control Panel System and Security Window...

Page 127: ...t Keep the Check mark in Detailed configuration click next Depending on the machine select either Server Machine this is for a BSC or Dedicated MySQL Server Machine this is for LogServer running on PC...

Page 128: ...d from www damm dk extranet by downloading the latest Tetraflex 7 6 version Please read the release notes before installing 9 Install the Log Server Ensure that the IP settings are correct for LAN and...

Page 129: ...tions 10 Add rule for firewall Go to Control Panel System and Security Allow a program through Windows Firewall Select Allow another program Browse to C Tetra Applications LogServer LogServer exe Allo...

Page 130: ...L Server used is a MySql server The MySQL Community Edition is a free downloadable version of the world s most popular open source database that is supported by an active community of open source deve...

Page 131: ...o A law and vice versa when running on the standard BSC412 platform and up to 15 simultaneous speech connections when running on a standard BSC421 platform Up to 32 simultaneous speech connections are...

Page 132: ...ex 7 5 Manual 2 113 2 12 1 Voice Gateway configuration This section describes the configuration needed to setup the system for SIP operation To configure a Voice Gateway use the TetraFlex NM applicati...

Page 133: ...files where PABX access is desired or by using the TetraOM command S21 Profile No VGNODE x Node Number where x is 1 for primary GW and x is 2 for alternate GW Organization can be set from the Voice GW...

Page 134: ...IP800 but may be any SIP compatible device The status of Voice GW can be verified using the BSC GUI or with the OM command S13 Figure 2 20 Voice Gateway Status 2 12 2 Innovaphone IP800 Configuration...

Page 135: ...his license is not present the selection Gatekeeper Registrar will not be shown If IP800 GW license is not present it is possible to connect without registration In this case the WAN port IP address m...

Page 136: ...2 12 2 2 IP 800 Route table example Please note that this example shows an IP800 which serves as gateway for several TetraFlex systems Figure 2 24 Route table example Dialing 724000 will be transform...

Page 137: ...n the profile for the mobiles allowing mobiles to use their company DNS Server By default the TetraFlex Packet Data gateway automatically announces itself to the connected IP segment with the RIPv2 pr...

Page 138: ...ed Yes or No is PD GW active RIPv2 If Yes RIPv2 is used If No Static routing is used Active mobiles count Numbers of active mobile connections o TetraOM Activate the packet data gateway using S74 CNFG...

Page 139: ...st be set from the Config dialog From the Network Management configure a packet Node attachment if not already done via TetraOM This is done from setup in the subscriber register in the different prof...

Page 140: ...teway TetraFlex 7 5 Manual 2 121 In the profile make sure the DNS IP address is configured and the packet data GW 1 node number is configured If the MS is to be used for packet data transfers make sur...

Page 141: ...ows is finished configuration select properties on the modem connection Setup the Maximum Port speed to 38400 bps 2 13 2 1 Network configuration o From the Control Panel open the Network Connections o...

Page 142: ...3 01 04 Damm Cellular Systems A S Denmark TetraFlex 7 6 Manual Packet Data Gateway TetraFlex 7 5 Manual 2 123 2 13 3 Main router For incoming attempts make sure a static route is configured for the pa...

Page 143: ...andling the complete interface protocol The TetraFlexApi dll will also take care of its basic configuration and the Voice interface to PC sound system The TetraFlexApi dll is License Dongle protected...

Page 144: ...ays work together with GUI Applications written for earlier versions 2 14 4 API Test applications The SW package also includes an API toolkit SW programmed in C C and Delphi for testing the different...

Page 145: ...er register Create an application subscriber SSI and enter the relevant Application data Figure 2 26 Application Subscriber The API application e g DAMM dispatcher can either use the User No or the TS...

Page 146: ...11 01 14 29 43 71 Common 71 IDPROMPT 71 USERNO 1700522 71 PIN 4711 71 OMPORT 42382 71 OMPIN 1841803245 72 Gateways 72 0 010 239 016 200 TetraStar 72 1 72 2 72 3 72 4 72 5 72 6 72 7 72 8 72 9 Figure 2...

Page 147: ...E g of dongle settings for using the API DLL Figure 2 28 Node dongle Figure 2 29 Client Dongle To allow communication between the API DLL and a Node the Node Dongle must have the Application Gw Conn M...

Page 148: ...onfig and subscriber 71 PIN 4711 PIN If used must also be defined in subscriber reg 71 OMPORT 42382 Access port for TetraOM cannot use 42380 71 OMPIN 2081304613 TetraOM pin code that must be entered f...

Page 149: ...be initiated 2 14 9 1 API test tool The API test tool can be downloaded from www damm dk extranet and is available in a C version and in a Delphi version The API test tool must be in the same directo...

Page 150: ...l result in a message showing that the API is connected Figure 2 32 C Test API connection 2 14 9 1 2 Test via API OM To be able to connect to the API via TetraOM the API must be initialized as describ...

Page 151: ...Flex 7 5 Manual 2 132 Figure 2 34 API connection status o Enter Pin Code find the PIN code in the config txt file o TetraOM command 01 L R 01 L for dynamic will show the connection status 2 14 9 1 3 U...

Page 152: ...r Systems A S Denmark TetraFlex 7 6 Manual Application Gateway TetraFlex 7 5 Manual 2 133 Figure 2 35 GUI Window o In the Subscriber header press or TetraOM command 30 SUBSCR GUI the GUI configuration...

Page 153: ...y Group Bridge TetraFlex Client WAN The Terminal Gateway can be compared with the Application gateway but with reduced functionality and it does not require an API dll on the client site The Terminal...

Page 154: ...Cellular Systems A S Denmark TetraFlex 7 6 Manual Terminal Gateway TetraFlex 7 5 Manual 2 135 BSC Gui The same parameters can be set from BSC GUI OM Commands See help file for OM commands regarding th...

Page 155: ...Application Gateway the Group Bridges and TetraFlex Clients that want to connect to TetraFlex using the Terminal Gateway must be set up in the Subscriber register For the Terminal Gateway client a Te...

Page 156: ...ferred to in this document as the BSC For a complete list of TetraOM commands see the TetraOM help files manual or the on line help in the OM Several methods of communication are available depending o...

Page 157: ...e TR412 s combiner and Power supply is not possible and must be made via the HDLC bus To activate the HDLC bus UART use TetraOM command AU If for some reasons the HDLC cannot be activated use AU FORCE...

Page 158: ...41x consist of a 2 digit command in the range 00 to 99 with an optional parameter Commands without parameters are display only commands and will not make any changes Therefore it is possible to page t...

Page 159: ...tual time date and century seconds C 63 N Shows the GPS data stream from a BS421 2 16 3 1 4 Simultaneous commands From the TetraOM terminal window it is possible to combine several TetraOM commands us...

Page 160: ...s used as parameter to turn off disable or step down E g 11 turn power supply on 11 turn power supply off For more complex functions a is used as separator after the command no followed by the necessa...

Page 161: ...uration o Factory configuration only to be done by DAMM System configuration parameters can be changed with the 7x OM commands and are automatically saved 2 16 3 4 TetraOM set up More possibilities ex...

Page 162: ...the connection into some well defined name As an example this syntax might be used System Number Node Number Unit Description Organization E g TF24 S004 BSC1 Support To make a new connection push the...

Page 163: ...dow When connected the TetraOM communications window will appear Normally this window will be a black command screen with a welcome text or an error message if some commands have failed Communication...

Page 164: ...will soon be familiar For more rarely used commands a help system is available documenting all available commands and options The HELP is accessed either by pressing F1 or by clicking on the Help butt...

Page 165: ...2 41 OM Help After selecting a device a list of all available commands is shown Figure 2 42 OM Help After selecting a specific command an execution window appears In this window the command syntax is...

Page 166: ...t to save 70 SAVE or F70 SAVE for the BSC 2 16 3 6 TetraOM Editor The TetraOM program also contains an Editor where command files may be edited When the editor is active commands from the help system...

Page 167: ...me lan This will only work if the TR is allowed to logon to the host it might be necessary to go to the TR with VNC and type the user name password and domain of the host BSC or PC to get access o 48...

Page 168: ...he TetraOM main form and chose logging o Browse to enter destination and filename o Click only terminal responses to collect the message responses exchanged between the TR PS Combiner and BSC o Type t...

Page 169: ...6 Terminal GW status S20 Subscriber registers S20 SAVE Save actual register to text file S20 READ Load data from text file S21 Subscriber profile S21 nnnn Show profile nnnn S22 SSI Register Status S65...

Page 170: ...king Alarm can be changed to non blocking with command 71 TXREFLWAR 08 TX ant reflected L1 Non Blocking Alarm 10 RX PLL unlocked Blocking Alarm Hardware fault 11 RX LO1 injection low Non Blocking Alar...

Page 171: ...12 OM command 03 A Comment 00 TX PLL unlocked Blocking Alarm Hardware fault 02 TX VSWR protection Blocking Alarm Hardware fault 03 TX temperature high Blocking Alarm TR412 temperature over 80 C TX sto...

Page 172: ...x 7 6 Manual TetraOM TetraFlex 7 5 Manual 2 153 16 36 864MHz PLL 8kHz Blocking Alarm Hardware fault 17 1sec missing 18 L3 Frequency Setup Non Blocking Alarm 19 DSP watchdog Blocking Alarm 20 DSP Time...

Page 173: ...a standard provided with a VNC Server to allow one user at a time to establish a remote desktop session with the BS421 To establish a remote session start VNC on the Windows computer If it does not co...

Page 174: ...directory The files on the BS are now accessible for an instance the CF Card directory contains all SW for the BS You can now operate the Windows CE on the BS remotely from your computer 2 17 2 File...

Page 175: ...General setup and Sync Pressing the tool icon will show a toolbox where it is possible to setup general parameters o TR number o TR ID string o TX output o RX B input 6dB diversity preamble o BSC conn...

Page 176: ...nd Anycast RP The configuration for multiple RP and Anycast RP is not covered by this manual Please consult Cisco representatives to obtain guidance on this topic 2 18 2 Network layout principle As op...

Page 177: ...18 3 Backbone network physical connection 2 18 3 1 Outdoor SB421 Installation of connection to router backbone for multinode TetraFlex is done via terminal points LAN_IN and LAN_OUT on the LAN WAN co...

Page 178: ...ion and for signaling of call activity between BSCs in the TetraFlex network The address can be changed to meet special requirements 224 239 016 000 28 results in a address of 224 239 16 1 for exchang...

Page 179: ...es it possible for all the BSC s to decide whether a given call is relevant to any terminal under its control At same time the originating BSC will assign a CMoIP address to the actual call and send a...

Page 180: ...to the router This is done by using the command tool or DOS prompt if you wish to enter a persistent routing to the LAN interface Use the Start Run in the start menu and type cmd This will open the co...

Page 181: ...e entry NOTE Adding persistent route is not applicable when using switched network i e without routers involved 2 18 5 Considerations about network bandwidth When designing a backbone network for the...

Page 182: ...incoming outgoing pattern will change according to which node has the PTT activity 2 18 5 2 Full duplex Full duplex call is point to point In TetraFlex it is still transported as multicast The full du...

Page 183: ...tra codec Multivocoder support allows the use of G 711 linear codec also Where ACELP is a 7 2 kbit s codec the G 711 is at 64 kbit s This will increase the load from CMoIP with a factor 8 1 seen at th...

Page 184: ...e TetraOM to connect to the BSC locally Issue command F71 to check the local settings for the IP connections The command will list the LAN and WAN IP addresses which are set in the BSC Make sure these...

Page 185: ...with the TetraFlex multisite system Other router types and brands may be applicable But in case the router type is not Cisco Damm Cellular Systems A S will not be able to offer any support 2 18 9 App...

Page 186: ...ackets on all interfaces belonging to a multicast group except for the receiving interface A sub configuration of PIM is PIM Sparse Mode PIM SM This version explicitly builds unidirectional shared tre...

Page 187: ...s If you know the IP address of one of the Ethernet ports on the router you can also telnet into the router and use the same CLI The configuration of any Cisco router can be exported from the router a...

Page 188: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex General system description TetraFlex 7 5 Manual 3 169 PART 3 TetraFlex Applications...

Page 189: ...nctions and Applications are available on http www damm dk restricted area in encrypted form for a period of minimum 18 months after Release Date o All Software Releases consist of o Software package...

Page 190: ...ral system description TetraFlex 7 5 Manual 3 171 If the End User decides only to execute some of the files in the package he must check the release note for the new release against the release note f...

Page 191: ...y to the detected hardware platform The BSC exe service contains all the functions needed to run a complete Tetra system including Subscriber Register with Security Key Register Radio Cell Voice Gatew...

Page 192: ...sion Status se figure 3 1 gives an overview of the status of the BSC TR Transceivers and PS Power Supply s It is possible to clear alarms access the OM command system Activate BSC and BS Only BS41x Re...

Page 193: ...traFlex 7 5 Manual 3 174 The Clear Button deletes the actual content of the console window MAIN From the Main window the fundamental parameters for the BSC can be set and displayed The corresponding O...

Page 194: ...raFlex 7 5 Manual 3 175 The LAN and WAN address can be selected from the actual IP setting in Windows and the input of GPS data can be enabled and disabled yes no If GPS is enabled the GPS coordinates...

Page 195: ...ts with S e g S00 The settings are stored in c tetra active data CnfgBss txt The corresponding parameters can be set in NM so please find the explanation for the various parameters in the chapter cove...

Page 196: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Base Station Controller TetraFlex 7 5 Manual 3 177...

Page 197: ...dicates that most of the functions in the NM may be executed in the OM using the appropriate OM command The Network Management NM software may be executed on any PC which has an IP connection to the i...

Page 198: ...al 3 179 o Command Line Refer to section the next section o Graphical tools Refer to section 3 3 4 3 3 3 NM menu Figure 3 4 NM command line The command line has 4 selections o File o View o Tools o He...

Page 199: ...3 5 Network The options menu allows the choice of Local IP Multicast group IP and multicast port number For multicast settings please refer to the Multi Site IP networking manual The Local IP must al...

Page 200: ...nual 3 181 Specifies the path to log client application Figure 3 7 Log Client path setup o Remote Desktop Allows configuration of the Remote Desktop Figure 3 8 Remote desktop setup o Language When ena...

Page 201: ...aFlex 7 5 Manual 3 182 o Security Two security settings that allow or disallow users to make changes in System Parameters and Subscribers from NM Figure 3 10 Security setting o Alarms Configuration of...

Page 202: ...r fast Access and information overview Figure 3 12 Application select and alarms The Graphical tool for fast selection has 7 access icons and 5 notifications NOTE the Node Map and Status windows are l...

Page 203: ...ng alarms present o L2 Alarm Number of level 2 non blocking alarms present o L1 warning Number of level 1 warnings present o Ok Number of nodes that are ok without alarms If one of or more Alarms are...

Page 204: ...n the system When Left Mouse Click is executed on a node line the Node Status window displays the chosen node Redundant BSC s are not shown in the Node list but in the Node Status window and the BSC l...

Page 205: ...node with new SW previously deployed to the Tetra Update library and restarts the node o Backup Update restart Backs up the node and the updates the node with new SW previously deployed to the Tetra...

Page 206: ...emove node If a node is deleted but still active the node will reappear in the list after a short time o Clear alarms Latched alarms may be cleared o Acknowledge The alarm sound is shut off o Unacknow...

Page 207: ...raOM application o Remote Desktop o Windows Explorer o Restart of the BSC exe o Clear alarms If a standby Redundant BSC exe is present o Restart of Standby BSC exe o Activation of Standby BSC exe 3 3...

Page 208: ...may be chosen by the tabs in the top of the window Information that are not grayed out may be reconfigured by selecting the appropriate fields using right or left mouse button This setting allows see...

Page 209: ...mouse click on the following items allows the change of the configurations o Description Node description E g In the format System Node number Placement This description is collected and saved in the...

Page 210: ...mum time a call setup takes using the longest delay in the system can be set from 200ms to 2550ms Used to extend the node timeout E g when using satellite connections with long delays saved in CnfgBss...

Page 211: ...the system Stand alone For test and installation purposes Key Activation of the Security Key Register Further information in grayed out fields refer to the count of the different subscriber types pre...

Page 212: ...ollowing items allows change of the configurations o Log Server Log server Multicast control receiving IP address default 224 239 17 1 Log Server Multicast port default 42400 The following is informat...

Page 213: ...ed at the node o MCCH Main Control Channel by right click you can see the appropriate frequency o AIE Air interface Encryption off on o Sync Neighbor Cell Synchronization Shows Yes or No depending on...

Page 214: ...Handover settings Auto Yes No Auto means automatically sync setting e g GPS sync Sync must be enabled on each node to make seamless handover o SCCH Setup of 1 to 3 secondary control channels SCCH o Fa...

Page 215: ...izes the effect of power reduction P MIN 30dBm 23Bm 55dBm MIN 30dBm 32dBm 30dBm No power reduction yet o RDT Radio Downlink Timeout This it is a measurement of the downlink quality The higher the RDT...

Page 216: ...R operation or TR Hot spare witch in case of a TR fault will switch to the spare TR with the same Freq settings o RX frequency Receive Frequency setting o TX frequency Transmit Frequency setting o Car...

Page 217: ...tc Right mouse click on the following items allows change of the configurations Mode Change between Auto All cells and Selected cells only N1 to N16 Neighbor cell setup for the specific node The follo...

Page 218: ...alarms Call Number of active calls Idle Number of free GW Block Number of blocked GW The drop down box Active GWs All nodes changes between display of active nodes only or both active and not active...

Page 219: ...is optional and can be generated by the OM command S73 PASSWORD password e g S73 NAME blank means no password You can also set the Password with the BSCGui BSS VoiceGW The password must be entered int...

Page 220: ...Note Use of Packet Data GW s must be set in the Node Dongle Right mouse click on the following items allows change of the configurations Active Gateway activated can be deactivated by right clicking...

Page 221: ...Conn Max Max connection count can be changed by right click on it up to the max in the dongle One Dispatcher connection is one connection Streams max Max number of circuit streams for all connections...

Page 222: ...bers and 150 000 in Optional enhanced ver Sec Key Security Key Update The relation between Organization profile and SSI is shown in this drawing Organization 0 1 Organzation 1 Organization 2 Organizat...

Page 223: ...dependently Organization 0 is intended for the network operator and this Org can see all other organizations It is also possible to connect Profile SSI to org 0 but this should be used for network adm...

Page 224: ...y are connected to Node Status Retrieval Allowed If checked the Node status can be shown on a API application and the Dispatcher Profile No Limits If barred is checked no profile can be generated from...

Page 225: ...ile number series e g 100 110 200 210 and so on as profile number This will make it possible to create sub profiles if needed Figure 3 18 Subscriber Profile The main window allows the user to Add Copy...

Page 226: ...o the profile and used by the subscriber setting a reference only valid in the Add Copy function o Description The logical profile name related to the profile function o Home Organization The organiza...

Page 227: ...ions Organizations associated with each other will allow calls between the associated organizations Association must be done mutually in both organizations o Service restrictions Option to restrict th...

Page 228: ...to None no restriction All Subscribers and only Dial in Subscribers If set either to all Subscribers or Dial in Subscribers only groups in the list can be accessed in the organization the profile belo...

Page 229: ...ar Systems A S Denmark TetraFlex Network Management TetraFlex 7 5 Manual 3 210 Figure 3 21 Radio cell restrictions o Subscriber class Definition if subscriber class is mobile controlled or defined in...

Page 230: ...lass programmed If in the profile setup MS controlled is selected it is the MS s programming that decides about which nodes the terminals will try to attach to If defined in the profile the MS will re...

Page 231: ...TetraFlex 7 5 Manual 3 212 Figure 3 24 TEA details o Short No Format Enabling user short number for the profile and definition of short number Figure 3 25 Short number details Example shows that the s...

Page 232: ...controlled mobile programmed priority is in use 01 is the lowest priority and 14 is the highest priority 15 pre emptive can be programmed in the radios and are used for alarms Pre emptive priority mea...

Page 233: ...ls Note that the requested PTT priority from the uplink can be overwritten by the requesting MS s profile and or by the called group s profile via the NM OM Timers Timers are mainly used to restrict u...

Page 234: ...GW Setup PD GW connection node o PD GW1 is the Primary node and PD GW 2 is the redundant node See section 3 3 4 6 13 for Voice GW setup and test DNS IP address Used by Packet Data setup If used the DN...

Page 235: ...I number must always be assigned to a subscriber and the system doesn t allow using the same SSI number more than one time The field will be marked yellow when trying to type in the same SSI number tw...

Page 236: ...automatically shown when the profile number is entered Only existing profile numbers can be used o Organization number Automatically shown when profile number is entered The organization description i...

Page 237: ...nal is assigned an ISSI and user number in the normal manner If not used TSI will display Home Subscriber o TEI If authentication is used the correct TEI for the terminal must be entered It is highly...

Page 238: ...r if not using the unconditional setting 3 3 5 4 2 Group subscriber Additional fields in group subscribers o Group Text If the subscriber is a group subscriber the field will be available for entering...

Page 239: ...Group 3 Disaster management Group 3 is set up with group include on Group 1 and Group 2 Function will be Group 1 PTT is heard in Group 1 Group 2 PTT is heard in Group 2 Group 3 PTT is heard in Group...

Page 240: ...on Generate key this function generates an Authentication key that can be used for authenticate an API client or Dispatcher on the TetraFlex network The generated key must be send from the Dispatcher...

Page 241: ...o Temporary Mobile Enable Disable allowed Temporary enabling disabling of MS from the API client Dispatcher o Permanent Mobile Disable allowed Permanent disabling of MS from the API client Dispatcher...

Page 242: ...nt or a Group Bridge on the TetraFlex network The generated key must be entered and stored in the TetraFlex Client or Group Bridge When Disable option is active the authentication key is not needed fo...

Page 243: ...dial in to Group 1700003 Dial 700000 Damm PABX Answering machine Dial 1700003 Damm group 3 Answering machine Dial 99 Dial In number Now the PABX user can make a PPT group call or a Voice detect group...

Page 244: ...3 3 5 4 6 Emergency subscriber The Emergency Subscriber is used for Transferring a Tetra Call to the Voice Gateway or another Tetra Subscriber responsible for Emergency e g sending it to the public 11...

Page 245: ...ty Key Register The key register must be enabled on the Master node Can be set in NM from the BSC list Subscriber Key Status Shows if the key register is enabled SIM count the numbers of SIM numbers f...

Page 246: ...count numbers of TEI numbers found SSI count numbers of SSI numbers found SSI Security Set update Pressing the Renew all security sets button all security sets will be renewed This allows the update o...

Page 247: ...rk Management TetraFlex 7 5 Manual 3 228 3 3 6 Log Servers The Alarm state Status and IP addresses of the Log Server s that are attached to the system can be shown by clicking the Log Servers icon Log...

Page 248: ...he LogSrv fields you get the Log Server Operations dialog Log Client Start the Log Client Remote Desktop Starts the Remote Desktop Client Explorer Starts Windows Explorer Acknowledge Alarms Acknowledg...

Page 249: ...gister K1 The Security Keys derived from the K file and placed in the key register Security set The distributed key sets Should be updated at regular intervals 3 4 3 Description The key file produced...

Page 250: ...rk as usual except that new terminals cannot be added to the Subscriber register When using encryption Authentication it is recommended to wait adding subscribers until the node containing the Master...

Page 251: ...node containing the Master Subscriber Register is totally lost or an exchange or change of node for some other reason is preferred then all Key Files K can be read in again on the new node using the d...

Page 252: ...e several simultaneous application connections The connection from the application to the system is done with standard IP protocols TCP UDP to the external WAN side of the node and the application can...

Page 253: ...dll will be fully backward compatible which means that older GUI applications can use a newer version of TetraFlexApi dll 3 5 2 TetraFlex Dispatcher Functionality The Dispatcher application is develo...

Page 254: ...to open the Phonebook Voice Calls SDS Position File Transfer DGNA Nodes and the Config views Notice that the dispatcher connection information is provided as well Double click on the Missed Call Unrea...

Page 255: ...Damm Cellular Systems A S Denmark TetraFlex Dispatcher TetraFlex 7 5 Manual 3 236 Figure 3 36 Views 3 5 3 1 Connection Configuration Refer to part 2 section 2 13 for configuration explanation Figure...

Page 256: ...tabs Configuration may also be entered using the configuration icon 3 5 3 2 1 Audio Figure 3 38 Dispatcher Configuration The audio tab allows configuration of the Speaker and Microphone settings for...

Page 257: ...lumes button Gives an overview of which Windows sound devices is active in Windows If a device is adjusted to 0 dB a red alert comes up to indicate that this device cannot be used for audio input or o...

Page 258: ...History Max Age 60 to 518400 min 360days The max numbers of minutes that a call will be showed in the call history database before it will be deleted Call History Max Size 20 to 5000 entries This is t...

Page 259: ...Systems A S Denmark TetraFlex Dispatcher TetraFlex 7 5 Manual 3 240 3 5 3 2 4 Map View Figure 3 40 Map View Google The Map view has the following options for showing geographic maps with Radio GPS pos...

Page 260: ...n information can be added in the client Id and Key fields It is possible to add layers on top of these maps in ESRI shape format Open Street maps Free geographic data It is possible to show e g RSSI...

Page 261: ...o has deregistered or the GPS signal is lost The value can be from 1 to 600 minutes o Position History Max age The time frame that the position history will be shown on map The setting can be from 1 h...

Page 262: ...will be deleted whatever comes first 3 5 3 2 6 SDS Default Request ack If set the SDS will by default be sent with the Request ack flag set Default Request consumed If set the SDS will by default be s...

Page 263: ...ther information 3 5 3 2 8 Updates The Auto updates function will search for newer a Dispatcher version when the Dispatcher is running I will search either on the share on the node where it is connect...

Page 264: ...profiles and SSI belonging to the dispatcher s home organization or associated organizations These can be seen and changed if the Subscriber Register changes allowed flag is set for Application SSI th...

Page 265: ...etraFlex 7 5 Manual 3 246 Figure 3 44 Subscriber register change For more information regarding the Application SSI please the chapter Network Manager Subscriber The Subscriber has now got an new Find...

Page 266: ...tivated from the Dispatcher Tool Bar or from the top bar Views selection From this panel the Dispatcher is able to initiate various types of calls and send Status and Text SDS s The Phone Book contain...

Page 267: ...tcher TetraFlex 7 5 Manual 3 248 Figure 3 46 Phonebook 3 5 4 1 Mobile indicators in the phonebook Indicates a mobile with a group selected Indicates a mobile with a group active but not selected in th...

Page 268: ...ight edge of the dispatcher window To dock use the left or right arrow in the top bar of the phone book and to float use the floating symbol 3 5 4 3 Phone Book Search Figure 3 47 Search dialogue It is...

Page 269: ...3 5 4 4 Direct call When double click on a subscriber in the Phone list you can establish a direct standard group call if a group SSI Individual duplex call if an individual SSI etc to these subscrib...

Page 270: ...0 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Dispatcher TetraFlex 7 5 Manual 3 251 Figure 3 48 Group Call dialogue Then select the function required It is possible to change the Priority of...

Page 271: ...the result and select the desired function to be performed from the call dialog NOTE Selections may be active or grayed out according to the selected subscriber configuration 3 5 4 6 Show Associated...

Page 272: ...Manual 3 253 Figure 3 50 Associated organizations 3 5 4 7 Show favorites Figure 3 51 Favorites In favorites any number reachable form the infrastructure can be entered this includes Tetra SSI s PABX...

Page 273: ...ws the view of either all subscribers or only subscribers currently registered at the system When all subscribers are selected non registered subscribers will be shown as grayed out NOTE Subscribers w...

Page 274: ...e call line has an active PTT button 3 5 4 9 Subscriber always displayed For subscribers frequently used it is possible to transfer the subscriber to the Voice Call window on a permanent basis making...

Page 275: ...on the desired subscribers master PTT icon and all other selections will be reset 3 5 4 12 USB foot switch Master PTT activation can be configured to be executed by means of a USB foot switch DAMM de...

Page 276: ...nd sound card etc use mouse right click on the audio icon Added devices are shown in dark green with a speaker icon inserted The audio device is configured from the Audio tab in the Dispatcher Configu...

Page 277: ...Denmark TetraFlex Dispatcher TetraFlex 7 5 Manual 3 258 Figure 3 56 Fixed Group Indication To select fixed groups right click on the phonebook group and select Voice Call Option Figure 3 57 Voice call...

Page 278: ...radio user discipline needs to be maintained This service also reduces the amount of radio traffic on a network as only essential work related calls are permitted However the frequent need for all com...

Page 279: ...5 6 Call Merge dispatching This service allows the dispatcher to through connect a calling party to any other subscriber Just call the desired subscriber and when connection is established drag the c...

Page 280: ...call icon in the main tool bar will turn red and a red notification line will be added to the Voice call history window Figure 3 62 Missed emergency call Double clicking on the missed call icon with m...

Page 281: ...hide group calls Filter for showing All Incoming Outgoing and Missed calls in the voice call history list Selecting the time period shown in the voice call history list 1 hour to 3 month In the voice...

Page 282: ...p specific for DGNA should be defined in the Subscriber Register 2 Select function Add Group s to DGNA This selects the parent group for the DGNA Figure 3 65 DGNA group Assignment 3 Right click on a s...

Page 283: ...ular Systems A S Denmark TetraFlex Dispatcher TetraFlex 7 5 Manual 3 264 Figure 3 67 DGNA subscriber Assignment Alternatively it is possible to drag and drop the selections to the DGNA group window Fi...

Page 284: ...ssigning subscribers the DGNA group is transferred to the mobile by selecting Assign the parent group to the mobile Figure 3 69 DGNA Assignment 3 5 9 2 De assigning subscribers to DGNA 1 Select group...

Page 285: ...log which is available in the SDS and Phone Book windows The predefined Status SDS s in the list are Organization in depended since they are completely transparent to the infrastructure The predefined...

Page 286: ...The types of SDS reports which are supported are Delivery consumed Report Request The receiving Terminal shall report when the SDS has been received Action accomplished The receiving Terminal has open...

Page 287: ...lls will be indicated in the SDS call window as a red bar containing the standard SDS options Also an alarm tone will be played and can be reset by answering selecting the call Figure 3 77 Emergency S...

Page 288: ...ing The TetraFlex dispatcher offers GPS positioning Positions may be shown as a function of automatic positioning information sent from the terminals or as a manual request from the dispatcher This fu...

Page 289: ...cle and subscriber details Center on map Center the GPS position on the map Position History Shows the Position History window and the historic GPS position on the map as yellow circles Request positi...

Page 290: ...so the dispatcher will pick up the SDS information process and show it as a position on the map Positioning SDS s are filtered out and will not be shown in the dispatcher SDS inbox 3 5 12 3 Overlay fi...

Page 291: ...e use the folder icon When loaded it will be available in the overlay list By Right clicking on the overlay in the menu you get the possibility to Delete them again make them Visible or not Visible an...

Page 292: ...y is removed or in another way comes unavailable without de registering is will still be shown on the map as registered Show history Shows the historical plot of GPS coordinates for the selected radio...

Page 293: ...s can be used for making a coverage map or just to see the RSSI levels of a radio on the map Only history shows only the historical GPS positions Uplink RSSI Shows the RSSI level the actual node measu...

Page 294: ...er TetraFlex 7 5 Manual 3 275 When selecting Send Files you get the file transfer container Here you can either drag and drop the files you want to send from e g the file manger or you can use the fil...

Page 295: ...Denmark TetraFlex Dispatcher TetraFlex 7 5 Manual 3 276 When the receiving dispatcher receives the file s a notice will come in the mail box icon in the process line and the file s will be shown in th...

Page 296: ...twork and the Log Server The TetraFlex network infrastructure consists of TetraFlex Nodes which are connected through a backbone IP net as illustrated in Figure 3 80 Log Servers are passive network el...

Page 297: ...ex Network with Log Server the SQL Server and the Log Server are running on the TetraFlex Log Server machine Figure 3 80 TetraFlex Network with Log Server It is possible to attach one or more TetraFle...

Page 298: ...y is a user interface for the Log server application and is automatically started as a tray application indicated with a small icon on the taskbar when the log server starts By right click on the log...

Page 299: ...tion Queries can be made for a specified time interval as well as Only from Only to and combination of this Set up query and replay Voice data from the database for voice logged group and individual c...

Page 300: ...possible to open the Statistics CDR MS Reg Status and the Settings view Note that the title bar indicates which SQL Server and database the application is connected to 3 7 3 Statistics View The Statis...

Page 301: ...Denmark TetraFlex Log Client TetraFlex 7 5 Manual 3 282 Figure 3 82 Configuration Dialog example Figure 3 83 Export Dialog example 3 7 3 1 Node Shows the Node Alarm as percentage of time Indications...

Page 302: ...ode 3 7 3 2 Radio The Radio tab has 3 sub tabs All tabs has a selection of resolution to 1 minute 10 minutes 1 hour or 1 day All tabs has the selection of table or graphic view 3 7 4 Radio Cell Alarm...

Page 303: ...re Timeslot table Timeslot type Description CCH Control Channel MCCH and SCCH Group Call TS GTCH Timeslots used for group calls Individual Call TS ITCH Timeslots used for individual calls Packet Data...

Page 304: ...3 87 Radio Congestion 3 7 5 Voice GW Voice GW tab has 3 sub tabs 3 7 5 1 Voice GW Alarm Shows alarms as percentage of time Figure 3 88 Voice GW Alarms 3 7 5 2 Voice GW Channels Shows GW channels rela...

Page 305: ...TetraFlex 7 5 Manual 3 286 Figure 3 90 Voice GW Congestion 3 7 6 Packet Data GW Shows GW alarms related to percent of time Figure 3 91 Packet Data GW Alarms 3 7 7 Application GW Application GW has 3...

Page 306: ...etraFlex Log Client TetraFlex 7 5 Manual 3 287 Figure 3 92 Application GW Alarms 3 7 7 2 Application GW registration Shows numbers of application registered Figure 3 93 Application GW registrations 3...

Page 307: ...A S Denmark TetraFlex Log Client TetraFlex 7 5 Manual 3 288 Figure 3 94 Application GW registrations 3 7 8 Terminal GW Terminal GW has 3 sub tabs 3 7 8 1 Terminal GW alarms Shows GW alarms related to...

Page 308: ...Denmark TetraFlex Log Client TetraFlex 7 5 Manual 3 289 3 7 8 2 Terminal GW registrations Shows the Terminal GW Registrations Figure 3 96 Terminal GW Registrations 3 7 8 3 Terminal GW Streams Shows t...

Page 309: ...earch Criterion is entered press Search button to load the Search Results from the SQL Server Figure 3 98 Log Client Call Data Records The Search Result lists all the calls matching the Search Criteri...

Page 310: ...dditional Call Info In the Additional Call Information view the Talking Parties in simplex calls are listed It is also indicated whether the Talking Party has preemptive rights and which node the MS i...

Page 311: ...empt from unknown subscriber rejected BS detected an inconsistency Inconsistency in registration data means that the data we got from an MS now does not match the last transaction with that MS That ca...

Page 312: ...ate Type state and which Node that has received it The list is sorted in SSI number order Figure 3 100 Log Client Latest MS Registrations 3 7 10 2 MS Registration History The MS Registration History t...

Page 313: ...was used for the call NB From log server version 7 52 MS RSSI history data older than 24 hours will be deleted 3 7 11 Status Views The status views windows shows the latest received Status messages of...

Page 314: ...f component Blocked L3 Level 3 Blocking Alarm dropout of component Start up The component is starting up Not Alive The component is not responding BLANK or Not Configured The component is not configur...

Page 315: ...to see the Hardware type numbers of Nodes in total and the repetition time interval which the node uses for sending its status message 3 7 11 3 Subscriber Figure 3 104 Log Client Status Subscriber Re...

Page 316: ...io Status On the Radio Status tab it is possible in real time to see the number of registered Mobile Air encryption AIE status Neighbor cell synchronization main carrier and tetra channel and the acti...

Page 317: ...Cellular Systems A S Denmark TetraFlex Log Client TetraFlex 7 5 Manual 3 298 3 7 11 6 Voice GW On the Voice GW tab the status for the Voice Gateway can be seen including number of active and idle call...

Page 318: ...S Denmark TetraFlex Log Client TetraFlex 7 5 Manual 3 299 3 7 11 7 Packet Data GW Figure 3 108 Log Client Status Packet Data GW The Packet Gateway view shows only the gateway status 3 7 11 8 Applicat...

Page 319: ...eway and license dongle the actual numbers of streams and the max number of streams allowed by the gateway and dongle license 3 7 11 9 Terminal GW Figure 3 110 Log Client Status Application GW The App...

Page 320: ...cifying the IP address and login credentials By pressing the Connect to Database Button the client establishes the connection to the SQL Server and database specified This can be done on the fly The R...

Page 321: ...s is totally done by the log server based on the settings made by the client The maintenance is performed by the LogServer which executes 2 steps An optional backup of the database files to a network...

Page 322: ...l The Maintenance task can be executed each day every week every 2nd week or every 4th week depending on the selected Maintenance interval To enable backup of database put a check mark in the Backup d...

Page 323: ...ed maintenance task To enable or disable cleanup of old database records set or remove the check mark in Cleanup database records after backup and specify the cleanup threshold in the Delete record ol...

Page 324: ...comes available 3 7 13 3 Maintenance History Once the maintenance has finished the result of the maintenance can be found in the Maintenance history Open the Maintenance History dialog to see the list...

Page 325: ...he TetraFlexLogDb database is stored either under the default MySql data path C Program Files MySQL MySQL Server 5 0 data tetraflexlogdb or on systems with more partitions E Tetra Applications LogServ...

Page 326: ...the copy has finished the MySql Server locks the files and you will no longer be able to rename or delete the database files The MySql service has to be stopped to delete or rename a database folder I...

Page 327: ...p restored The LogClient is now connected to the restored database and you can only browse through the old data till you select the active running database named TetraFlexLogDb Note if you have not sa...

Page 328: ...ived information If a node has managed to send status messages prior to the node being configured with the correct node number etc the node may be deleted here and will reappear with the correct setti...

Page 329: ...erver database has default no information about the subscribers and it is only logging information it gets from the incoming data If you want to have information like subscriber description user numbe...

Page 330: ...de User no Subscriber user number Profile The profile the subscriber belongs to and because of the profile must belong to a organization this will also give the organization the subscriber belongs to...

Page 331: ...gistrations log Note Voice Logging For individual calls the following rule applies If either the calling or the called party is on the subscriber list the call is voice logged otherwise not For group...

Page 332: ...e default c tetra active data Subscr txt and either pushing the Create new button this will delete subscriber that already has been added or using the Merge button this will add new subscriber to subs...

Page 333: ...A S Denmark TetraFlex Log Client TetraFlex 7 5 Manual 3 314 Standard setting USERPROFILE Tetra LogClient LogServer name Wav Files The settings can be saved by using the Save Sound Settings button and...

Page 334: ...1 4 Damm Cellular Systems A S Denmark TetraFlex Log Client TetraFlex 7 5 Manual 3 315 3 7 13 9 LogServer Licens License dongle information shows the license dongle settings for the Log Server Figure...

Page 335: ...ase see the chapter 2 10 3 for setting the parameters Figure 3 126 LogServer config Log Server Settings may be overruled by the dongle configuration Logging selection may be set equal or less than the...

Page 336: ...tra SwMI or a analog system It is also possible to send and receive SDS group messages between TetraFlex and other Tetra systems The following diagram shows an overview of the DAMM TetraFlex Group Bri...

Page 337: ...and bridges are controlled by a license dongle connected to a USB port on the computer that is running the Group Bridge The Group Bridge uses the Group SSI GSSI to determine if it should route a call...

Page 338: ...ed to a PC and installed in any folder on the PC There is 2 version of the installation file GroupBridge exe for Windows 32 bit and GroupBridge64 exe for Windows 64 bit A valid dongle with Group Bridg...

Page 339: ...e service by selecting Stop service The service can then again be started by selecting Start service The Group Bridge GUI can be closed without stopping the running service either by selecting Exit or...

Page 340: ...box can be used to enable and disable this bridge When disabled the hole row is grayed The next step is to setup Terminal Gateway connection to both TetraFlex system 1 on node 1 and TetraFlex system...

Page 341: ...dge user number This is the user number that must be defined in the subscriber register for each Terminal Gateway connection SSI number can not be used and the user number must be unique Group User Nu...

Page 342: ...version has support for DVI 100 Address The IP address for the Tetra Radio Device Default factory setting from Piciorgros DVI 100 is 192 168 0 199 If necessary this has to be changed in DVI 100 to ma...

Page 343: ...v Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Group Bridge TetraFlex 7 5 Manual 3 324 Group talker ID must be set to SSI for MS compatibility on the profile used by DVI 100 to use S...

Page 344: ...either from Open GUI button or by starting a browser and type the IP address of the DVI 100 you get a login dialog First time you set up the unit you have to use the factory default User name and Pas...

Page 345: ...he next setting is the DVI 100 mode and the port number Set this to Server and port 3141 The port address can be changed is needed but then the port setting in Group Bridge most also be changed to mat...

Page 346: ...the tetra parameters must be set to match the setting in the tetra network which the DVI 100 must connect to The tetra mode must be TMO and TSI parameters ISSI MCC MNC must match the tetra network to...

Page 347: ...ystems A S Denmark TetraFlex Group Bridge TetraFlex 7 5 Manual 3 328 The last thing necessary to set is Group SSI It is possible to use one group together with the Group Bridge The group SSI must be u...

Page 348: ...ist any of the installed Windows recording devices can be selected This is the analog audio input for this connection Serial no This is the serial number for the OnTrak USB I O interface ADU200 or ADU...

Page 349: ...erent TetraFlex networks Group x Group y Node w Terminal Gateway TetraFlex Network x TetraFlex Netork y Group Bridge IP IP Node w Terminal Gateway Example 2 Group call between a TetraFlex network and...

Page 350: ...Tetra Networks Group Bridge IP IP Tetra Radio Device Node w Terminal Gateway Example 4 Combination of connecting different Tetra and Analog networks Tetra MS Group x Tetra MS Group y TetraFlex Network...

Page 351: ...5 Manual 3 332 Example 5 Group Bridge with more Groups Group A Group C TetraFlex Network x Other Tetra Networks 5 IP Tetra Radio Device Node w Terminal Gateway Group D 6 7 Tetra Radio Device Tetra Ra...

Page 352: ...Digital I O Ontrak ADU200 www ontrak net Analog Radio Device Any radio with audio PTT and Squels I O TetraFlex Group Bridge Application Group Bridge Client Dongle TetraFlex Terminal Gateway TetraFlex...

Page 353: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Group Bridge TetraFlex 7 5 Manual 4 334 PART 4 Technical References...

Page 354: ...the RX antennas or alternatively ground mounted at the BS rack The TMD412 in addition contains a Duplex Filter which optionally can combine the TX and one RX to run on same antenna Whenever possible i...

Page 355: ...BS to the top of the mast is the same for both cases 4 1 2 1 TMA412 TMD412 A block diagram of the TMD412 is shown below The TMA412 is identical except for the omitted Duplexer RX A TEST RX B GPS1 GPS2...

Page 356: ...tenna The BS uses two receiver antennas for its dual RX diversity implementation The TMA is provided with a dual tower mounted amplifier with input filters amplifiers and test circuits for measurement...

Page 357: ...maximum allowed length of different possible cable types Cable with 8dB loss 450MHz 850MHz RG223 U 28m 19m RG214 U 50m 35m 1 4 inch RFS CF14 50 85m 60m 3 8 inch RFS LC38F 50 105m 75m 1 2 inch RFS LCF...

Page 358: ...e connectors on the antenna and BS Cables and connectors between antenna and TMD412 BS41x shall be resistance to water ingress and migration 4 1 3 GPS antenna Each Base Station Controller includes a G...

Page 359: ...products with a level typically 15dB below the interfering signal The BS41x Base Station is provided with double circulators in the TX output to make sure that IM3 products close in frequency will be...

Page 360: ...critical thing to remember about inter modulation is that it is very difficult to predict accurately For antenna constructions two factors heavily degrade the performance Over years connectors etc sta...

Page 361: ...Damm Cellular Systems A S Denmark TetraFlex Antenna System for BS41x TetraFlex 7 5 Manual 4 342 Check the RSSI again The difference in RSSI directly indicates the reduction in sensitivity due to dist...

Page 362: ...her radio equipment installed in the same mast Two different methods exist in order to combine several transmitters to a single antenna o Cavity Combiner combining with filters o Hybrid Combiner combi...

Page 363: ...les connects the units together The schematics of the cavity combining system are shown below 4 2 2 1 Circulator The TX output signals come from the TR41x to the TC411 in cables attached to the Casset...

Page 364: ...first port A diode detector connected to the resistor makes it possible to monitor the size of the reverse signal Some of the signal will be reflected at the high power resistor and follow the red li...

Page 365: ...4 way lambda junction which transforms the short circuit of the cavity at out of band frequencies to open circuit at the junction point 4 2 2 3 Junction cables The TC411 combiner module can either be...

Page 366: ...rent outputs are forwarded to the BSC412 Base Station Controller which can display the actual output and reflected power at the TX antenna connector The following OM commands can be used to check the...

Page 367: ...be accessed from the BSC411 The center frequency of the cavity can be fine adjusted with the 13 command in the TCC411 This is normally not needed but could be done if e g the BS is placed at a high al...

Page 368: ...tion normally caused of the RX feeder loss The TMA can compensate for up to 8dB feeder loss with no change in RX sensitivity allowing the use of thin feeders with a considerably saving in feeder expen...

Page 369: ...e arrestor After passing the DC insertion circuit the RX signal passes a directional coupler which can be used to provide a test input signal through the TNC connector on the AI411 front plate Afterwa...

Page 370: ...ollows the similar settings in the RM Afterwards follows a variable attenuator adjustable through the AI411 front hole marked IN This attenuator is used to compensate for output power selection of the...

Page 371: ...ning on the DSP and controller The standard TETRA version also support analogue PM modulation for testing purposes to allow complete testing of a site with analogue test equipment 4 4 2 Receiver The r...

Page 372: ...ed to the 12 8MHz reference The signal is amplifier to about 13dBm and brought in another cable to the RX Front End where it is split into two 7dBm injection signals for the two 2nd mixers 4 4 3 Trans...

Page 373: ...with good margin Hardware and software support is provided for open loop operation with different modulation types to allow easy adjustment and test of the transmitter A dual RMS power detector is pr...

Page 374: ...t of the DSP and goes to the BSC via the MC and the HDLC bus 4 4 6 Micro Controller The MC is handling the over all administration of the TR412 The MC is provided with 1024kByte segmented FLASH memory...

Page 375: ...of an RX Tower Mounted Amplifier removes the influence of the RX feeders effectively improving the link balance with the loss of the TX feeder which could be 2 dB for a typical system The use of a du...

Page 376: ...ons can also be seen from the result of the combining process If two equal signals are added the two input signals are added effectively giving the double input voltage equal to an increase in input s...

Page 377: ...asured BER Bit Error Rate for a standard TCH7 2 traffic channel with the TU50 fading profile The correlation factor between the two signals is 0 2 4 5 4 MER versus input signal SCH F 0 1 2 3 4 5 6 7 8...

Page 378: ...etraFlex 7 5 Manual 4 359 These curves show the measured MER Message Error Rate for a standard SCH F Signaling Channel Full with the TU50 fading profile The correlation factor between the two signals...

Page 379: ...DC for the TX PA DC DC converter providing 14V DC for all other BS parts Microprocessor for charging control monitoring and alarm generation The following number of PS411 is needed depending on the nu...

Page 380: ...al units e g Ethernet switches E1 modems etc 4 6 3 14V and 26V DC DC converters The PS411 Power Supply contains two independent DC DC converters providing 14V and 26V respectively from the 48V DC inpu...

Page 381: ...al UART interface O M communication is possible on both interfaces The PS411 is provided with internal resident settings to hold the charging configurations etc When used in a BS41x these settings wil...

Page 382: ...pacity by stopping the rectifier with the command 21 Check the response from command R 10 If the battery is defect the BSC will be shut down by stopping the rectifier so the battery can be checked fir...

Page 383: ...47 0V drops 2 5V see fig 1 Fig 2 Show a battery in bad conditions probably a defect cell that has to be replaced 3 If the battery voltage drops more then the battery does not have the full capacity an...

Page 384: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Battery test SB421 TetraFlex 7 5 Manual 4 365 Fig 2 Example of a defect battery...

Page 385: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Battery test SB421 TetraFlex 7 5 Manual 4 366...

Page 386: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Hardware Unit References TetraFlex 7 5 Manual 5 367 Part 5 Hardware Units...

Page 387: ...306 REF CAS417 PS Cassette D104352 REF CON411 Connection Box D104803 REF External Battery kit for BS41x D104260 REF PS411 Power Supply with rectifier D104251 REF RMD411 Dual 8 way div D104431 REF RMD4...

Page 388: ...purchased from DAMM If this recommendation is not used it is mandatory to procure hardware with similar of better characteristic to ensure a problem free operation of the system DAMM item No Descripti...

Page 389: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Recommended hardware TetraFlex 7 5 Manual 5 370 5 2 1 Sealed Coaxial cable 880014...

Page 390: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Recommended hardware TetraFlex 7 5 Manual 5 371...

Page 391: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Recommended hardware TetraFlex 7 5 Manual 5 372 5 2 2 Ethernet cable 105091 105092...

Page 392: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Recommended hardware TetraFlex 7 5 Manual 5 373...

Page 393: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Recommended hardware TetraFlex 7 5 Manual 5 374...

Page 394: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Recommended hardware TetraFlex 7 5 Manual 5 375...

Page 395: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Recommended hardware TetraFlex 7 5 Manual 5 376 5 2 3 Power cable 105093 105094...

Page 396: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Recommended hardware TetraFlex 7 5 Manual 5 377 5 2 4 SB421 internal battery 7980001...

Page 397: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Recommended hardware TetraFlex 7 5 Manual 5 378...

Page 398: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex Recommended hardware TetraFlex 7 5 Manual 5 379 5 2 5 GPS antenna 8230001...

Page 399: ...oller F1 794006 Fuse 5x20 6 3A F IR 1500A PS421 Power Supply F101 794025 Fuse 5x20 3 15A T IR 100A Router cass DC booster F101 541 2975 SB421 Inter connection board F133A F113A 794026 Fuse 5x20 10A T...

Page 400: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex List of Figures TetraFlex 7 5 Manual ccclxxxi Part 6 List of Figures Index...

Page 401: ...URE 1 22 BS41X LED S 1 25 FIGURE 1 23 POWER SELECTION 1 26 FIGURE 1 24 POWER TERMINALS 1 26 FIGURE 1 25 TEMPERATURE SENSOR CONNECTION 1 27 FIGURE 1 26 MAINS CONNECTION BLOCK 1 28 FIGURE 1 27 CONNECTIO...

Page 402: ...2 154 FIGURE 2 45 VNC MY DEVICE 2 154 FIGURE 2 46 VNC CF CARD DIRECTORY 2 155 FIGURE 2 47 FILE TRANSFER 2 155 FIGURE 2 48 TR SETUP AND SYNC 2 156 FIGURE 2 49 BACKBONE NETWORK PRINCIPLE 2 158 FIGURE 2...

Page 403: ...3 44 SUBSCRIBER REGISTER CHANGE 3 246 FIGURE 3 45 SUBSCRIBER FIND FILTER 3 246 FIGURE 3 46 PHONEBOOK 3 248 FIGURE 3 47 SEARCH DIALOGUE 3 249 FIGURE 3 48 GROUP CALL DIALOGUE 3 251 FIGURE 3 49 INDIVIDU...

Page 404: ...T LATEST MS REGISTRATIONS 3 293 FIGURE 3 101 LOG CLIENT MS REGISTRATION HISTORY 3 293 FIGURE 3 102 LOG CLIENT MS RSSI HISTORY 3 294 FIGURE 3 103 LOG CLIENT STATUS VIEW 3 295 FIGURE 3 104 LOG CLIENT ST...

Page 405: ...Doc No Rev Date 1 00 2013 1 4 Damm Cellular Systems A S Denmark TetraFlex List of Figures TetraFlex 7 5 Manual ccclxxxvi...

Page 406: ...2 BSC412 2 112 BSC421 2 112 C CAD 18 3 259 3 260 call dialog 3 252 3 255 Call Dispatching 3 260 CDR 18 2 102 3 277 3 280 3 281 3 290 3 313 Cell ID 18 CF 18 1 2 1 3 1 5 1 17 2 49 2 51 2 59 2 62 2 69 2...

Page 407: ...erver 2 38 2 39 2 45 2 49 2 51 2 55 2 56 2 101 2 102 2 106 2 111 3 193 3 277 3 278 3 303 3 304 3 315 3 316 M Map 3 183 3 188 3 269 Master PTT 3 256 MCC 18 19 3 190 3 218 MCCH 18 3 194 3 214 3 284 Merg...

Page 408: ...3 226 3 227 3 230 template 3 271 TetraFlexApi dll 2 98 3 233 3 234 TetraOM 19 1 3 1 11 2 39 2 41 2 56 2 57 2 65 2 68 2 74 2 75 2 79 2 85 2 113 2 114 2 115 2 119 2 120 2 129 2 131 2 132 2 133 2 137 2...

Reviews: