Nano Series GigE Vision Camera
Genie Nano Specifications
•
11
Genie Nano Specifications
The Nano common specifications listed first are followed by model specific tables of functional
features and timing details.
Common Specifications
Camera Controls
Synchronization Modes
Free running, External triggered, Software trigger through Ethernet, Precision Time
Protocol (PTP)
Exposure Control
Internal – Programmable via the camera API
External (Global Shutter models) – based on Trigger Width
Exposure Time Maximum
16 sec (Global Shutter models)
0.5 sec (Rolling Shutter model – C4900)
Programmable in increments of 1µs
minimum (in µs) is model specific
Pulse controlled via Trigger pulse width (Global Shutter models).
Opto-isolated, 2.4V to 24V typical, 16mA min.
Debounce range from 0 up to 255 µs
Trigger Delay from 0 to 2,000,000 µs
Output opto-isolated:
Aligned to the start of exposure with a programmable delay, duration and polarity
(using “start of exposure on output line source” feature)
Features
Image Buffer
(VGA to 5M models)
(8.9M to 18M models)
(NanoXL models)
Refer to
transferQueueMemorySize feature
90 MB total on-board memory for
and
200 MB total
500 MB total
4 kB flash memory for OEM usage (deviceUserBuffer)
Flash memory
32 MB flash memory implemented
Gain
In Sensor gain (model dependent) and Digital gain up to 4x
Auto-Brightness
Yes , with Auto-Exposure and AGC (Sensor Gain or FPGA Gain)
Note1: Sensor Gain AGC only with Sony sensors
Note2: Not applicable to model C4900 (rolling shutter sensor)
Color model output
Color cameras support Bayer output or RGB output firmware.
Binning (monochrome models)
Support for both Horizontal and Vertical Binning: 1x, 2x, and 4x in FPGA
Models M640, M800, M1280, M1930, M2590, M4040, M4060 have in-sensor binning
LUT
Programmable LUT (Look-up-table) up to 12-Bit (model dependent)
Defective Pixel Replacement
Available on some models — up to 1024 entries (2048 for NanoXL)
Automatic White Balance
Available on Color models
Counter and Timer
1 Counter, and 1 Timer. User programmable, acquisition independent, with event
generation, and can control Output I/O pins
Timestamp
Timer to Timestamp images and events (1μs tics using Internal Clock, 8 nanosecond
tics when using IEEE1588 ( PTP: Precise time Protocol)
Metadata
Metadata Output at the end of the Images (also known as GenICam Chunk Data)
Cycling Mode
Automatic cycling between 64 camera setups
Summary of Contents for C1240
Page 215: ...Nano Series GigE Vision Camera Operational Reference 205 ...
Page 275: ...Nano Series GigE Vision Camera Technical Specifications 265 Models M C4090 M C5100 ...
Page 276: ...266 Technical Specifications Nano Series GigE Vision Camera Models M C700 M C1450 ...
Page 277: ...Nano Series GigE Vision Camera Technical Specifications 267 Model M C1950 ...
Page 278: ...268 Technical Specifications Nano Series GigE Vision Camera Model C4900 ...
Page 297: ...Nano Series GigE Vision Camera Additional Reference Information 287 ...
Page 299: ...Nano Series GigE Vision Camera Additional Reference Information 289 ...