Adjustments
Wheels
The wheel bearing must be lubricated and adjusted once a year. Also make sure you
have the correct tyre pressure (see tyres).
Adjustments of lubrication and wheel bearings
1.
Hub cap is removed.
2.
The cotter is removed.
3.
The castellated nut is tightened with a 1/6 turn, so that the hole is aligned with
the shaft. The wheel is spun around and there should be no resistance. Only a
little bit of slack should be felt in the hub housing when the wheel is moved from
side to side. If there is too much slack, repeat the process.
4.
The cotter is installed.
5.
The hub cap is filled 3/4 with grease and fitted.
Worn out parts
Fig. 9
The factory blades are fitted with a
protective sheet (A) between each to
save the bolts and containers. The
blades can be replaced as necessary,
with 2 knives installed per row of every
one of the 2 roller bearings.
Blade drums
The containers must be protected against frost deformation/bursting. This can be done
by storing the machine in a frost-free environment or by emptying the drums of water
before cold weather. Failure to do this can lead to a risk of the rollers being destroyed.
It is also possible to add antifreeze to the water in the drums. Follow the recommended
mixing ratio from the manufacturer of the antifreeze.
Hydraulics
All hydraulic hoses must be checked for wear or damage. Ensure the hoses are not
subjected to any crushing.
If left parked for longer periods of time, protruding plunger rods should be greased with
oil or pressure grease, in order to avoid the build-up of rust on the plunger rod.
Remember to remove it again before use.