Linea2 5GigE Series Camera
Operational Reference
•
97
Event Control Feature Descriptions
Display Name
Feature & Values
Description
Standard
& View
Timestamp Latch Cmd
timestampControlLatch
Latch the current timestamp internal counter value in the
timestampValue feature.
Expert
DFNC
Timestamp Value
timestampValue
Returns the 64-bit value of the timestamp, which is the
internal Clock timer or the PTP clock timer, depending on
the Timestamp Source selection.. (RO)
Expert
DFNC
TimeStamp Source
timestampSource
Specifies the source used as the incrementing signal for the
Timestamp register.
Expert
DFNC
Internal Clock
InternalClock The timestamp source is generated by the camera internal
clock. Refer to timestampTickFrequency feature for the time
base.
IEEE1588
IEEE1588 The Timestamp source is controlled by the network
IEEE1588 protocol. This source is automatically selected
when PTP mode is enabled.
Timestamp Tick
Frequency (in Hz)
timestampTickFrequency
Indicates the number of timestamp ticks (or increments)
during 1 second (frequency in Hz). This feature changes
depending on the Timestamp Source. (RO)
Expert
DFNC
Timestamp Latch Source
timestampLatchSource
Specifies the internal event or signal that will latch the
Timestamp counter into the Timestamp buffer.
Expert
DFNC
Frame Start
FrameStart
The timestamp is latched on frame start.
Timestamp Reset Source
timestampResetSource
Specifies the internal signal or physical input line to use as
the timestamp reset source.
Expert
DFNC
None
None No timestamp reset source is specified. Note that the
Timestamp reset command can still reset the counter.
Line 1
Line1 Use input line 1 as the timestamp reset source.
Line 2
Line2 Use input line 2 as the timestamp reset source.
Action 2
Action2 Select the GigEVision Action Command 2 as the timestamp
reset source. This is a broadcast command that multiple
devices can respond to simultaneously.
Timestamp Reset Line
Activation
timestampResetLineActivation
Specifies the activation mode to reset the timestamp
counter on the selected line of the TimestampResetSource
feature.
Beginner
DFNC
Falling Edge
FallingEdge Reset the timestamp counter on the falling edge of the
source signal.
Rising Edge
RisingEdge Reset the timestamp counter on the rising edge of the
source signal.
Any Edge
AnyEdge Reset the timestamp counter on the falling or rising edge of
the source signal.
Timestamp Reset Cmd
timestampControlReset
Resets the timestamp counter to 0. This Feature resets both
the internal Clock timer and the PTP clock timer. Note that
the PTP Mode must be disabled first to reset the PTP clock
timer. (WO)
Expert
DFNC