19
IPS 10 000 – Firmware Versions 10.7.X| REV. 1.0.0 | © 2021 Dallmeier
HDDs
The appliance is operated with several hard disks and a RAID system.
▶
Proceed as described below, to replace a defective hard disk drive.
6.1
IDeNtIFY
All hard disks are easily accessible on the front side of the device. First, the defective hard disk drive must
be identified. There are two options available for this purpose: via the information dialog or via the dis-
play on the front side of the appliance.
6.1.1
Information Dialog
In the information dialog comprehensive information about the current status of the hard disk drives
(HDDs) are displayed.
▶
Open the
Info
dialog via
System
>
Info
.
▶
Select the
hDD Status
tab.
Fig. 6-1
black
HDD is not mounted
green
HDD is active and OK
red
HDD is defective
yellow
HDD is not active and OK (RAID spare HDD)
orange
HDD is in recovery process (RAID)
▶
Check the status of the hard disk drives.
▶
Identify the defective hard disk drive.