DF4510HD | DF4910HD | DDF4510HDV-IM/-SM | DDF4910HDV-IM/-SM
www.dallmeier.com
16
LAN / PoE
(RJ45 jack)
Power IN (12 V DC)
Weidmüller male connector
SL 3.50/02/90G
Audio OUT / Micro IN
(3.5 mm phone jack)
Power LED
Video preview output
(BNC, CVBS)
DC auto iris interface
for iris control
LAN LED
SDHC
card slot
Fig. 5-2
Notice
For a clean (interference-free) audio signal transmission, the Audio IN/OUT
Y-Cable Connector FGA-30 is required (optionally available).
LAN LED Status
Red LED (constant): Boot sequence is running (but no encoder is running yet);
Critical error during update (
see below
)
Green LED (constant): Encoding active (Red LED off)
Green LED (blinking): Streaming of encoded data active
The following LED states will occur during a successful update process:
Start of update process: All LEDs off
While update is running and during the critical phase: Red LED (blinking)
After successful update process until restart of system (5 – 10 sec.): Green LED
System restart: All LEDs off
Important:
If the update process has failed or the update was only partially executed, the Green LED
phase will NOT occur.
Instead, the Red LED is illuminated until the restart of the system (5 – 10 sec.).