DALEMANS sa/nv
Rue Jules Mélotte 27A
B-4350 Remicourt
+32 19 33 99 43
U•V6
Instruction Manual
28
|
65
Certified
ISO9001 • VCA
Switch to battery
Switch to battery ?
The user can confirm their request to switch power sources by pressing
ENTER
.
Switch to battery
Switched to battery
The U•V6 unit then reacts as if it were powered by the battery only:
▪
The
POWER
LED turns off
▪
The
BATTERY
LED lights up, but the power fault is not activated, i.e. the
FAULT
LED stays off.
This transition to battery-power operation is ended by one of the following:
▪
the user pressing
ESC
▪
the menu idle time expiring.
Calibration Age Examples:
Parking 1
154 days
Parking -1
Disabled
Date and Time
The date and time of the U•V6 unit are stored in Non-Volatile memory. They are only
updated when the unit is powered.
If the date or time of the U•V6 unit is incorrect, the user can press
ENTER
on the keyboard
to enter edit mode.
▪
Edit Date & Time
appears
▪
The cursor flashes on the value to be modified in the date or time field:
Date & time setting
dd/mm/yyyy hh:mm
The user can change the field to be modified using the
Right
and
Left
arrow keys:
The user can change the value in the selected field using the
Up
and
Down
arrow keys.
Once the date and time has been updated, the user can confirm the modification by
pressing
ENTER
.