TRIMAX Plus
Page 22
Hydraulics
Check all hydraulic hoses for wear or cracks. Check all hoses for crimping.
Lubricate exposed rams with oil or pressure-resistant grease to avoid rust
forming when storing for long periods. Remember to remove before use.
Plate hubs
Tighten plate hubs once annually or as required.
Fig. 11
1.
Remove plate.
2.
Remove split pin in hub nut.
3.
Tighten hub nut a ¼ turn or
until there is no slack in the
hub.
Wear parts
The tines on TRIMAX Plus are reversible, and must be turned before wear
occurs on the retaining bracket.
Replace the wings when the wear is sufficient to cause unsatisfactory results,
or before wear occurs on the retaining bracket.