82
|
Dali Matrix PS System Installation and Commissioning Guide
Dali Wireless Proprietary and Confidential | DW-MAN-036 Rev 06
To ground the unit:
1. Use a #2 Phillips screwdriver to remove the ground lug.
2. Insert #10 AWG ground wire into the ground lug and crimp.
3. Reattach the ground lug to the remote and tighten both screws.
4. Use a zip tie or other fastener to secure the ground wire to a post or other cable
management.
5. Run the ground wire to the facility grounding point and secure it.
6.6
Connecting DC Power
The airHost PS and remote type 2 units require an uninterrupted 48 VDC power supply.
There are two options for connecting power:
Connect DC power directly to the unit from the fuse panel using the DC power
connector and cable.
Use the Matrix AC/DC power supply if the power source is AC power
6.6.1
Option 1: Using a DC Power Connector and Cable
If the power source equipment is supplying DC power, use a DC cable at a suitable
gauge given the distance from the fuse panel to the remote, and assemble the provided
DC power connector onto the cable.
To assemble the DC power cable, see
Assembling and Connecting the DC Power
Figure 6-12: DC Power Connector