Wired Remote Controller
ACCD_WC2
3
2.2 Function of the Buttons
Table 2
No.
Name
Function
1
Enter/Cancel
Function selection and cancellation.
2
▲
①
Running temperature setting of the indoor unit, range:16~30
℃
(61~86°F).
②
6
Timer setting, range:0.5-24 hr.
▼
3
Fan
Setting of the high/middle/low/auto fan speed.
4
Mode
Setting of the Cooling/Heating/Fan/Dry/Auto mode of the indoor unit.
5
Function
7
Switchover among the functions of Turbo
/
Save/E-heater/Blow etc..
Timer
Timer setting.
8
On/Off
Turn on/off the indoor unit.
4+2
▲+Mode
3
+6
Fan+▼
Press them for 5s under off state of the unit to Enter/Cancel the Memory
function(If memory is set, indoor unit after power failure and then power
recovery willresume the original setting state. If not, the indoor unit is
defaulted to be off after power recovery. Memory off is default before
delivery.).
2
+6
▲+▼
By pressing them at the same time under off state of the unit, will be
displayed on the wired remote controller for the cooling only unit, while
will be displayed on the wired remote controller for the cooling and heating
unit.
4+6
Mode+▼
Upon startup of the unit without malfunction or under off state of the
unit,press them at the same time for 5s to enter the lock state, in which
case, any other buttons won’t respond the press. Repress them for 5s to
quit this state.
5+7
Under OFF state, the Celsius and Fahrenheit scales can be switched by
FTimer
①
Indoor ambient temperature is sensed by the return air temperature
sensor ( 01 displayed on the timer area).
②
displayed on the timer area).
③
Under OFF state, it is available to go to the commissioning status by
the temperature display area by pressing “Mode”, then adjust the options
which is shown on the timer area by pressing
“▲”
and
“▼”.
There are totally
four options, as follows:
Indoor ambient temperature is sensed by the wired controller (02
The return air temperature sensor is selected under the cooling, dry, or
④
fan mode; while the wired controller temperature sensor is selected under
the heating or auto mode. (03 is displayed on the timer area).
The wired controller temperature sensor is selected under the cooling,
5+7
dry, or fan mode; while the return air temperature sensor is selected under
the heating mode. (04 is displayed on the timer display area).
FTimer
Under OFF state, it is available to go to the commissioning status by
pressing “Function” and “Timer” for five seconds. Press “Mode” button to
until “01” icon is shown at the temperature display area. The setting status
will be shown at timer area. Press “
▲
” and “
▼
” button to adjust and two
options are available:
①
Three low levels (01) ;
②
Three high levels (02).