background image

 

W8

www.dallmeier.com 

33

  Fig. 12 

A

  Ceiling/wall mount bracket (thread type: G 1 1/4" DIN ISO 228)

B

  PTFE thread seal tape

C

  Mounting flange

D

  2× Hexagon socket head cap screw (M4 × 6 mm, hex key size: 3)

 

Observe the following instructions.

A

B

D

C

D

Summary of Contents for PANOMERA W8

Page 1: ...006478 1 0 1 2017 02 14 English Commissioning W8...

Page 2: ...rks or registered trademarks of the following owners Google and Google Chrome of Google Inc headquartered in Mountain View California USA JavaScript of Oracle Corporation and or its affiliates headqua...

Page 3: ...4 2 4 1 1 1...

Page 4: ......

Page 5: ...Transportation and Packaging 16 Warranty 16 Appropriate Use 16 Operation 17 Formation of Condensation 18 7 Requirements 20 Ambient Conditions 20 Power Supply 21 8 Maintenance 22 9 Installation and Com...

Page 6: ...on a digital medium Additional information if available is provided exclusively on the website www dallmeier com Read the complete product documentation for the device carefully and thoroughly before...

Page 7: ...target audience of the document is trained system integrators Configuration The document entitled Configuration contains detailed information concerning the configuration of the device The target audi...

Page 8: ...to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfer ence when the equipment is operated in a commercial environment This equipment generates...

Page 9: ...W8 www dallmeier com 9...

Page 10: ...s a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION...

Page 11: ...ed by arrows Always carry out instructions one after the other in the sequence described Expressions in quotation marks generally indicate a control element on the device switches or labels or on its...

Page 12: ...ust be followed Regulations The use of video and audio surveillance systems is in general strictly regulated Inform yourself about the currently valid laws and regulations regarding data worker and en...

Page 13: ...dallmeier com for the latest product documentation updates Condensation Water If the device is brought from a cold to a warm environment resulting condensation water may cause malfunctions and damages...

Page 14: ...the operating condition requirements and the maintenance instructions Foreign Bodies If objects or liquids get into the device immediately disconnect it from the power supply pull out the power plug...

Page 15: ...rew M4 6mm hex key size 3 4 Hexagon socket head cap screw M5 12mm hex key size 4 Product documentation published in print and or on DVD ROM The scope of delivery may differ depending on the ordered eq...

Page 16: ...single location The innovative lens sensor concept of the Panomera W8 in combination with a high resolution fisheye lens allows for the unique capturing of a complete half space half sphere without b...

Page 17: ...e multifocal sensor system thus provides a long service life and long term investment protection at low infrastructural demands The multifocal sensor system Panomera W8 is designed for both indoor and...

Page 18: ...is sioning Pressure Equalization Element The device is equipped with a pressure equalization element Pressure equalization elements are used to prevent the formation of con densation in sealed enclosu...

Page 19: ...ion glasses This phenomenon is due to physical reasons and therefore does not constitute a defect Condensation on the Outside of the Housing Condensation on the outside of the housing may form tempora...

Page 20: ...nctions or damages Do not install operate the device in places with a large amount of dust and dirt with steam or oil vapors e g kitchen with direct sunlight with strong heat emissions e g radiator wi...

Page 21: ...s For the safety of persons protection against dangerous contact voltages and devices protection against lightning strikes and over voltages electrical surges as well as for the immunity of informatio...

Page 22: ...sing outside with a soft dry and antistatic cloth Do not use detergents Do not use microfiber cleaning cloths Clean the lens protection glasses with water and some dishwash ing agent using a soft non...

Page 23: ...manufacturer s instructions about the maximum adequate carrying capacity of the supporting structure For mounting a ceiling wall mount bracket always use screws and anchors that are suitable for your...

Page 24: ...W8 24 www dallmeier com Remove the cover of the accessory tray Fig 2...

Page 25: ...W8 www dallmeier com 25 Remove the included accessories and the product information Fig 3...

Page 26: ...W8 26 www dallmeier com Fig 4 Remove the upper packaging foam insert...

Page 27: ...W8 www dallmeier com 27 Rotate the foam insert by 180 so that the top side is facing down wards as shown in the illustration above Place the foam insert onto a stable and flat surface Fig 5 Fig 6...

Page 28: ...W8 28 www dallmeier com Fig 7 Remove the mounting flange Fig 7 A and the Panomera W8 A Mounting flange A...

Page 29: ...ier com 29 Securely place the Panomera W8 into the rotated foam insert so that the protruding fisheye lens Fig 8 A on the bottom side will not get damaged during the next installation steps Fig 8 A Fi...

Page 30: ...W8 30 www dallmeier com Fig 9...

Page 31: ...dallmeier com 31 Phillips PH1 Fig 10 A 4 Pan head screw with cross recess M4 10mm Phillips PH1 Attach the sunshield packaged separately to the Panomera W8 and secure it with the supplied screws Fig 1...

Page 32: ...W8 32 www dallmeier com Fig 11...

Page 33: ...com 33 Fig 12 A Ceiling wall mount bracket thread type G 11 4 DIN ISO 228 B PTFE thread seal tape C Mounting flange D 2 Hexagon socket head cap screw M4 6mm hex key size 3 Observe the following instru...

Page 34: ...wn in Fig 12 i e clockwise when viewing the thread from below bottom view Then screw the mounting flange completely onto the ceiling wall mount bracket Do not rotate the mounting flange back not even...

Page 35: ...finally mount the Panomera W8 Route the connection cable of the Panomera W8 through the used ceiling wall mount bracket Position the Panomera W8 centered on the mounting flange so that the 4 thread ho...

Page 36: ...W8 36 www dallmeier com Fig 14 A 4 Hexagon socket head cap screw M5 12mm hex key size 4 Assemble the Panomera W8 with the 4 supplied hexagon socket head cap screws Fig 14 A on the mounting flange A...

Page 37: ...le to a suitable network switch Connect the power cables two multi stranded wires with wire end ferrules to a suitable power supply unit observe the chapter Cable Assignment on page 38 Connect the use...

Page 38: ...ular plug male for 1000BASE T 1000Mbps B Power IN black white wire 48V DC C Power IN black wire 48V DC D Heating blue wire and brown wire not used no function Fig 16 The network connection type Fig 16...

Page 39: ...W8 www dallmeier com 39...

Page 40: ...o display evaluate the Panomera streams with SMAVIA Viewing Client the client PC must meet the following system requirements System Requirements Minimum Operating system OS Microsoft Windows 7 Profess...

Page 41: ...each browser Browser settings JavaScript enabled Configuration Steps The configuration of the Panomera multifocal sensor system in conjunc tion with systems for the recording SMAVIA Recording Server...

Page 42: ...and assis tance Start the web browser Enter the IP address of your Panomera multifocal sensor system master module into the address bar of the web browser Confirm the input The connection to the Panom...

Page 43: ...TICE Risk of misuse by unauthorized users Change the default login credentials of the administrator account as soon as possible Enter your login credentials Confirm with OK After the successful login...

Page 44: ...1000BASE T 1000Mbps or Fibre optic cabling MMF Pre assembled fibre optic cable with LC Duplex connector Multimode for 1000BASE SX MMF 850nm 550m 1 805ft or Fibre optic cabling SMF Pre assembled fibre...

Page 45: ...ons on page 46 Weight Approx 12kg 26 5Ibs Environmental Conditions Suitable installation sites Indoor Outdoor Operating temperature 40 C to 50 C 40 F to 122 F minimum start up temperature 30 C 22 F Re...

Page 46: ...W8 46 www dallmeier com 13 Dimensions 356 mm 14 02 109 mm 4 29 219mm 8 62 256mm 10 08 185 mm 7 28 62 mm 2 44 145mm 5 71 Fig 17...

Page 47: ......

Page 48: ...Dallmeier electronic GmbH Co KG Bahnhofstr 16 93047 Regensburg Germany Phone 49 0 941 87 00 0 Fax 49 0 941 87 00 180 www dallmeier com info dallmeier com...