background image

Indoor PIR
with Image Transmission

Summary of Contents for SH195AX

Page 1: ...Indoor PIR with Image Transmission ...

Page 2: ... 2 Preparation 95 3 Recognition programming 97 3 1 Programming for recognition by the control panel 97 3 2 Programming for recognition by the standalone dialler 99 4 Parameter setting 101 4 1 Setting the parameters of detector SH195AX 101 4 2 Setting the parameters of detector SH196AX 101 4 3 Parameter setting procedure 102 5 Installing the detector 103 5 1 Choosing the best place 103 5 2 Fixing t...

Page 3: ...coat see table below Animal coat Long hair Short hair Weight W More than 25 kg detector cannot be used detector cannot be used detector cannot be used 20 kg W 25 kg detector can be used detector cannot be used detector cannot be used 12 kg W 20 kg detector can be used detector can be used detector cannot be used Below 12 kg detector can be used detector can be used detector can be used IMPORTANT i...

Page 4: ...deo confirmation of intrusion to a remote monitoring centre a mobile phone in MMS format On receipt of the sequence it is possible to visually check what has really happened on the premises where the alarm was triggered as soon as the information is received When the system is fitted with a standalone dialler powered by the mains or if the control panel is fitted with a transmission module powered by...

Page 5: ... in flash is limited to 7 m maximum The infrared detection protects rooms at risk living room parents bedroom etc according to a 90 angle over a distance of 12 m The optical field corresponds to the view of the built in camera according to an angle of 90 with a range of up to 12 m Front view Test button Detection lens Test LED behind lens MicroSD card supplied compartment ƒ Night lighting flash Rem...

Page 6: ...he lithium power pack supplied in its compartment making sure it is the right way round The red LED behind the lens lights up for roughly 2 s it is normal for the red LED to constantly flash when the detector is not clipped on to its base IMPORTANT If the red LED does not light up when the power pack is connected check the pack is properly positioned If the red LED flashes very quickly when the pac...

Page 7: ... programmed for recognition either by the control panel intrusion event management the control panel fitted with the transmission module intrusion event management and image transmission For the transmission of image sequences via a standalone dialler the detector must first be programmed for recognition by the control panel intrusion event management and then by the standalone dialler image transmi...

Page 8: ...trol panel confirms recognition programming and the red LED on the detector lights up twice for 2 s to 1 To perform detector recognition programming the control panel must be in installation mode If it is not ask the user to enter then installer code factory 1111 beep installation mode master code factory 0000 then detector X group time delay beep detector X group Y immediate IMPORTANT During reco...

Page 9: ...on by the control panel intrusion event management and the standalone dialler image transmission Programming image transmission motion detectors up to 40 to be recognised by the dialler is only possible if the alarm control panel has been programmed for recognition by the dialler The number is automatically allocated by the dialler during recognition programming For example the same detector canno...

Page 10: ...anel and any radio relay units 10 s max Press then on the dialler keypad Press and hold the test button until the dialler responds The red LED on the detector lights up twice for 2 s The dialler issues a voice message to confirm detector recognition programming then DIALLER DIALLER detector X 2 Perform the following recognition programming sequence 3 Check recognition programming Press and hold th...

Page 11: ...4 2 Setting the parameters of detector SH196AX Function description Parameter n Parameter value Characteristics Test LED lighting 1 2 1 Deactivated factory configuration 2 Activated Sensitivity level setting 3 1 Level 1 standard sensitivity factory configuration 2 Level 2 average sensitivity 3 Level 3 high sensitivity 4 Level 4 maximum sensitivity Alarm level 4 1 Intrusion factory configuration 2 ...

Page 12: ...he sensitivity level can be To start the sequence press and hold the button until the LED goes out Press the button 1 2 3 4 6 or 7 times to select the parameter Press and hold the button until the LED goes out and then lights up again Press the button 1 to 4 times according to the chosen parameter value To end the sequence press and hold the button until the LED goes out 1 2 3 4 6 or 7 1 to 4 roug...

Page 13: ...rds the sun or reflective surfaces floor tiles mirror etc as the images picked up by the camera would be overexposed white pointing towards a moving object curtains blinds etc pointing towards the outside of the home or placed in a draught directly on to a metal wall or close to sources of interference electricity meters etc opposite stairs accessible to pets so that it does not detect these pets in...

Page 14: ...he chosen location mark the position of the screws and drill the holes in the wall 2 Insert a long stemmed screw via the rear of the back plate and fix the back plate 3 Position the back plate cover 4 Assemble the two parts of the swivel bracket 5 Insert the assembled swivel bracket into the long stemmed screw 6 Position the motion detector base 7 Tighten the locking screw just enough to be still a...

Page 15: ...t is advisable to move at least 2 m away from the transmission device in order to do this To ensure radio link reliability over time each radio link must be carefully checked once all the products have been installed Proceed as follows beep intrusion detector X 1 Transmission device in installation mode 3 The transmission device performs the test the test is positive the transmission device issues...

Page 16: ...g Detection occurs the 2nd time the beam is crossed 2 2 m h 0 12 m d 6 4 Testing the optical field in the daytime or in low lighting conditions It is important to make sure that the optical field test works If it does not loosen the screw and tightening washer and adjust detector orientation 1 Briefly press the detector test button twice until the red LED flashes rapidly behind the lens 2 Move in fro...

Page 17: ...age when the system is disarmed or armed as indicated in the table below 7 2 Changing the battery The control panel indicates a detector battery fault by issuing the voice message fault voltage detector X To check whether the detector lithium power pack is faulty press the detector test button IMPORTANT if the red LED does not light up when the test button is pressed the lithium power pack needs r...

Page 18: ...d or a remote keypad to enter master code installer code installer code beep disarmed The lithium power pack must be replaced with the same type of pack offering the same characteristics i e 4 5 V 3 Ah We advise you to use a DAITEM BatLi30 power pack available in the catalogue in order to guarantee equipment reliability and individual safety Dispose of the flat power pack in a lithium battery recy...

Page 19: ...cond image sequence Remote monitoring centre film format 10 second film with 1 image second Flash range up to 7 m at 0 lux Type of fixing on swivel bracket Use indoor Power supply BatLi30 lithium power pack 4 5 V 3 Ah manufactured on 10 2012 or later Battery life 5 years 5 image transmissions intrusion per year 10 image sequence requests per month LED 1 Operating temperature 0 C to 55 C Anti tamper p...

Page 20: ...01 489 1 V1 8 1 X X FR 13 Document non contractuel soumis à modifications sans préavis DICHIARAZIONE DI CONFORMITÀ Fabbricante Hager Security SAS Indirizzo F 38926 Crolles Cedex France Tipo di prodotto Rivelatore di movimento Modello depositato Daitem Dichiariamo sotto la nostra responsabilità che i prodotti cui questa dichiarazione si riferisce sono conformi ai requisiti essenziali delle seguenti...

Page 21: ...oduktverbesserungen bleiben uns ohne Ankündigung vorbehalten Nachdruck auch auszugsweise nur mit ausdrücklicher Genehmigung des Herstellers DECLARACION DE CONFORMIDAD Fabricante Hager Security SAS Dirección F 38926 Crolles Cedex Francia Tipo de producto Sensor de movimiento Marca Daitem Declaramos bajo nuestra sola responsabilidad que los productos a los cuales se refiere esta declaración son confo...

Page 22: ... 489 1 V1 8 1 X X GB 13 Non binding document may be modified without prior notice GELIJKVORMIGHEIDSVERKLARING Fabrikant Hager Security SAS Adres F 38926 Crolles Cedex France Soort product Bewegingsdetector Merk Daitem We verklaren op eigen verantwoordelijkheid dat de producten waarop deze gelijkvormigheidsverklaring betrekking heeft beantwoorden aan de fundamentele voorschriften van de volgende ri...

Page 23: ...113 ...

Page 24: ...114 ...

Page 25: ...115 ...

Page 26: ...805295 B 07 2013 ...

Reviews: