Damm Cellular Systems A/S, Denmark

 

BS422 Installation and Setup guideline 

BS422

 Installation guide-

 

Specifications subject to change without notice

5

 

1.2.4  BS422 main components 

Filter cover and filters removed. BS viewed from the filter (back) side 

Figure 1-1:

 

BS422 main components 

The HDMI monitor connector together with the USB connector allows a connection of a 
standard monitor and mouse/keyboard connection 

If monitor, keyboard and mouse are connected, the Windows 10 operation system in the 
BS422 can be accessed directly for configuration or faultfinding purposes 

To access the connectors, remove the filter cover 

To access the CF card also remove the filter mounting plate 
The connectors need not to be unscrewed, just carefully lift the filter base plate slightly and 
the CF card can be removed / inserted 

Summary of Contents for BS422

Page 1: ...s A S This document is subject to copyright and shall not be published or reproduced in whole or in part without the written permission of Damm Cellular Systems A S 2010 Damm Cellular Systems A S All rights reserved Møllegade 68 DK 6400 Sønderborg Denmark Phone 45 74 42 35 00 Fax 45 74 42 30 31 E Mail dcs damm dk http www damm dk ...

Page 2: ...this URL for updated information before attempting to install or correct errors NOTE Chapters marked with a indicate areas where special care must be taken to avoid personal injury or damage to the equipment Before starting installation and configuration please read the entire manual carefully NOTE It is the responsibility of the system owner operator to ensure that only authorized service persons...

Page 3: ...ada le présent émetteur radio peut fonctionner avec une antenne d un type et d un gain maximal ou inférieur approuvé pour l émetteur par Industrie Canada Dans le but de réduire les risques de brouillage radioélectrique à l intention des autres utilisateurs il faut choisir le type d antenne et son gain de sorte que la puissance isotrope rayonnée équivalente p i r e ne dépasse pas l intensité nécess...

Page 4: ...will not extend the maximum range of calculated output power and intermodulation according to the DAMM products sheets Any BS type determines how many TR modules can be installed and the whole BS design has taken the Tetra specification on the subject matters into consideration This is e g reflected in all DAMM EU certificates grants and test reports of which you can find on our web page Please no...

Page 5: ...ing TetraFlex system release notes 4 TetraFlex update to x x pdf Missing Update guideline for ver 7 x to x x 5 TetraFlex x x BS422 redundant setup pdf Missing Redundancy SW setup guideline for BS422 6 TetraFlex v xx User manual Missing These documents are a part of the TetraFlex release and placed in the C tetra Active Doc directory All documents can be found on www damm dk extranet TETRAFLEX MANU...

Page 6: ...ion of the BS422 2 1 2 BS422 Installation 4 1 2 1 Environmental climatic requirements 4 1 2 2 Placement 4 1 2 3 Grounding 4 1 2 4 BS422 main components 5 1 2 5 Attaching RX TX antennas 6 Single BS422 installation recommendation 6 Dual BS422 installation recommendation 6 1 2 6 Power connection to BS422 7 System Connector 8 1 2 7 Ethernet Connection 10 1 2 8 RJ45 Ethernet Connection terminals 11 2 1...

Page 7: ...lease Date Main Cause of change Author Approved 8 xx 1 00 01 11 2017 Initial release JR Record of Changes of Documents since last Manual Version Number Man ver Sec Page Cause of change Date Initial IMPORTANT DAMM will execute great effort to maintain and update this manual so it will always be up to date regarding information and readability To do this DAMM needs to get feedback from you So if you...

Page 8: ...t Mode over IP DB Data Base DCK Derived Cipher Key DGNA Dynamic Group Number Assignment Dongle A USB dongle programmed by DAMM to be inserted in the node and or application PC The dongle controls which functions and applications can be executed Dongle Date Limit When this date is exceeded the dongle will not allow execution of DAMM software packages DSA Dynamic Subscriber Assignment DSP Digital Sp...

Page 9: ...nodes SLA Service Level Agreement earlier called Service and Maintenance Agreement SMA SNMP Simple Network Management Protocol Software package A package containing all functions and applications available on the release date SSI Short Subscriber Identity Subscriber register Register where the variable data regarding subscribers and profiles are stored TBD To Be Determined TCP Transmission Control...

Page 10: ... No Rev Date 1 11 2020 03 06 Damm Cellular Systems A S Denmark BS422 Installation and Setup guideline BS422 Installation guide Specifications subject to change without notice 1 PART 1 Hardware Installation ...

Page 11: ...echnology basestation that is based on a Software Defined Radio which enables it to operate several different radio technologies TETRA TEDS DMR Tier 3 Analog PMR Each BS422 can operate up to four different carriers simultaneously independent of the selected radio technology inside a defined band The different carriers may operate in different bandwidths depending of the selected technology 25kHz T...

Page 12: ... needed All features for a functional trunked radio system is build into the BS422 The basestation is designed for direct outdoor mounting Block diagram Soft Transciver Controller LAN WAN GPS reveiver ADC DAC Filter Rx Tx RX TX RX USB Display port Dimensions 360 mm 245 mm 190 mm Weight 9 Kg approximately Power supply External 48Vdc source 100 W approximately full output power Cooling Natural conve...

Page 13: ...efined temperature range from 40 C to 55 C ambient air temperature is optional upon request The Base Station encapsulation complies with IP65 1 2 2 Placement The recommended placement of the Base Station is as close to the antennas as possible to reduce cable loss The placement of the Base Station shall be such that it is securely fastened to a mast or building that is able to carry the weight of ...

Page 14: ... monitor connector together with the USB connector allows a connection of a standard monitor and mouse keyboard connection If monitor keyboard and mouse are connected the Windows 10 operation system in the BS422 can be accessed directly for configuration or faultfinding purposes To access the connectors remove the filter cover To access the CF card also remove the filter mounting plate The connect...

Page 15: ...d one for GPS TX RX A GPS RX B Figure 1 2 Single BS422 NOTE The BS422 will function with only Tx Rx A and without GPS antenna with the following limitations Timing via GPS will not be available BS422 runs on internal oscillator Not recommended and there will be no Diversity when only using one Rx antenna Dual BS422 installation recommendation o Cables to the 2 x BS422 two for TX RX two for GPS and...

Page 16: ... carefully LAN WAN or LAN PPS Figure 1 4 Power connection The BS422 is operated at 48V nominal DC SELV Safety Extra Low Voltage DO NOT UNDER ANY CIRCUMSTANCES USE A POWER SUPPLY THAT HAS THE MINUS CONNECTED TO POWER SUPPLY CHASSIS The cables used for power supply must be equal to or more than 3 x 1 5mm2 Connect the three wires in the power connection cable according to the color markings inside th...

Page 17: ...s subject to change without notice 8 System Connector There is two type of System Connetors 1 System Connector with LAN and WAN 30528001 2 System Connector with LAN and PPS 30528002 Use a LSA tool for the Ethernet connection a small flat screedriwer for the power connector and torx screwdriver for the fastner clamps Figure 1 5 System Connector ...

Page 18: ...Cellular Systems A S Denmark BS422 Installation and Setup guideline BS422 Installation guide Specifications subject to change without notice 9 Cable connection for LAN WAN 30528001 NOTE Cable used must be 0 4mm2 to 0 6mm2 24AWG solid cores ...

Page 19: ...t type DC connection for timing PPS The purpose of the connections is o To establish connection for control of the base station o To establish connection to other BS422 and for timing and synchronization 1 sec Pulse PPS The Ethernet connections are limited to SELV Safety Extra Low Voltage connections The PPS DC timing connection can be connected to another BS422 for timing Arresting units are an i...

Page 20: ...0 03 06 Damm Cellular Systems A S Denmark BS422 Installation and Setup guideline BS422 Installation guide Specifications subject to change without notice 11 1 2 8 RJ45 Ethernet Connection terminals RJ45 connection for WAN LAN ...

Page 21: ...ev Date 1 11 2020 03 06 Damm Cellular Systems A S Denmark BS422 Installation and Setup guideline BS422 Installation guide Specifications subject to change without notice 12 Cable connection for LAN PPS 30528002 ...

Page 22: ...Doc No Rev Date 1 11 2020 03 06 Damm Cellular Systems A S Denmark BS422 Installation and Setup guideline BS422 Installation guide Specifications subject to change without notice 13 ...

Page 23: ...Doc No Rev Date 1 11 2020 03 06 Damm Cellular Systems A S Denmark BS422 Installation and Setup guideline BS422 Installation guide Specifications subject to change without notice 14 PART 2 Configuration ...

Page 24: ...etraflex please change for security reasons Login password xxxxx please change for security reasons LAN IP 172 16 1 10 WAN IP auto DHCP Node No 1 MCC 238 MNC 16024 Mode and TR Physical freq Predefined from ordering 2 1 1 Set up of LAN and WAN IP address Open Network and Sharing Center Windows settings PS The WAN and LAN connections will only showup if there is an active connection at the other end...

Page 25: ... Application GW status S16 Terminal GW status S20 Subscriber registers S20 SAVE Save actual register to text file S20 READ Load data from text file S21 Subscriber profile S22 SSI Register Status R S65 repeating Multicast Unicast addresses S71 General Node configuration R S99 TS repeating Shows all timeslots TR422 Transceiver Network connection in OM BSC LAN IP and port 42022 00 SW Version 01 Displ...

Page 26: ...71 TXREFLWAR 08 TX ant reflected L1 Non Blocking Alarm 10 RX PLL unlocked Blocking Alarm Hardware fault 11 RX LO1 injection low Non Blocking Alarm Hardware fault 16 36 864MHz PLL unlocked Blocking Alarm Hardware fault 18 L3 Frequency Setup Non Blocking Alarm 19 DSP watchdog Blocking Alarm 20 DSP Time Sync Non Blocking Alarm 21 BSC Message Link Blocking Alarm No Link to BSC 22 BSC1 Message Link Non...