background image

English

Commissioning

005110 / 2.0.0 / 2017-07-12

S4-S8

Summary of Contents for PANOMERA S4

Page 1: ...English Commissioning 005110 2 0 0 2017 07 12 S4 S8 ...

Page 2: ...of Dallmeier electronic All trademarks identified by are trademarks or registered trademarks of the following owners Google and Google Chrome of Google Inc headquartered in Mountain View California USA JavaScript of Oracle Corporation and or its affiliates headquartered in Redwood Shores California USA Microsoft Internet Explorer Microsoft Edge and Windows of Microsoft Corporation headquartered in...

Page 3: ...te Use 10 6 5 Operation 10 6 6 Formation of Condensation 11 7 Requirements 12 7 1 Ambient Conditions 12 7 2 Power Supply 13 8 Maintenance and Inspection 14 9 Limits of the System 15 10 Installation 16 10 1 Installation on Wall Mount Bracket 17 10 2 Installation on Ceiling Mount Bracket 18 11 Connections 24 12 Configuration 26 12 1 System Requirements 26 12 2 Configuration Steps 28 12 3 Establishin...

Page 4: ...efore using the respective device or software application Always follow the contained instructions notes and warnings and observe the technical specifications in the relevant product data sheet Keep all documents in legible condition and in a suitable location for future reference Regularly check the website www dallmeier com for the latest product documentation updates 2 1 This Document Commissio...

Page 5: ...documentations of the following Dallmeier software applications PService3 SMAVIA Recording Server SMAVIA Viewing Client 3 Approvals Certifications The following approvals certifications were valid for the device at the time of this document s compilation CE FCC ACA DIN 50130 4 compliant Visit www dallmeier com for possible updates Note USA This equipment has been tested and found to comply with th...

Page 6: ...ult in minor or moderate injury NOTICE NOTICE indicates practices for preventing property damage incorrect configurations or faulty operations For reasons of clarity and readability various text formatting elements and types of emphasis are used in this documentation Instructions are indicated by arrows Always carry out instructions one after the other in the sequence described Expressions in quot...

Page 7: ...nents may cause malfunctions damages and data loss and may result in the loss of warranty Modifications Do not make any modifications to the hardware or software that have not been tested and approved by Dallmeier Inappropriate modifications may cause malfunctions damages and data loss and may result in the loss of warranty Documentation The product documentation contains several documents which a...

Page 8: ...mandatory and must be fulfilled by all means Operating Conditions Unfavorable operating conditions may shorten the life of the device and may cause malfunctions damages and data loss and may result in the loss of warranty Observe the specifications given in the technical data the operating condition requirements and the maintenance instructions Foreign Bodies If objects or liquids get into the dev...

Page 9: ...l range of the device depends on the ordered equipment or device variant and may differ from this document s content Certain functions and features may require the purchase of an additional license 6 2 Transportation and Packaging Store the original packaging for later transportation Dallmeier is not responsible for any damage resulting from unprofessional improper transportation The device should...

Page 10: ...matter which part of the surveillance zone an operator focuses at any time Panomera always captures the entire event Therefore an incident can always be reconstructed later to be used as evidence in court regardless of where it happened and it is possible to recognize the individuals involved Panomera enables full overview with minimum wear and nearly no maintenance The multifocal sensor system th...

Page 11: ...vented Condensation Inside the Housing Despite the built in pressure equalization element a sudden drop in temperature e g based on heavy showers or thunderstorms can cause water vapor moisture inside the housing resulting in condensation on the inner surface of the front glass In this case activate the integrated heater manually via the WebConfig user interface of the Panomera master module until...

Page 12: ...n with direct sunlight with strong heat emissions e g radiator with improper ambient temperatures near sources with strong radiation e g radio transmitters magnetic fields with corrosive surroundings e g gases salt water with insufficient air ventilation e g closed cabinet Environmental Conditions Suitable installation sites Indoor Outdoor Operating temperature 40 C to 50 C minimum start up temper...

Page 13: ...tage electrical surge Risk of death or serious injury as well as damage to the device To ensure the safety of persons protection against dangerous contact voltages and to prevent damage to the device caused by electrical surge a standard compliant earthing of the device is mandatory NOTICE Damage to the device resulting from improper power supply Always ensure the correct polarity when using a 48V...

Page 14: ... and sunshield only with a soft dry and antistatic cloth Do not use detergents Do not use microfiber cleaning cloths glasses cleaning cloths abrasive paper towels or cloths with seams buttons plastic or metal parts Damage to the coated front glass due to improper cleaning Clean the coated front glass of the Panomera only with the cleaning components recommended by Dallmeier special glass cleaner a...

Page 15: ...e module transitions each camera module must be optimally focused For this use the Lens Control dialog in the WebConfig user interface of the respective Panomera camera module the automatic calibration of the module transitions is not possible for low contrast scenes In this case place an object with sufficient contrast in the corresponding module area and restart the calibration areas with clearl...

Page 16: ...the supporting structure For the installation of the wall ceiling bracket always use screws and anchors suitable for your wall ceiling type Ensure that the device is adequately secured during installation and operation with the supplied safety wire rope length 1 meter carabiner with screw lock on both ends to prevent it from falling The supplied safety wire rope conforms to the standard BGI 810 3 ...

Page 17: ...g backwards in the direction of the housing backside 10 1 Installation on Wall Mount Bracket Mount the Panomera on the wall mount bracket as shown in the figure above ⓐ Adapter plate already mounted at the factory ⓑ 4 Hexagon socket head cap screw DIN 912 M5 16 ⓒ 4 Washer DIN 125 A5 3 ⓐ ⓒ ⓑ ...

Page 18: ...the top side of the sunshield facing downwards on a clean and stable surface put a soft cloth or similar under the sunshield to avoid scratching its surface coating Unscrew the 4 hexagon socket head cap screws ⓐ and remove the adapter plate ⓑ ⓐ 4 Hexagon socket head cap screw DIN 912 M6 12 ⓑ Adapter plate ⓑ ⓐ ...

Page 19: ...www dallmeier com 19 Commissioning S4 S8 Carefully slide the Panomera out of the sunshield ...

Page 20: ...ing Turn the Panomera so that the top of the housing is facing up again Unscrew the 8 hexagon socket head cap screws ⓐ and remove the 4 plastics rails ⓑ from the housing ⓐ ⓑ ⓐ 8 Hexagon socket head cap screw DIN 912 M6 10 ⓑ 4 Plastic rail ...

Page 21: ...er plate ⓑ with the 4 hexagon socket head cap screws ⓐ onto the top side of the housing The beveled edge of the adapter plate has to point backwards in the direction of the hous ing backside ⓐ 4 Hexagon socket head cap screw DIN 912 M6 12 ⓑ Adapter plate ⓑ ⓐ ...

Page 22: ...22 www dallmeier com S4 S8 Commissioning Mount the Panomera on the ceiling mount bracket as shown in the figure above ⓐ 2 Hexagon head screw M6x12 ⓑ 2 Washer ⓐ ⓑ ...

Page 23: ...www dallmeier com 23 Commissioning S4 S8 ...

Page 24: ...24 www dallmeier com S4 S8 Commissioning 11 Connections ⓐ Earthing grounding connection connecting thread M6 ⓐ ...

Page 25: ...supply of camera and heater with a 48V DC power supply unit optionally available a 4 core cable link is recommended Hirschmann CA 3 GS Data link copper cabling Optional data link fiber optic cabling Hirschmann CA 3 GS mating connector Hirschmann CA 3 LD Pin GND 48V DC Camera Pin 3 48V DC 24V AC Heater Pin 1 48V DC Camera Pin 2 48V DC 24V AC Heater ...

Page 26: ... system and to display evaluate the Panomera streams with SMAVIA Viewing Client the client PC must meet the following system requirements System Requirements Minimum Operating system OS Microsoft Windows 7 Professional 32Bit with latest service pack Processor CPU 2 66GHz Dual Core Random access memory RAM 2GB DDR3 Graphics card 1 NVIDIA GeForce GTX 1070 Ethernet 1000Mbps Gigabit Network Web browse...

Page 27: ... 64Bit with latest service pack Processor CPU 3 6GHz Quad Core Random access memory RAM 8GB DDR3 Graphics card 1 NVIDIA GeForce GTX 1070 2 NVIDIA GeForce GTX 950 Ethernet 1000Mbps Gigabit Network Web browser Microsoft Edge Google Chrome Mozilla Firefox latest available version of each browser Browser settings JavaScript enabled ...

Page 28: ... context also note the descriptions in the Panomera documentation Configuration Quick Guide 12 3 Establishing the Connection Panomera WebConfig Ensure that your PC web browser can establish a connection to your Panomera multifocal sensor system via Ethernet if necessary contact your network administrator for more information and assistance Start the web browser Enter the IP address of your Panomer...

Page 29: ...rd 3 NOTICE Risk of access and misuse by unauthorized users Change the default login credentials of the administrator account as soon as possible Enter your login credentials Confirm with OK After the successful login the graphical user interface of the configuration mode is displayed Configure all required settings Finally click LOGOUT to log out of the Panomera multifocal sensor system Detailed ...

Page 30: ...cal Data Construction material Aluminum Finish Powder coating grey white RAL 9002 Weight with sun shield approx 12 5kg 27 6lbs Environmental Conditions Suitable installation sites Indoor Outdoor Operating temperature 40 C to 50 C minimum start up temperature 30 C Heater On 10 C Heater Off 10 C 40 F to 122 F minimum start up temperature 22 F Heater On 50 F Heater Off 50 F Relative humidity 0 90 RH ...

Page 31: ...com 31 Commissioning S4 S8 14 Dimensions 305mm 12 01 185 mm 7 28 370mm 14 57 185 mm 7 28 320mm 12 60 16mm 0 63 370 mm 14 57 305mm 12 01 0 8 46 57 97 113 116 137 85 0 31 35 31 35 6 M5 4 DIN74 Km6 2 M6 mm Adapter plate ...

Page 32: ...Notes ...

Page 33: ...Notes ...

Page 34: ......

Page 35: ......

Page 36: ...Dallmeier electronic GmbH Co KG Bahnhofstr 16 93047 Regensburg Germany Phone 49 941 8700 0 Fax 49 941 8700 180 www dallmeier com info dallmeier com ...