Turn the locking screw of the ball head with the supplied hexagon 
socket screw key (size 5) in counterclockwise direction (beyond a 
noticeable end-stop) until you can tilt the device with your hands in 
all directions with little effort.

Fig. 29

Summary of Contents for Panomera W Series

Page 1: ...007425 REV 2 0 4 2020 11 02 COMMISSIONING W Series...

Page 2: ...llowing owners Google and Google Chrome of Google Inc headquartered in Mountain View California USA JavaScript of Oracle Corporation and or its affiliates headquartered in Redwood Shores California US...

Page 3: ...3 COMMISSIONING Panomera W Series REV 2 0 4 2020 Dallmeier...

Page 4: ......

Page 5: ...eration 16 Remedies at High Ambient Temperatures 17 Formation of Condensation 18 7 Requirements 20 Ambient Conditions 20 Earthing Grounding 21 Power Supply 22 8 Maintenance Inspection and Cleaning 23...

Page 6: ...ious documents which are provided in printed and or digital form as for example via the website www dallmeier com Read the complete product documentation for the device carefully and thoroughly before...

Page 7: ...tem integrators installa tion contractors of video security surveillance systems Configuration The document entitled Configuration contains detailed information con cerning the configuration of the de...

Page 8: ...death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazardous situation which if not avoid...

Page 9: ...instructions one after the other in the sequence de scribed Expressions in quotation marks usually refer to individual components of the device housing parts mounting elements connections interfaces e...

Page 10: ...al device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This e...

Page 11: ...of electrical appliances Periodic inspection on electrical appliances General requirements for electrical safety Regulations The use of video and audio security surveillance systems is in general stri...

Page 12: ...om for the latest product documentation updates Condensation If the device is brought from a cold to a warm environment resulting condensation may cause malfunctions and damage In this case wait until...

Page 13: ...Device If objects or liquids get into the device immediately interrupt the power supply to the device e g switch off the corresponding circuit breaker Contact the sales partner responsible for your a...

Page 14: ...roduct documentation The scope of delivery may differ depending on the ordered equipment device variant or country of destination Transportation and Packaging Store the original packaging for later tr...

Page 15: ...without blind spots i e 360 horizontally and 90 vertically The geometrically correct and almost distortion free display of the surveil lance area linearly scaled in horizontal and vertical direction a...

Page 16: ...istorted The device is equipped with Automatic Gain Control AGC In low light conditions the image may be altered e g noise This is not a malfunction The video image quality depends on the lighting con...

Page 17: ...bient temperatures higher than 30 C and or direct sunlight may result in a reduced image quality due to the following factors Heat Haze Remedy No remedy for this situation possible High Brightness Lev...

Page 18: ...e outside of the housing as well as inside the device In this case wait until the temperature of the device will have slowly adapted to the ambient temperature prior to commissioning Pressure Equaliza...

Page 19: ...e inner surface of the dome bubble as well as on the front glass ele ments of the built in lenses In this case activate the integrated heater manually via the WebConfig user interface of the Panomera...

Page 20: ...longer period of time high heat radiation e g radiator improper ambient temperatures nearby strong radiation sources e g radio transmitters magnetic fields corrosive gases and liquids e g salt water...

Page 21: ...s malfunctions due to electromagnetic interferences Carry out all protective measures for a standard compliant earthing grounding and a correct lightning protection equipotential bonding of the device...

Page 22: ...re connecting or disconnecting a power supply unit make sure that the power supply unit is disconnected from the mains socket pull the power plug out of the socket Carry out all protective measures fo...

Page 23: ...the housing or the polycarbonate dome bubble of the device observe the following notes NOTICE Damage to the surfaces of the device due to improper cleaning practices Clean the outside of the housing w...

Page 24: ...rying capacity of the supporting structure ceiling wall To mount the optionally available Mountera Wall Bracket or Mountera Ceiling Bracket only use screws and if necessary dowels that are suitable fo...

Page 25: ...irit level The device can be mounted on either the optionally available Mountera Wall Bracket or the Mountera Ceiling Bracket The individual mounting steps differ only marginally In the following the...

Page 26: ...REV 2 0 4 2020 Dallmeier Place the device in its original packaging on a level clean and stable surface Open the device packaging Be careful not to damage the original packaging for future transpor ta...

Page 27: ...27 COMMISSIONING Panomera W Series REV 2 0 4 2020 Dallmeier Carefully pull the top foam insert out of the packaging Fig 5...

Page 28: ...ies REV 2 0 4 2020 Dallmeier Carefully pull the device by its plastic handle red out of the pack aging The bottom foam insert has to be lifted out together with the device and must not be removed from...

Page 29: ...installation location and place it together with the bottom foam insert on a level clean and stable surface The bottom foam insert is necessary to prevent the polycarbonate dome bubble on the bottom s...

Page 30: ...lmeier Remove the carrying handle by first bending it slightly apart from one side with your hands and then pulling it off completely Fig 8 Separate the two halves of the remaining cap and then remove...

Page 31: ...31 COMMISSIONING Panomera W Series REV 2 0 4 2020 Dallmeier Fig 10 Place the individual parts of the plastic handle back into the original packaging of the device for later reuse...

Page 32: ...32 COMMISSIONING Panomera W Series REV 2 0 4 2020 Dallmeier Fig 11 Attach the supplied flexible rubber sleeve bellows from the accessory box to the connecting plate of the Mountera Quick Lock System...

Page 33: ...OMMISSIONING Panomera W Series REV 2 0 4 2020 Dallmeier Fig 12 Make sure that the rubber sleeve is correctly seated on all sides to prevent any moisture dust and dirt from penetrating the device later...

Page 34: ...V 2 0 4 2020 Dallmeier Fig 13 Make sure that the locking screw of the Mountera Quick Lock Sys tem is fully open turned in counterclockwise direction For this purpose use the supplied hexagon socket sc...

Page 35: ...e device with the safety cable coming out of the bracket at the provided safety cable fixation point on the outside of the housing secondary safety component as shown in Fig 14 in order to pre vent th...

Page 36: ...omera W Series REV 2 0 4 2020 Dallmeier Before assembling the device to the bracket hold the device so that the adjusting screw of the Mountera Plug is aligned with the lock ing screw of the bracket F...

Page 37: ...straight run the cables coming from the bracket along the rear side of the device Insert the Mountera Plug into the Mountera Lock until the spring mechanism inside the bracket locks into place make su...

Page 38: ...s REV 2 0 4 2020 Dallmeier Fig 17 Secure the Mountera Quick Lock System by turning the locking screw of the bracket fully in clockwise direction For this purpose use the supplied hexagon socket screw...

Page 39: ...39 COMMISSIONING Panomera W Series REV 2 0 4 2020 Dallmeier Fig 18 Remove the bottom foam insert from the device Place the foam insert back into the original packaging of the device for later reuse...

Page 40: ...40 COMMISSIONING Panomera W Series REV 2 0 4 2020 Dallmeier Fig 19 Open the rubber protective cover captive of the housing cover locking screw...

Page 41: ...41 COMMISSIONING Panomera W Series REV 2 0 4 2020 Dallmeier Loosen the housing cover locking screw in counterclockwise direc tion with the supplied hexagon socket screw key size 5 Fig 20...

Page 42: ...42 COMMISSIONING Panomera W Series REV 2 0 4 2020 Dallmeier Fig 21 Turn the housing cover lock ring in counterclockwise direction as far as it will go...

Page 43: ...43 COMMISSIONING Panomera W Series REV 2 0 4 2020 Dallmeier Fig 22 Open the housing cover...

Page 44: ...nent from the safety cable fixation point on the outside of the housing Run the cables coming out of the bracket and the safety cable through the cable entry as shown in Fig 23 Carry out the cabling a...

Page 45: ...Secure the device with the safety cable coming out of the bracket at the provided safety cable fixation point inside the housing secondary safety component as shown in Fig 24 in order to prevent the d...

Page 46: ...46 COMMISSIONING Panomera W Series REV 2 0 4 2020 Dallmeier Close the housing cover Turn the housing cover lock ring in clockwise direction as far as it will go Fig 25...

Page 47: ...a W Series REV 2 0 4 2020 Dallmeier Tighten the housing cover locking screw in clockwise direction with the supplied hexagon socket screw key size 5 Close the rubber protective cover of the housing co...

Page 48: ...MMISSIONING Panomera W Series REV 2 0 4 2020 Dallmeier By default the Mountera Plug is perpendicular to the housing Therefore the device should usually be exactly level to the ground after mounting Fi...

Page 49: ...omera W Series REV 2 0 4 2020 Dallmeier Fig 28 Check whether the device is exactly level to the ground by means of a spirit level If this is not the case follow the instructions described for Fig 29 a...

Page 50: ...Dallmeier Turn the locking screw of the ball head with the supplied hexagon socket screw key size 5 in counterclockwise direction beyond a noticeable end stop until you can tilt the device with your...

Page 51: ...NG Panomera W Series REV 2 0 4 2020 Dallmeier Fig 30 Using a spirit level align the device so that it is exactly level to the ground finally tighten the locking screw of the ball head in clock wise di...

Page 52: ...ignment on page 54 Connect the used power supply unit to the mains socket The device starts and is ready for operation after a few minutes Check the live image of the device on a monitor If necessary...

Page 53: ...l the flexible rubber sleeve bellows over the ring provided on the top of the housing Make sure that the rubber sleeve is correctly seated on all sides to prevent any moisture dust and dirt from getti...

Page 54: ...eries REV 2 0 4 2020 Dallmeier Fig 33 10 Connections and Pin Assignment Important information on the earthing grounding connection can be found in the section Earthing Grounding on page 21 LAN 1 LAN 2...

Page 55: ...In HARTING connector Pin No Assignment Wire Color No Power Cable 1 GND Camera black 2 48V DC Camera black 3 48V DC Heater black 4 GND Heater black Functional Earth green yellow Fig 35 Power cable 5 c...

Page 56: ...with SMAVIA Viewing Client the client PC must meet the following system requirements System Requirements Minimum Operating system OS Microsoft Windows 7 Professional 64 bit with latest service pack Pr...

Page 57: ...er settings JavaScript enabled Configuration Steps The configuration of the Panomera multifocal sensor system in conjunction with systems for the recording SMAVIA Recording Server and display evalu at...

Page 58: ...stem via the Ethernet if necessary con tact your network administrator for more information and assistance Start the web browser Enter the IP address of your Panomera multifocal sensor system master m...

Page 59: ...nt user name admin The default password is the complete serial number of the device The serial number is printed on the type plate of the device and can also be determined using the Dallmeier software...

Page 60: ...name of the factory default administrator account is admin Enter your login credentials Click OK After the successful login the graphical user interface of the configuration mode is displayed Configu...

Page 61: ......

Page 62: ...d with STX RJ45 coupler Cat 6 for 100BASE TX 100Mbps service port Electrical Data Voltage supply Camera 48V DC 5 Heater 48V DC 5 Power consumption Camera Max 80W Heater Max 60W Power In interface HART...

Page 63: ...F to 131 F minimum start up temperature 30 C 22 F Heater On 10 C 50 F Heater Off 10 C 50 F Relative humidity 0 90 RH non condensing Additional Features Ambient light sensor 1 Mechanically removable in...