Galaxy GS6 Display Internal Connection
Conversion Quick Guide
1 May 2017
DD3497847
Rev 02
201 Daktronics Drive Brookings, SD 57006
www.daktronics.com/support
800.325.8766
Page 1 of 2
Use this procedure to convert the external J-box
and quick-connect plates on
a Galaxy
®
GS6 display to
internal locations. Complete
these steps when mounting
GS6 displays flush on a
building or structure or when
two displays are mounted
back-to-back in a closer
configuration than the
standard back-to-back
mounting kit allows.
Required Tools
• Hex Head Wrench
• Channel Lock or
7
/
16
″
socket
• Phillips Head Screw Driver
Moving the Quick
Connect Plates
1. Remove two bottom-left modules to access
the Primary display input quick-connect plate.
2. Remove two bottom-right modules to access
the mirror input/output quick-connect plate.
3. Remove the three screws that hold the quick-
connect plate to display backsheet. Save the
screws for reuse.
4. Remove the black grommet from the quick-
connect plate.
.438" Required
For Hardware x 2
Standard Back-To-Back
Configuration
Converted Back-To-Back
Configuration
Converted Flush Mount
Configuration
Cabinet
Face-to-Face
Dimension = 14"
Cabinet
Face-to-Face
Dimension >= 11"
Figure 1:
Primary Input
Quick-Connect Plate
Figure 2:
Mirror Input/
Output Quick-Connect
Plate
5. Rotate the quick-connect plate on the
backsheet so the quick connects are located
inside the cabinet.
6. Secure the plate
with the screws
removed in Step 3.
7. Thread the cables
through grommet
and into cabinet.
8. Snap the grommet in
place on outside of
display’s backsheet.
Figure 3:
Input Quick-
Connect Plate Inside
Cabinet
Figure 4:
Mirror Input/
Output Quick-Connect
Plate Inside Cabinet