![DALCNET DGM02 Device Manual Download Page 11](http://html1.mh-extra.com/html/dalcnet/dgm02/dgm02_device-manual_3281305011.webp)
DGM02
Device Manual
Made in Italy
DALCNET S.r.l.
36077 Altavilla Vicentina (VI)
–
Italy
Via Lago di Garda, 22
Tel. +39 0444 1836680
–
Rev.
06/12/2022 -
Pag.
11/32
SECTION: BUS CONFIGURATION
B
US
1
BUS 1 is related to the first RS485 port.
You can set this port in the following configurations:
Not Set
RS485 MODBUS RTU master
RS485 MODBUS RTU slave
DMX512 master
DMX512 slave
In this menu it is possible to assign the "OFFSET" and the "CHANNELS RANGE" to the BUS
1 channels.
The OFFSET allows you to assign the number of the starting slide to the first channel of BUS
1.
The CHANGE RANGE allows you to set the number of channels you want to use in BUS 1.
The BUS can be disabled by means of the “MUTE” flag or by setting the bus configuration in
“NOT SET”.
B
US
2
BUS 2 is related to the second RS485 port.
You can set this port in the following configurations:
Not Set
RS485 MODBUS RTU master
RS485 MODBUS RTU slave
DMX512 master
DMX512 slave
In this menu it is possible to assign the "OFFSET" and the "CHANNELS RANGE" to the BUS
2 channels.
The OFFSET allows you to assign the number of the starting slide to the first channel of BUS
2.
The CHANGE RANGE allows you to set the number of channels you want to use in BUS 2.
The BUS can be disabled by means of the “MUTE” flag or by setting the bus configuration in
“NOT SET”.