Xtium2-CXP PX8 User's Manual
CamExpert Quick Start
•
53
Basic Timing Category
The Basic Timing category groups parameters such as camera type, the active image size, and
other settings related to basic timing.
Parameter Descriptions
The following table describes the CamExpert Basic Timing category of Sapera LT parameters.
Acquisition server notes, if applicable, indicate if parameter availablility or supported values are
dependent on the selected frame grabber acquisition server and acquisition device.
Display Name
Parameter
Description
Notes
Camera Type
Video source image type. Possible
values are area scan or line scan.
Not shown for Bayer
servers (areascan only).
Color Type
Sets the color format of the input
source.
Not shown for RGB
servers.
Monochrome servers
support:
Monochrome
Bayer mosaic
Pixel Depth
Pixel depth (bits per pixel) of the input
source.
Not shown for RGB
servers.
Monochrome servers
support:
8, 10, 12, 14 or 16 bit
Data Lanes
Number of data lanes output by the
camera.
Horizontal Active (in
Pixels)
Sets the horizontal camera resolution
in pixels. This corresponds to the
visible part of the image from the
camera.
Valid range is:
min = 32 pixel
max = 65536 pixel
step = 32 pixel
Note: minimum is per lane
Vertical Active (in Lines)
Sets the vertical camera resolution in
lines per frame. This corresponds to
the visible part of the image from the
camera. Valid range is 1-16777215.
Not shown for linescan
cameras.
Bit Transfer Rate
Sets the transfer rate between the
camera and the frame grabber.
PoCXP
Enables 24V output on the lanes if
PoCXP is supported by the camera’s
connected lane.
PoCXP Status
Shows the current status of the
PoCXP. If at least one lane is powering
camera with PoCXP, it will indicate
‘Active’.
This is a read-only status.