The operating temperature range (outdoor temperature) is 18 - 43°C for cooling
and -7 - 24°C for heating operation.
CAUTION
• Do not install the air conditioner at any place where there is a danger of flammable gas leakage.
In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.
• While following the instructions in this installation manual, install drain piping to ensure proper drainage and insulate
piping to prevent condensation.
Improper drain piping may result in indoor water leakage and property damage.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.
• Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small animals.
Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around the
unit clean.
• This appliance is intended to be used by expert or trained users in shops, in light industry and on farms,
or for commercial and household use by lay persons.
• Sound pressure level is less than 70 dB(A).
• NOTE: Motor ground only applies to the iron shell motor.
• This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children shall be supervised to ensure that they do not play with the appliance.
Indoor side DB/WB(°C)
Outdoor side DB/WB(°C)
Maximum cooling
32/23
43/26
Maximum heating
27/-
24/18
Working temperature range