2.8 Timing
L IN E R E A D O U T P E R IO D
N S T RO B E s
T R A N S FE R
P E R IO D
IN T EG R AT IO N P E R IO D
A B C
N
1 0 0 n s M IN
D ata valid o n
e d ge
risin g
IN T E G R AT IO N
IN T E G R AT IO N
P IX E L S R E SE T
E X S Y N C
LVA L
S T R O B E
P R IN
D ATA
O S 1 -O S n
N o te s
O v erc lo c ked p ix els
1
1
2
2
E X S Y N C to LVA L in S T RO B E s : 6 0± 1
LVA L to n e xt EX S Y N C in S T RO B E s , m in .: 0
2.9 Detailed Timing
h LVA L
p ix e l 2
Param.
Description
Units
Min.
Typ.
Max.
T
hLVAL
LVAL
hold
ns
7
T
sLVAL
LVAL
setup ns
33
T
hDATA
Data
hold
ns
15
T
sDATA
Data setup
ns
25