18
•
Quick Start Guide
Calibir 640 GigE IR Camera User's Manual
Quick Start Guide
The quick start quide describes common operations such as how to connect Calibir Series cameras,
updating the camera firmware and performing manual fixed pattern noise (FPN) correction.
Connecting the Calibir 640 GigE Vision Camera
Connecting a Calibir to a network system is similar whether using the Teledyne DALSA Sapera LT
package or a third party GigE Vision development package. The computer requires an unused
Ethernet Gigabit network interface (NIC).
The Calibir 640 GigE camera can be powered through the Samtec connector or by Power-over-
Ethernet (PoE), if available, through the RJ-45 connector.
Power Specifications
Before connecting power to the camera, test all power supplies. Power supplies must meet the
following requirements:
Table 4: Calibir 640 GigE Power Specifications
Feature
Specification
DC Voltage
12V/24V (minimum 9V, maximum 57V)
Watts
3.7W
(peak consumption)
Steps For Camera Startup
•
Apply power to the camera.
•
Connect Calibir to the host computer GigE network adapter or to the Ethernet switch via a
CAT5e or CAT6 Ethernet cable.
•
Once communication with the host computer is started the automatic IP configuration sequence
will assign an LLA IP address as described in section Calibir IP Configuration Sequence, or a
DHCP IP address if a DHCP server is present on your network.
•
Check the status LED which will be initially red then switch to flashing blue while waiting for IP
configuration. See LED Indicators for Calibir LED display descriptions.
•
The factory defaults for Calibir is Persistent IP disabled and DHCP enabled with LLA always
enabled as per the GigE Vision specification.
Note: cable should not be less than 1 meter (3 feet) long or more than 100 meters (328