20
IPS 10 000 – Firmware Versions 10.7.X| REV. 1.0.0 | © 2021 Dallmeier
6.1.2
Display
The disk status messages are displayed also on the display at the front of the appliance:
Fig. 6-2
HDD is active and OK
HDD is defective
HDD is not active and OK (RAID spare HDD)
HDD is in recovery process (RAID)
HDD is not mounted
▶
Check the status of the hard disk drives.
▶
Identify the defective hard disk drive.
6.2
prOCeDUre
The integrated RAID technology allows continuous recording when a hard disk drive fails. The defective
hard disk drive can be replaced during operation (hot-swap).
Proceed as described below, to ensure the highest possible data security:
Note that
•
new HDDs must be tested and released for mounting by Dallmeier (HDD
white list on www.dallmeier.com).
•
new HDDs may not be formatted or partitioned.
•
HDDs from other devices may not be used.
•
the number of sectors is decisive for the capacity of a HDD, not the usually
specified gross capacity (GB).
The capacity of a new HDD must be the same as the capacity of the replaced HDD (or larger).
NOTICE
possibility of data loss!
▶
Always replace a defective HDD with a HDD from the same production series with
identical firmware.