52
Operational Reference
Genie HM-HC Series-GigE Vision Camera
Reset Mode
Exposure starts immediately after a valid trigger. There is no jitter on the start of exposure.
Exposure time is programmable or controlled by the trigger pulse width.
Minimum exposure is 10µs – maximum is 4 seconds, with steps of 1µs.
Sensor readout must complete before the next exposure can start. That is, exposure and readout are sequential.
Therefore, the maximum frame rate is lower than for Synchronous mode.
Any external trigger received before the previous exposure/read out sequence is complete is ignored. An
application can elect to receive messages about ignored triggers. See
"
Events
" on page 71
.
Reset Mode Timing example for Genie
Synchronization Mode via Sapera LT or GigE Vision Compliant
Applications
Sapera
Genie Sapera parameters for Synchronization Mode:
ExposureAlignment
= {Synchronous = 0, Reset = 1}
In CamExpert, these parameters are available under the “Sensor” tab in the “Exposure Control”
dialog box.
See "Accessing Features with + LT
" on page 76
.
XML features for Synchronization Mode:
ExposureAlignment
= {Synchronous = 0, Reset = 1}